  1. Heating

    • Radiators
      • key points
        • simple and compact
        • Occupants familiar with function
        • low maintianance
        • good temp control
        • range of styles = flexible to layouts
      • limitations
        • slow thermal response
        • heat output is convective
          • can lead to uneven temperature gradient in the space
        • furniture must be positioned sympathetically to avoiding obstructing the heat output
        • the combination of windows that can be opened and perimeter radiators can result in excessive heat loss if the windows are poor design
      • Used in naturally ventilated building
      • located around perimeter walls
        • offset cold down drafts from glazing and prevent condensation forming on glass
      • temperature control achieved through thermostatic radiator valves (TRVs)
        • individual and local control
      • two basic types
        • pressed steel panel
        • cast extruded type - normally alluminium
    • Convectors
      • Key points
        • quicker warm up times in comparison to radiators
        • fan convectors provide high heat output for the unit size
        • convection current by unit provides good air movement
        • fan convectors provide greatly enhanced heat output and air movement
        • the casing can reduce the risk of burning which can occur with radiators
      • Limitations
        • Dust/dirt collects in the casing which required periodic cleaning
        • trench convectors tend to accumulate dirt an the grille can become covered by furniture
        • fan convectors incorporate many components and lack the simplicity of radiators and natural convectors
        • require a power supply
      • Natural convectors
        • casing with top and bottom openings
        • Enter text here
    • Radiant Heating
    • Warm air unit
    • boilers
  2. Ventilation

  3. Air-conditioning

    • introduction to Air con systems
    • Constant volume (CV)
    • Variable air volume (VAV)
    • Displacement ventilation
    • fan coils
    • chilled beams
    • chilled ceilings
    • Room-based heat pumps
    • split systems
    • Variable refrigerant flow systems (VRF)
    • Chillers, dry coolers and cooling towers
  4. Controls

Información