Flashcards
Module 10: Quality
Flashcards do conjunto (95)
- 1Who assesses blood banks in its accreditation program:AABB (American Association of Blood Banks)
- 2Who sets the standards for hospital transfusion services:CSTM (Canadian standards for Transfusion Medicine)
- 3What is the reporting of any error or accident in the manufacturing or processing of blood components that may affect the component in any way.Occurrence management
- 4What is the transport temperature of RBC:1-10oC
- 5What is the transport temperature for platelets:20-24oC
- 6What is the transport temperature for plasma:frozen
- 7What is the storing temperature for RBC:1-6oC
- 8What is the storing temperature for platelets:20-24oC
- 9What is the storing temperature for plasma products:< -18oC
- 10What functions should be checked on serofuges and centrifuges:1. speed
2. timer
3. calibration (capable of settling the cell wells or obtaining a good seperation) - 11When should serofuges and centrifuges should be checked:Every 6 months
- 12When should thermometers should be checked:Yearly against NIST thermometer
- 13What should be checked in a cell washer:1. addition of saline
2. cross contamination
3. centrifugation
4. decanting
5. resuspension
6. addition of AHG
7. speed/timer - 14How long are the temperature record charts kept:5 years
- 15Quality control for anti-A reagent:Pos: A2 or A2B cells
Neg: B cells - 16Quality control for anti-B reagent:Pos: B cells or AB cells
Neg: A cells - 17Quality control for A1 cells:Pos: anti-A
Neg: anti-B - 18Quality control for A2 cells:Pos: anti-A
Neg: anti-B - 19Quality control for B cells:Pos: anti-B
neg: anti-A - 20How is the potency of anti-D tested:with Rh(D) positive cells
- 21How is the specificity of anti-D tested:with Rh(D) negative cells
- 22What to use for a positive antisera control (ex: anti-M):Heterozygous cells (ex: M+N+)
- 23False negative or false positive result: patient's sample omitted from the test:False negative
- 24False negative or false positive result: Incorrect temperatureFalse negative
- 25False negative or false positive result: improper incubation timeFalse negative
- 26False negative or false positive result: improper washingFalse negative
- 27False negative or false positive result: patient's sample is too oldFalse negative
- 28False negative or false positive result: under centrifugationFalse negative
- 29False negative or false positive result: over wagglingFalse negative
- 30False negative or false positive result: not carefully observing during wagglingFalse negative
- 31False negative or false positive result: omitting microscopic readings on negatives when using AHGFalse negative
- 32False negative or false positive result: not using an agglutination mirror to viewFalse negative
- 33False negative or false positive result: heavy cell suspension (antigen excess)False negative
- 34False negative or false positive result: sample collected from IV lineFalse negative
- 35False negative or false positive result: poly-agglutinated RBCFalse positive
- 36False negative or false positive result: wharton's jelly makes cord cells very stickyFalse positive
- 37False negative or false positive result: colloidal silica and multivalent ions that leeched out of glass:False positive
- 38False negative or false positive result: insignificant, complement binding IgMsFalse positive
- 39False negative or false positive result: centrifuging PEGFalse positive
- 40False negative or false positive result: reading PEG microscopicallyFalse positive
- 41False negative or false positive result: over centrifugation:False positive, RBC may be clumped rather than agglutinated
- 42False negative or false positive result: over shaking to remove RBC button:False negative
- 43False negative or false positive result: dirty glassware can neutralize AHG:False negative
- 44False negative or false positive result: dirty glassware may cause RBC to adhere to each otherFalse positive
- 45False negative or false positive result: improper storage of RBC may cause loss of reactivityFalse negative
- 46False negative or false positive result: improper storage of RBC may cause bacteria to growFalse positive
- 47Can the addition of saline be accomplished by a cell washer:Yes
- 48Can centrifugation be accomplished by a cell washer:Yes
- 49Can decanting the saline wash supernatant be accomplished by a cell washer:Yes
- 50Can resuspension of RBC button be accomplished by a cell washer:Yes
- 51Can addition of coombs control cells be accomplished by a cell washer:Yes
- 52True or false: in the quality assurance of reagent RBC, a positive control is used to assess reactivityTrue
- 53True or false: in the quality assurance of reagent RBC, a positive control is used to assess potencyFalse
- 54True or false: in the quality assurance of reagent RBC, a positive control is used to assess specificityFalse
- 55True or false: in the quality assurance of reagent RBC, a positive control is used to assess avidityFalse
- 56True or false: in the quality assurance of reagent RBC, a positive control is used to assess absence of false agglutinationFalse
- 57True or false: a negative control for reagent antiserum assesses reactivityFalse
- 58True or false: a negative control for reagent antiserum assesses potencyFalse
- 59True or false: a negative control for reagent antiserum assesses specificityTrue
- 60True or false: a negative control for reagent antiserum assesses avidityFalse
- 61True or false: a negative control for reagent antiserum assesses colorFalse
- 62True or false: a suitable positive control for antiserum is a cell which is homozygous for the corresponding antigenFalse
- 63True or false: a suitable positive control for antiserum is a cell which is heterozygous for the corresponding antigenTrue
- 64True or false: a suitable positive control for antiserum is a cell which is either homozygous or heterozygous for the corresponding antigenFalse
- 65True or false: a suitable positive control for antiserum is a cell which lacks the corresponding antigenFalse
- 66True or false: a suitable positive control for anti-C is CCFalse
- 67True or false: a suitable positive control for anti-C is CcTrue
- 68True or false: a suitable positive control for anti-C is CC or CcFalse
- 69True or false: a suitable positive control for anti-C is ccFalse
- 70True or false: coombs cells do not agglutinate when added to a negative IAT tube because the incubation time is too shortFalse
- 71True or false: coombs cells do not agglutinate when added to a negative IAT tube because cells are not adequately washedTrue
- 72True or false: coombs cells do not agglutinate when added to a negative IAT tube because AHG is not addedTrue
- 73True or false: coombs cells do not agglutinate when added to a negative IAT tube because AHG is not reactiveTrue
- 74True or false: coombs cells do not agglutinate when added to a negative IAT tube because AHG has been contaminated with serumTrue
- 75True or false: Inadequate washing of the RBC may result in a false positive antiglobulin testFalse
- 76True or false: Absence of complement may result in a false positive antiglobulin testFalse
- 77True or false: Wharton's jelly in a cord specimen may result in a false positive antiglobulin testTrue
- 78True or false: the absence of IgG in a patient's serum may result in a false positive antiglobulin testFalse
- 79True or false: Temperature of blood bank refrigerators must be monitored by a continuous recorderTrue
- 80True or false: Temperature of blood bank refrigerators must be monitored by periodic calibration which mimics conditions that are too warm or too coldTrue
- 81True or false: Temperature of blood bank refrigerators must be monitored by an audible alarmTrue
- 82True or false: Temperature of blood bank refrigerators must be monitored for their abilityFalse
- 83True or false: anti-A antisera should be quality controlled dailyTrue
- 84True or false: anti-D antisera should be quality controlled dailyTrue
- 85True or false: anti-B antisera should be quality controlled dailyTrue
- 86True or false: anti-C antisera should be quality controlled dailyFalse
- 87True or false: Coombs control cells should be checked daily with AHGTrue
- 88True or false: Coombs control cells should be checked daily with sensitized cellsFalse
- 89True or false: Coombs control cells should be checked daily with salineTrue
- 90True or false: Coombs control cells should be checked daily with unsensitized cellFalse
- 91True or false: the potency of broad spectrum AHG is assessed using IgG sensitized cellsTrue
- 92True or false: the potency of broad spectrum AHG is assessed using IgM sensitized cellsFalse
- 93True or false: the potency of broad spectrum AHG is assessed using complement coated cellsTrue
- 94True or false: the potency of broad spectrum AHG is assessed using unsensitized cellsFalse
- 95When cell typing with an antiserum that requires AHG, the patient results are reportable only after the following results are achieved:1. positive control gives at least 1+ reaction
2. coombs cells agglutinate in all appropriate tubes
3. negative control does not agglutinate
4. the patient's DAT or autocontrol is negative
Informações
- Descrição
- 1 Transfusion Medicine FlashCards sobre Module 10: Quality, criado por Angela Haché em 06-06-2016.
- Criado por
- Angela Haché
- Visualizações
- 1
- Avaliação