¡GoConqr estrena diseño! Cuéntanos qué te parece.

Test

Passive Design- Passive solar heating

Raelle Barnard 38 preguntas

Hacer el test

Este test tiene tipos de pregunta que se abren en el reproductor de siempre.

Preguntas del test (38)

  1. 1Fossil fuel resources are not [blank_start]endless[blank_end], so the price of it will rise in the future. [blank_start]Renewable[blank_end] energy [blank_start]technology[blank_end] will be developed further and might get [blank_start]cheaper[blank_end], however they still need an initial [blank_start]investment[blank_end].
    1. Aendless
    2. BRenewable
    3. Ctechnology
    4. Dcheaper
    5. Einvestment
  2. 2Sustainable Design: The [blank_start]tier[blank_end] [blank_start]approach[blank_end]
    [blank_start]Renewable[blank_end] energy
    Mechanical [blank_start]heating[blank_end] and [blank_start]cooling[blank_end]
    [blank_start]passive[blank_end] systems
    [blank_start]basic[blank_end] building design

    Renewable energy- Mechanical heating and cooling
    However the [blank_start]mechanical[blank_end] system won't be [blank_start]small[blank_end] enough to be powered by [blank_start]renewable[blank_end] energy or passive systems won't work. Basic building design must be [blank_start]climate[blank_end] responsive.
    1. Atier
    2. Bapproach
    3. CRenewable
    4. Dheating
    5. Ecooling
    6. Fpassive
    7. Gbasic
    8. Hsmall
    9. Iclimate
    10. Jrenewable
    11. Kmechanical
  3. 3Passive Design
    -Passive design is a key element of [blank_start]sustainable[blank_end] construction
    -Maximise [blank_start]comfort[blank_end] + minimise [blank_start]energy[blank_end] use
    -only use the energy available locally (nothing new: similar to vernacular architecture)
    -uses the [blank_start]natural[blank_end] flow of energy prevailing on site and works with it
    1. to [blank_start]heat[blank_end]
    2. to [blank_start]cool[blank_end]
    3. to ill[blank_start]uminate[blank_end]
    4. to ven[blank_start]tilate[blank_end] a place
    1. Asustainable
    2. Bcomfort
    3. Cenergy
    4. Dnatural
    5. Eheat
    6. Fcool
    7. Guminate
    8. Htilate
  4. 4Passive Design.
    has been [blank_start]adapted[blank_end] by a design which generally uses little [blank_start]energy[blank_end], and is highly energy efficient.
    with this new interpretation of passive design small mechanical "[blank_start]active[blank_end]" [blank_start]appliances[blank_end] can be used to achieve user [blank_start]comfort[blank_end].
    1. Aadapted
    2. Benergy
    3. Cactive
    4. Dcomfort
    5. Eappliances
  5. 5Passive Design
    -low [blank_start]energy[blank_end] and energy [blank_start]efficent[blank_end] buildings means careful considerations of [blank_start]heating[blank_end], [blank_start]cooling[blank_end], [blank_start]lighting[blank_end] and [blank_start]ventilation[blank_end] systems
    -[blank_start]solar[blank_end] [blank_start]control[blank_end] means of heating, cooling and ventilating needs to be [blank_start]available[blank_end] when it would be beneficial but has to be eliminated if detrimental to a comfortable [blank_start]indoor[blank_end] [blank_start]climate[blank_end].
    1. Aenergy
    2. Befficent
    3. Cheating
    4. Dcooling
    5. Elighting
    6. Fventilation
    7. Gcontrol
    8. Hsolar
    9. Iavailable
    10. Jindoor
    11. Kclimate
  6. 6Passive Design
    -uses the following principles to improve on the [blank_start]thermal[blank_end] [blank_start]comfort[blank_end] and [blank_start]energy[blank_end] performance of a building
    1. [blank_start]orientation[blank_end]
    2. [blank_start]glazing/solar control[blank_end]
    3. [blank_start]insulation[blank_end]
    4. [blank_start]ventilation[blank_end]
    5. [blank_start]zoning[blank_end]
    6. [blank_start]thermal mass[blank_end]
    1. Athermal
    2. Bcomfort
    3. Cenergy
    4. Dorientation
    5. Eglazing/solar control
    6. Finsulation
    7. Gventilation
    8. Hzoning
    9. Ithermal mass
  7. 7The building [blank_start]bioclimatic[blank_end] chart
    -used as a tool to decide what [blank_start]systems[blank_end] are valid for the [blank_start]climate[blank_end]
    Procedure
    -plot 2 points
    1. monthly average [blank_start]min[blank_end] temp with the [blank_start]max[blank_end] rh
    2. monthly average max [blank_start]temp[blank_end] with the min [blank_start]rh[blank_end]
    - then link both points for each month
    - each [blank_start]line[blank_end] will represent the hange in temp and rh over and averge [blank_start]day[blank_end]
    - one "pair" of data = 1 point
    - one line = 1 month
    1. Abioclimatic
    2. Bsystems
    3. Cclimate
    4. Dmin
    5. Emax
    6. Ftemp
    7. Grh
    8. Hline
    9. Iday
  8. 8Passive [blank_start]solar[blank_end] heating
    - technique that uses [blank_start]heat[blank_end] of the [blank_start]sun[blank_end] to [blank_start]regulate[blank_end] a buildings [blank_start]temp[blank_end] without using other [blank_start]energy[blank_end] [blank_start]sources[blank_end]
    - successful use of passive design depends upon
    1. the [blank_start]correct[blank_end] understanding of [blank_start]sun's[blank_end] [blank_start]movements[blank_end]
    2. the best use of [blank_start]mterials[blank_end] and their [blank_start]placement[blank_end] in order to capitalise on the solar energy
    1. Asolar
    2. Bheat
    3. Csun
    4. Dregulate
    5. Etemp
    6. Fenergy
    7. Gsources
    8. Hsun's
    9. Icorrect
    10. Jmovements
    11. Kmterials
    12. Lplacement
  9. 9Main objectives of solar [blank_start]heating[blank_end]
    1. to [blank_start]minimise[blank_end] all [blank_start]areas[blank_end] of heat [blank_start]loss[blank_end] from the building
    2. [blank_start]maximise[blank_end] heat [blank_start]gains[blank_end] within each [blank_start]space[blank_end]
    1. Aheating
    2. Bminimise
    3. Closs
    4. Dareas
    5. Emaximise
    6. Fgains
    7. Gspace
  10. 10Passive Solar heating
    - to [blank_start]minimise[blank_end] [blank_start]heat[blank_end] [blank_start]loss[blank_end] by
    1. [blank_start]infiltration[blank_end]
    2. [blank_start]conduction[blank_end]
    1. Aminimise
    2. Bloss
    3. Cinfiltration
    4. Dconduction
    5. Eheat

Información

Descripción
minimise heat loss- infiltration and convection maximise solar gain- direct, indirect and isolated solar gain
Idioma
English
Visitas
19
Valoración
Aún sin valoraciones
Valora este test
Valora este test

Escríbenos

¿Sobre qué es tu mensaje?

¿Qué te parece el nuevo diseño?

¿Te gusta?