O GoConqr está de visual novo! Conte para nós o que você achou.

Quiz

Unit 203 Revision Question Bank No.2

Usuário eliminado 40 perguntas Atualizado em 24 jan 2019

Fazer o quiz

Perguntas do quiz (40)

  1. 1If a steel wire armoured cable had an overall diameter of 16mm what would be the maximum spacing of clips on a horizontal runImagem da pergunta 1
    1. A250mm
    2. B450mm
    3. C400mm
    4. D0.5m
  2. 2If Band 1 and Band 2 circuits are run through the same trunking what special requirements must you achieve?Imagem da pergunta 2
    1. ACables to be run in the opposite direction
    2. BCables are installed in separate compartments
    3. CAre not permitted in Trunking
    4. DMust be able to carry the same colour Live and Neutral conductors
  3. 3If the ambient temperature increases the copper cable will Imagem da pergunta 3
    1. AIncrease resistance
    2. BDecrease resistance

    3. CStay the same
    4. DWill melt
  4. 4If the distance of an interactive whiteboard is 2m and the measurement taken is 4cm what is the scale of the drawingImagem da pergunta 4
    1. A1:20


    2. B1:100
    3. C1:40
    4. D1:50
  5. 5If the distance of a wall is 4m and the measurement taken by the drawing is 4cm what is the scaleImagem da pergunta 5
    1. A1:75

    2. B1:100
    3. C1:50
    4. D1:20
  6. 6In electrical systems, the definition of isolation is:
    Imagem da pergunta 6
    1. APlacing conductors from each circuit in separate conduit
    2. BProtecting each circuit by a separate circuit breaker
    3. CCutting off electrical energy from every power source

    4. DIsolating circuits & equipment from the general mass of earth
  7. 7In order to determine types of materials and quantities required to complete an electrical installation, an estimator will require:Imagem da pergunta 7
    1. AOperating sheets & manufacturers' models
    2. BExploded view diagrams & data sheets
    3. CA technical drawing & data sheet
    4. DSpecification & wiring diagram

  8. 8For large number of computers installed on a large [LAN] network, what cable would you use?Imagem da pergunta 8
    1. ASteel wired armour

    2. BFibre optics
    3. CPVC
    4. DMICC
  9. 9On a construction site the voltage to be used for power tools is restricted to Imagem da pergunta 9
    1. A110V AC
    2. B230V AC

    3. C110V DC
    4. D55V AC
  10. 10On site, where a crane is operating overhead, in addition to a safety helmet an electrician should wearImagem da pergunta 10
    1. AFace mask
    2. BA high visibility jacket
    3. CRubber soled shoes
    4. DA donkey jacket

Informações

Descrição
C&G 2365 Level 2 Unit 203 Revision (Bank 2) OB
Autor
Usuário eliminado
Idioma
English
Visualizações
128
Histórico
Criado em 24 jan 2019 · atualizado em 24 jan 2019

Fale Conosco

Sobre o que é sua mensagem?

O que você acha do novo visual?

Você gostou?