Concrete Single Skinned Panels

  1. Stack-Loaded Systems

    • Dowelled together one on top of another and tied back at each floor level
      • Punched Window
        • Single Panel - Punched window
        • Multipanel - Punched window
      • Spandrell and Mullion
        • Standard Post & Beam
      • Freeform and Curves
  2. Floor-by-Floor systems

    • Independant panels supported at each floor level allowing variation
      • Ribbon
        • Spandrell Only
      • Spandrell and Mullion
        • Offset Post & Beam
        • Standard Post & Beam
      • Punched Window
        • Multipanel - Punched window
        • Single Panel - Punched window
          • Portrait Panel
            • a) Standard = 3.23m b) stepped Trailer = 3.68m c) Low Loader trailer = 3.93m
            • Tall Panels that need to be twisted
              • Additional Sockets and turning Shoe required
            • Cladding Support at Midspan of slab edge
              • Stiffen Sab edge design
            • Soft Joint - 2 beads of mastic sealant against closed cell PE foam chords or backing rods
            • Top Joint
              • Raised floor zone - projecting stainless steel box fillet is primary support for cladding and requires 175mm (typical) or upto 225mm (Heavy Duty)
              • Joint above SSL - projection of billet needs to be added to panels overall height
            • Bottom Joint
              • Suspended ceiling zone - requires vertical slot in bracket and slip washers. Stud legnth can be allow for wider cavities readily increased to
              • Joint below slab - minimum edge distance of 100mm to top of pael should be mantained - retraint bracket to become longer
            • Cavity width
              • 50mm width and 250mm wall build up
                • higher insulation material equired as narrow cavity, but acoustic/firestopping material is minimised
              • 100mm width and 225mm wall build up
                • specially fabricated angles cast onto slab edge. Retraint bracket has smaller fixing plate but increased thickness and bolts
              • 150mm width and 250mm wall build up
                • Recess anchor channels into pockets at intervals along slab edge. ALso deeper pocket in slab edge with complicated brackets
          • Landscape Panel
            • Soft Joint - 2 beads of mastic sealant against closed cell PE foam chords or backing rods
            • a) Standard = 3.23m b) stepped Trailer = 3.68m c) Low Loader trailer = 3.93m
            • Cladding Support at Midspan of slab edge
              • Stiffen Slab edge
      • Freeform and Curves
  3. Wall Build up of both systems

    • Cast on Facing Materials
      • Brick = 50mm
      • Natural stone
        • Limestone/sandstone = 50 mm
        • Hard Limestones = 30mm
        • Granite = 20mm
    • Core Concrete Panel thickness determenid through storey height
      • <3300mm high = 150mm thick
      • <3800mm high = 175mm thick
    • U value
      • U = 0.27 w/M2K = 75mm
      • U = 0.2 w/M2K = 100mm