Notas
Liquid Static Measurement and Tank Gauging
Conteúdo das notas (1)
Página 1
Liquid Static Measurement and Tank Gauging
Every time the product changes ownership measurement of the
product and custody of the product are transferred to another party.
Quantities typically measured for custody transfer and
monitoring/controlling facilities:
·
Volume flow rate accumulated at transfer points
·
Pressure at custody transfer and pressure
control points (pump stations/peak points)
·
Temperature at custody transfer and temperature
control points ( injection/delivery)
·
Density at the custody transfer and batch
lifting/delivery points
·
Quality at the custody transfer and batch
lifting/delivery points
Measurement Systems are installed for:
·
Custody transfer
·
Inventory control
·
Batch size determination
·
Leak detection and line balancing purposes
Measurement is done statically or dynamically.
Static: involves measuring tank volume and its changes over
time
Dynamic: involves measuring hydrocarbons under flowing
conditions by a meter
Process Control and Internal Product Transfer Measurement:
can use vortex shedding and orifice meters.
Static Measurement:
requires exacting attention to the detail and precision in
the calculation process and the underlying supporting processes.
Supporting processes include:
·
Tank calibration
·
Calibration of temperature and pressure
transmitters
·
Densitometer calibration
·
Tank gauging equipment verification or
calibration
Tank Calibration:
Manual Tank Strapping Method
(MTSM):
·
Tanks must be calibrated after they have been
filled at least one with a liquid of density equal to or greater than that of
the liquid it will hold in the future.
·
Hydrostatic test is applied to all
new tanks
·
In order to determine tank capacities
dimensional measurements and determination of weights are necessary using the
following methods
o
Circumferential measurement: uses steel tape aka
tank strapping
o
Height
o
Deadwood
o
Floating roof – weight of the roof material
o
Tank bottom survey
·
Wall thickness of the circumferential plates and
of the paint used on the tank walls is necessary to be able to achieve the
correct internal volume
Optical Reference Line Method
(ORLM)
·
Uses an optical device but requires manual
strapping of a reference circumferential course.
·
The strapping of the first ring is set 20% below
the top horizontal weld seam and acts as a datum
Optical Triangulation Method (OTM)
·
A laser is used to externally calibrate vertical
cylindrical tanks by measuring angles.
·
No access to the tank roofs is necessary
·
A measured reference is necessary by strapping
at a location near the bottom ring
·
Two stations are present per ring and is
established at 20% of the distance from the upper and lower horizontal weld
seams for each tank ring.
Electro-Optical Distance Ranging Method
(EODRM)
·
Uses internal measurement procedures outline in
API MPMS chapter 2
·
An electro-optical distance-ranging instrument
capable of precision angular measurement and a laser beam emitter are involved.
·
Distances and slope angles are measured at a
predetermined number of target points around the internal circumference of the
tank
·
Placed on the tank floor and stabilized to
prevent movement. It should be located at or near the center of the tank. All
target points are sighted along the horizontal plane at each course location.
Tank
Capacity Table:
They’re
determined from the dimensional measurements obtained through the calibration
procedures.
Recalibration
of tank required establishing revised tank capacity tables
Liquid
Calibration of Tank:
If
the tank shapes are irregular or unknown or inaccessible liquid calibration may
be required this takes place using a positive displacement meter.
Tank
Gauging:
Manual Tank Gauging:
manual
gauge tape must be calibrated and certified to a national standards.
Some
operations don't allow open access to tank contents because of hazardous vapors
or for emission control purposes. In these cases it is desirable to implement
manual closed tank gauging systems.
Servo Tank Gauge:
Automatic
tank gauge (ATG) involves a physical connection of the servo instrumentation to
a level sensor or float or a physical connection to a floating roof.
Servo
tank gauge can provide a product level indication as well as product density,
can be used to determine Net Standard Volume of the tank contents (NSV)
When
using Servo tank gauge on a floating roof tank, a gauging platform is required
in order to mount the gage over the product. (Tank roof for IFR or actual
platform)
Stilling
Well: provides stability and calm to the product surface allowing for more
accurate measurements.
Accurate
temperature information is accomplished by the installation of multiple
resistance temperature detector RTD elements each of a different length in a
prove that traverses the entire height of the tank.
Microprocessors
determine the RTDs and average their temperature.
Radar Tank Gauge:
Very
reliable and suitable for custody transfer purposes in tanks with open
visibility to the liquid.
Non
contact device
Needs
to be installed with instruments of similar accuracy in the measurement of
product temperature and density. Stilling well is recommended for radar level
measurements.
Hybrid Tank Measurement System (HTMS):
Combines
accurate level gauge instrumentation with temperature sensors and pressure
transmitters.
Uses
level-based and mass-based systems it can obtain tank level, temperature, mass
and density.
Components
of Hybrid Tank Measurement System:
·
An automatic tank gauge
·
Tank thermometer system
·
Tank bottom pressure sensor and transmitter
·
A processor that provides an accurate conversion
of pressure to density
These
four components calculate NSV.
Calculation
of Tankage Volumes:
NSV
is the primary unit of measurement for custody transfer and product inventory
control. It is the equivalent volume of a liquid at its base temperature and
pressure conditions. Doesn't include non-merchantable items
To
obtain NSV you must:
Obtain TOV; total observed Volume,
determined by measuring the liquid height of the tank. You reference the liquid
height in the tank to the calculated volume from the tank capacity table.
GSV:
Gross standard volume, the total volume of petroleum liquids and S&W
TCV:
Total Calcualted volume
TOV:
total observed volume
Informações
- Descrição
- Normal-level (N-level) Transmission and Storage (Midterm 2 ) Notas sobre Liquid Static Measurement and Tank Gauging , criado por Yasmina Moussa em 29-11-2015.
- Criado por
- Yasmina Moussa
- Visualizações
- 54
- Tags
- Avaliação