¡GoConqr estrena diseño! Cuéntanos qué te parece.

Test

Gas Anaylzers

Usuario eliminado 7 preguntas Actualizado el 25 ago 2016

Hacer el test

Este test tiene tipos de pregunta que se abren en el reproductor de siempre.

Preguntas del test (7)

  1. 1Gas Chromatography (Absorption Type) NEED TO ADD THIS [blank_start]QUESTION BACK[blank_end]
    1. AQUESTION BACK
  2. 2Advantages: Analyzes [blank_start]many gases[blank_end] at once. Very accurate
    Disadvantages: Requires more [blank_start]time[blank_end] than other analyzers.
    Affected by: [blank_start]H2O[blank_end] and [blank_start]CO2[blank_end]
    Measures: [blank_start]Ne[blank_end], [blank_start]O2[blank_end], [blank_start]N2[blank_end], [blank_start]CO[blank_end]
    1. ACO
    2. BN2
    3. CO2
    4. DNe
    5. ECO2
    6. FH2O
    7. Gtime
    8. Hmany gases
  3. 3CO2/CO/CH4

    AKA: [blank_start]Infrared[blank_end] Absorption Analyzer
    Quick response time is suitable for [blank_start]DLCO[blank_end]
    Calibrate: to room air ([blank_start]0[blank_end]%) and known concentration (.[blank_start]3[blank_end]%) CO then re-zero and use [blank_start]gain[blank_end] to match read out to [blank_start]known[blank_end] concentration.
    Changes in altitude do [blank_start]NOT[blank_end] affect readings.
    1. AInfrared
    2. BDLCO
    3. C0
    4. D3
    5. Egain
    6. Fknown
    7. GNOT
  4. 4Helium analyzer

    Also Known as: [blank_start]Thermal[blank_end] Conductivity or [blank_start]Wheatstone[blank_end] Bridge
    Measures: Gas [blank_start]percentage[blank_end]
    Calibration: To room air ([blank_start]0[blank_end]%) and known ([blank_start]10[blank_end]%) then use gain to adjust to [blank_start]known[blank_end] amount.
    Do not use with [blank_start]flammable[blank_end] gases.
    Used with Helium dilution tests.
    1. AThermal
    2. BWheatstone
    3. Cpercentage
    4. D0
    5. E10
    6. Fknown
    7. Gflammable
  5. 5Mass Spectometry
    Function: Sample is drawn in by vacuum to the [blank_start]ionization[blank_end] chamber. Individual gases are [blank_start]separated[blank_end] and analyzed.
    Measures: Gas percentages
    Advantages: [blank_start]Rapid[blank_end] Response time, breath by breath analysis, multiple gas analysis
    Can analyze: [blank_start]He[blank_end], [blank_start]N2[blank_end], [blank_start]O2[blank_end], [blank_start]CO2[blank_end]
    Disadvantages: Expensive, large, high maintenance
    Most Suitable for: analysis of [blank_start]several[blank_end] patient at once rather than individual testing.
    1. Aionization
    2. Bseparated
    3. CRapid
    4. DHe
    5. EN2
    6. FO2
    7. GCO2
    8. Hseveral
  6. 6Nitrogen analyzer

    Also known as: [blank_start]Geissler[blank_end] Tube Ionizer
    Sample is pumped into [blank_start]ionization[blank_end] chamber where light is emitted and monitored by a phototube. Intensity of light is directly [blank_start]proportional[blank_end] to N2%
    Measures gas percentage
    Capable of breath by breath analysis
    Calibration: To zero with [blank_start]100[blank_end]% O2 and a [blank_start]known[blank_end] concentration.
    1. AGeissler
    2. Bionization
    3. Cproportional
    4. D100
    5. Eknown
  7. 7O2 Analyzers
    Galvanic [blank_start]Fuel[blank_end] Cell Analyzer: Measures partial [blank_start]pressure[blank_end] and displays [blank_start]FiO2[blank_end] as %.
    If unable to calibrate you should replace the [blank_start]fuel[blank_end] cell.
    Calibration during exercise testing: Low [blank_start]12[blank_end]-[blank_start]14[blank_end]% and high [blank_start]21[blank_end]%

    Poloragraphic Analyzer
    Similar to galvanic but uses a [blank_start]battery[blank_end]
    Analogous to the [blank_start]Clark[blank_end] electrode
    Calibration is to [blank_start]21[blank_end]% and [blank_start]100[blank_end]%
    1. AFuel
    2. Bpressure
    3. CFiO2
    4. Dfuel
    5. E12
    6. F14
    7. G21
    8. H21
    9. I100
    10. JClark
    11. Kbattery

Información

Descripción
El usuario ha eliminado su información de asignaturas Test sobre Gas Anaylzers, creado por Usuario eliminado el 19/08/2016.
Autor
Usuario eliminado
Idioma
English
Visitas
40
Historial
Creado el 19 ago 2016 · actualizado el 25 ago 2016

Escríbenos

¿Sobre qué es tu mensaje?

¿Qué te parece el nuevo diseño?

¿Te gusta?