¡GoConqr estrena diseño! Cuéntanos qué te parece.

Test

Unit 203 Revision Question Bank No.2

Usuario eliminado 40 preguntas Actualizado el 24 ene 2019

Hacer el test

Preguntas del test (40)

  1. 1If a steel wire armoured cable had an overall diameter of 16mm what would be the maximum spacing of clips on a horizontal runImagen de la pregunta 1
    1. A250mm
    2. B450mm
    3. C400mm
    4. D0.5m
  2. 2If Band 1 and Band 2 circuits are run through the same trunking what special requirements must you achieve?Imagen de la pregunta 2
    1. ACables to be run in the opposite direction
    2. BCables are installed in separate compartments
    3. CAre not permitted in Trunking
    4. DMust be able to carry the same colour Live and Neutral conductors
  3. 3If the ambient temperature increases the copper cable will Imagen de la pregunta 3
    1. AIncrease resistance
    2. BDecrease resistance

    3. CStay the same
    4. DWill melt
  4. 4If the distance of an interactive whiteboard is 2m and the measurement taken is 4cm what is the scale of the drawingImagen de la pregunta 4
    1. A1:20


    2. B1:100
    3. C1:40
    4. D1:50
  5. 5If the distance of a wall is 4m and the measurement taken by the drawing is 4cm what is the scaleImagen de la pregunta 5
    1. A1:75

    2. B1:100
    3. C1:50
    4. D1:20
  6. 6In electrical systems, the definition of isolation is:
    Imagen de la pregunta 6
    1. APlacing conductors from each circuit in separate conduit
    2. BProtecting each circuit by a separate circuit breaker
    3. CCutting off electrical energy from every power source

    4. DIsolating circuits & equipment from the general mass of earth
  7. 7In order to determine types of materials and quantities required to complete an electrical installation, an estimator will require:Imagen de la pregunta 7
    1. AOperating sheets & manufacturers' models
    2. BExploded view diagrams & data sheets
    3. CA technical drawing & data sheet
    4. DSpecification & wiring diagram

  8. 8For large number of computers installed on a large [LAN] network, what cable would you use?Imagen de la pregunta 8
    1. ASteel wired armour

    2. BFibre optics
    3. CPVC
    4. DMICC
  9. 9On a construction site the voltage to be used for power tools is restricted to Imagen de la pregunta 9
    1. A110V AC
    2. B230V AC

    3. C110V DC
    4. D55V AC
  10. 10On site, where a crane is operating overhead, in addition to a safety helmet an electrician should wearImagen de la pregunta 10
    1. AFace mask
    2. BA high visibility jacket
    3. CRubber soled shoes
    4. DA donkey jacket