¡GoConqr estrena diseño! Cuéntanos qué te parece.

Test

CNIM WRONG/ NEED TO KNOW

Suzanne Picciurro 193 preguntas

Hacer el test

Preguntas del test (193)

  1. 1The Post Central Gyrus is most likely located at?Imagen de la pregunta 1
    1. AD
    2. BA
    3. CB
    4. DC
  2. 2When placing PF you want the active electrode:
    1. ALateral to the PF
    2. BBelow the PF crease
    3. CMedial to the PF
    4. DAbove the PF crease
  3. 3The bin width of your system is 20 uS; then the highest frequency signal that can be resolved is:
    1. A50 KHz
    2. B25 KHz
    3. C20 KHz
    4. D100 KHz
  4. 4Cortel-Dubousset Instrumentation involves which of the following?
    1. AIntervertebral Diskectomy
    2. BSublaminar Wires
    3. CDistraction
    4. DDerotation
  5. 5Stimulating the median nerve at the wrist yields an Erbs Point response at 10ms and an NCV of 60m/S. What is the distance between the cathode and the Erbs point recording electrode?
    1. A166 cm
    2. B60 cm
    3. CCannot be determined with this information
    4. D50 cm
  6. 6Which of the following responses increases linearly with an increase in stimulus intensity?
    1. APop Fossa
    2. BP31
    3. CMN cortical
    4. DPTN cortical
  7. 7Why are SSEP and MEP used simultaneously?
    1. ASpinal cord damage can occur in only one tract causing loss of MEP but not SSEP
    2. BAll of the above
    3. CBecause SSEP monitoring alone is not very sensitive to changes in spinal cord function
    4. DBecause MEPs indicate spinothalamic function
  8. 8For Peroneal Nerve Stimulation, the ground should be placed at?
    1. AFoot
    2. BCalf
    3. CAnkle
    4. DThigh
  9. 9Upon seeing the traces collected at 19:54, the first thing you should do is?Imagen de la pregunta 9
    1. ACheck anesthetic Levels
    2. BReset the amplifier
    3. CInform the surgeon of an abrupt loss of the BAER
    4. DContinue to monitor for return of the response
  10. 10A major advantage of digital filters over analog filters is:
    1. AThey impose no phase effects on the recorded signal
    2. BThey operate faster than analog signals
    3. CThey require digitization of the analog signal
    4. DThey reduce or eliminate frequencies above or below a given cutoff

Información

Descripción
Test sobre CNIM WRONG/ NEED TO KNOW, creado por Suzanne Picciurro el 12/08/2019.
Idioma
English
Visitas
3
Etiquetas
cnim
Valoración
Aún sin valoraciones
Valora este test
Valora este test

Más sobre EEG and Electrophysiology

Escríbenos

¿Sobre qué es tu mensaje?

¿Qué te parece el nuevo diseño?

¿Te gusta?