O GoConqr está de visual novo! Conte para nós o que você achou.

Flashcards

Ultrasonic Testing Level I

Rusty Shackleford Inglês 47 flashcards

Ultrasonic Testing Level I

Flashcards do conjunto (47)

  1. 1If the major dimensions of a discontinuity in a 15 cm (6in.) thick aluminum plate lie parallel to the entry surface at a depth of 76 mm (3 in.) it will be best detected by:a straight beam test
  2. 2when setting up a distance amplitude correction curve using 3 flat bottom holes, sometimes the hole closest to the transducer gives less of a response than one or both of the other two, this could be caused by:near field effects,
    inconsistent surface of the calibration block,
    incorrect hole geometry
  3. 3when an ultrasonic beam passes through the interface between two dissimilar materials at an angle, a new angle of sound travel takes place in the second material due to:refraction
    (read this one carefully because they will trick you with the word "rarefaction")
  4. 4Which of the following discontinues located 15 cm (6 in.) from the entry surface would result in the largest CRT indication if all factors except discontinuity surface condition and orientation are the same?a 2mm (0.08 in.) diameter FLATE-SURFACED discontinuity shoes major face is PERPENDICULAR to the direction of sound beam propagation
  5. 5ultrasonic testing of material were the search unit is in direct contact with the material being tested bay be: a. angle beam testing. b. all answers. C. surface wave testing. D. straight beam testing.B. all answers
  6. 6most commercial ultrasonic testing is accomplished using frequencies between: a. 15 and 100 MHz B. 0.2 and 25 MHz C. 1 and 100 kHz D. 1 and 25 kHz0.2 and 25 MHz
  7. 7when performing a surface wave test, indications may result from: a. oil on the surface b. surface discontinuities c. all answers d. dirt on the surfaceall answers
  8. 8an ultrasonic test thing a straight beam contact search unit is being conducted through the thickness of a flat part such as a plate. this test should detect:laminar-type flaws with major dimensions PARALLEL to the rolled surface
  9. 9which component in an ultrasonic immersion system is used to adjust and maintain a known transducer angle? a. search tube b. manipulator c. carriage d. index systemb. manipulator
  10. 10the velocity of sound in a material is dependent upon the: a. frequency of the wave b. material properties c. wavelength d. vibration cycleb. material properties
  11. 11The indication on the cathode ray tube (CRT) with represents the far boundary of the material being tested is called: A. thi initial pause B. the main bang C. the back surface reflection D. hashThe back surface reflection
  12. 12A search unit containing three or more individual transducer elements is often referred to as: a. sandwich transducer b. dual transducer c. a mosaic transducer d. none of the abovec. a mosaic transducer
  13. 13on the area amplitude ultrasonic standard test blocks the flat bottom holes in the blocks are:different in diameter, increasing by 0.4 mm (0.016 in.) increments from the No "1" block to the No. "8" block
  14. 14what is the most common type of data display used for ultrasonic examination of welds? A. B-scan B. C-Scan C. A-scan D. X-Y plotC. A-scan
  15. 15As the grain site increases in a material, its principal effect In ultrasonic testing is on the: a. angle of refraction b. velocity of sound c. attenuation d. acoustic impedancec. attenuation
  16. 16which circuits modify the return signal from the receiving transducer into a form suitable for display on an oscilloscope or other output device? a. receiver-amplifier b. pulser c. sweep d. clocka. receiver-amplifier
  17. 17a separate time base line imposed on the viewing screen of some ultrasonic testing instruments that permits measurement of distances is often referred to as: a. sweep line b. initial pulse c. marker d. time/distance linec. marker
  18. 18Search units constructed with a plastic wedge or standoff between the transducer element and the test piece are commonly used for a. surface wave contact testing b. angle beam contact testing c. dual transducer straight beam contact testing d. all answersd. all answers
  19. 19in immersion testing, verification that the search unit is normal to a flat entry surface is indicated by: a. elimination of water multiples b. maximum amplitude of the initial pulse c. proper wavelength d. maximum reflection from the entry surfaced. maximum reflection from the entry surface
  20. 20in ultrasonic testing, a liquid coupling medium between the crystal surface and the part surface is necessary because:an air interface between the crystal surface and the part surface would almost completely reflect the ultrasonic vibrations
  21. 21penetration of ultrasonic waves in a material is normally the function of test frequency used. which of the following frequencies would provide the greater depth of penetration? a. 1 MHz b. 2.25 MHz C. 10 MHz D. 5MHzA. 1 MHz
    (lower frequencies= greater depth of penetration)
  22. 22Which frequency will produce the shortest wavelength pulse? a. 25 MHz B. 1 MHz C. 5 MHz D. 10 MHza. 25 MHz
    (high frequency = short wavelength)
  23. 23if a discontinuity is located in the fresnel or near field region of a sound beam:in immersion testing, the amplitude of REFLECTED SIGNAL may INCREASE OR DECREASE as water path decreases
  24. 24an ultrasonic testing technique in which the transducer element is not parallel to the test surface is called A. contact testing B. through-transmission testing c. immersion testing d. angle beam testingd. angle beam testing
  25. 25a. C-scan b. A-scan c. D-scan d. B-scanA. C-Scana. C-scan b. A-scan c. D-scan d. B-scan
  26. 26The component in a conventional immersion system that spans the width of the immersion tank is called: a. a bridge b. search tube c. manipulator d. articulatora. a bridge
  27. 27A. surface wave testing b. angle beam testing c. straight beam testing d. immersion testingc. straight beam testingA. surface wave testing b. angle beam testing c. straight beam testing d. immersion testing
  28. 28in immersion testing, the most commonly used coupling is: a. oil b. water c. glycerin d. alcoholb. water
  29. 29if the velocity of a longitudinal mode wave in a given homogenous material is 0.625 cm/ns at 13 mm )0.5 in.) below the surface, what is the velocity at 51 mm (2 in.) below the surface?The same as the velocity at 13mm (0.5 in.)
    (velocity is a constant)
  30. 30reasons for using reference/ calibration standards?They provide a common basis for expressing test results.
    they provide a measure of the test systems performance.
    they provide a method for standardizing the test system.
    (all answers)
  31. 31most ferrous and nonferrous welds may be ultrasonically tested using a frequency range of: a. 1-2.25 MHz b. 25-100 kHz c. 3-6 MHz d. 10-20 MHz e. 200-500 kHza. 1-2.25 mHz
  32. 32the boundary between two different materials which are in contact with each other is called: a. rarefactor b. refractor c. marker d. interfaced. interface
  33. 33in immersion testing, a wetting agent is added to the water to: a. prevent cloudiness b. adjust the viscosity c. help eliminate the formation of air bubblesd. help eliminate the formation of air bubbles
  34. 34When a C-scan recording is used to produce a permanent record of an ultrasonic test, the information displayed is typically the discontinuities: a. location and depth b. depth and size c. depth orientation and size d. location and size (plan view)d. location and size (plan view)
    (any answer that says "depth" is wrong
  35. 35100 000 cycles per second can be written: a. 0.1 kHz b. 100 kHz c. 10 kHz d. 100 MHzb. 100 kHz
  36. 36the primary purpose of reference blocks is to: a. Aid the operator in obtaining max back reflectors b. obtain a common reproducible signal c. obtain the greatest sensitivity possible from an instrumentb. obtain a common reproducible signal
  37. 37—the first back surface reflectionthe first back surface reflection
  38. 38in the transverse or hear wave, the particles: a. oscillate at a right angle to the direction of wave propagation b. oscillate parallel to the direction of wave propagation c. move in a elliptical patterna. oscillate at a right angle to the direction of wave propagation
  39. 39when performing a contact inspection on a curved surface, what piece of equipment can be used to improve coupling: a. a spherically focused transducer b. a shaped shoe c. a cylindrically focused transducer d. a large diameter transducerb. a shaped shoe
  40. 40ultrasound is generally defined as sound t frequency above the threshold of human hearing which is? a. 20,000 Hz b. 2 Hz c. 20,000 MHz d. 2 Mhza. 20,000 Hz
  41. 41the number of cycles per second is the definition of: a. hertz b. wave speed c. none of the answers d. frequencyd. frequency
  42. 42Snell's Law describes the relationship between the sound velocity and: a. the refracted angle b. the reflected angle c. both d. nonec. both
    (refracted and reflected angle)
  43. 43the frequency marked on a transducer indicates: a. the highest frequency produced buy the transducer b. the range of transducers operating frequency c. the center frequency at which the transducer operatesc. the center frequency at which the transducer operates
  44. 44the measure of how a signal from a defect compared to other background reflections is called: a. refraction b. signal to noise ratio c. reflection d. acoustic impedanceb. signal to noise ratio
  45. 45in order to have a reasonable chance at detecting a discontinuity, the reflexive surface of the discontinuity music have a dimension that is at least as long as ________ wavelength a. one-half b. one-quarter c. two d. onea. one-half
  46. 46mode conversion occurs when a sound wave encounters an interface between material of different acoustic impedance and: a. one of the two materials in a liquid b. the incident angle is greater than the first critical angle c. the incident angle is not normal to the interfacec. the incident angle is not normal to the interface
  47. 47when an ultrasound wave passes through an interface between two materials at an oblique angle, and the materials have different indices of reaction, it produces: a. reflected waves b. refracted waves c. bothc. both
    (reflected and refracted waves)