  1. 1Who assesses blood banks in its accreditation program:AABB (American Association of Blood Banks)
  2. 2Who sets the standards for hospital transfusion services:CSTM (Canadian standards for Transfusion Medicine)
  3. 3What is the reporting of any error or accident in the manufacturing or processing of blood components that may affect the component in any way.Occurrence management
  4. 4What is the transport temperature of RBC:1-10oC
  5. 5What is the transport temperature for platelets:20-24oC
  6. 6What is the transport temperature for plasma:frozen
  7. 7What is the storing temperature for RBC:1-6oC
  8. 8What is the storing temperature for platelets:20-24oC
  9. 9What is the storing temperature for plasma products:< -18oC
  10. 10What functions should be checked on serofuges and centrifuges:1. speed
    2. timer
    3. calibration (capable of settling the cell wells or obtaining a good seperation)
  11. 11When should serofuges and centrifuges should be checked:Every 6 months
  12. 12When should thermometers should be checked:Yearly against NIST thermometer
  13. 13What should be checked in a cell washer:1. addition of saline
    2. cross contamination
    3. centrifugation
    4. decanting
    5. resuspension
    6. addition of AHG
    7. speed/timer
  14. 14How long are the temperature record charts kept:5 years
  15. 15Quality control for anti-A reagent:Pos: A2 or A2B cells
    Neg: B cells
  16. 16Quality control for anti-B reagent:Pos: B cells or AB cells
    Neg: A cells
  17. 17Quality control for A1 cells:Pos: anti-A
    Neg: anti-B
  18. 18Quality control for A2 cells:Pos: anti-A
    Neg: anti-B
  19. 19Quality control for B cells:Pos: anti-B
    neg: anti-A
  20. 20How is the potency of anti-D tested:with Rh(D) positive cells
  21. 21How is the specificity of anti-D tested:with Rh(D) negative cells
  22. 22What to use for a positive antisera control (ex: anti-M):Heterozygous cells (ex: M+N+)
  23. 23False negative or false positive result: patient's sample omitted from the test:False negative
  24. 24False negative or false positive result: Incorrect temperatureFalse negative
  25. 25False negative or false positive result: improper incubation timeFalse negative
  26. 26False negative or false positive result: improper washingFalse negative
  27. 27False negative or false positive result: patient's sample is too oldFalse negative
  28. 28False negative or false positive result: under centrifugationFalse negative
  29. 29False negative or false positive result: over wagglingFalse negative
  30. 30False negative or false positive result: not carefully observing during wagglingFalse negative
  31. 31False negative or false positive result: omitting microscopic readings on negatives when using AHGFalse negative
  32. 32False negative or false positive result: not using an agglutination mirror to viewFalse negative
  33. 33False negative or false positive result: heavy cell suspension (antigen excess)False negative
  34. 34False negative or false positive result: sample collected from IV lineFalse negative
  35. 35False negative or false positive result: poly-agglutinated RBCFalse positive
  36. 36False negative or false positive result: wharton's jelly makes cord cells very stickyFalse positive
  37. 37False negative or false positive result: colloidal silica and multivalent ions that leeched out of glass:False positive
  38. 38False negative or false positive result: insignificant, complement binding IgMsFalse positive
  39. 39False negative or false positive result: centrifuging PEGFalse positive
  40. 40False negative or false positive result: reading PEG microscopicallyFalse positive
  41. 41False negative or false positive result: over centrifugation:False positive, RBC may be clumped rather than agglutinated
  42. 42False negative or false positive result: over shaking to remove RBC button:False negative
  43. 43False negative or false positive result: dirty glassware can neutralize AHG:False negative
  44. 44False negative or false positive result: dirty glassware may cause RBC to adhere to each otherFalse positive
  45. 45False negative or false positive result: improper storage of RBC may cause loss of reactivityFalse negative
  46. 46False negative or false positive result: improper storage of RBC may cause bacteria to growFalse positive
  47. 47Can the addition of saline be accomplished by a cell washer:Yes
  48. 48Can centrifugation be accomplished by a cell washer:Yes
  49. 49Can decanting the saline wash supernatant be accomplished by a cell washer:Yes
  50. 50Can resuspension of RBC button be accomplished by a cell washer:Yes
  51. 51Can addition of coombs control cells be accomplished by a cell washer:Yes
  52. 52True or false: in the quality assurance of reagent RBC, a positive control is used to assess reactivityTrue
  53. 53True or false: in the quality assurance of reagent RBC, a positive control is used to assess potencyFalse
  54. 54True or false: in the quality assurance of reagent RBC, a positive control is used to assess specificityFalse
  55. 55True or false: in the quality assurance of reagent RBC, a positive control is used to assess avidityFalse
  56. 56True or false: in the quality assurance of reagent RBC, a positive control is used to assess absence of false agglutinationFalse
  57. 57True or false: a negative control for reagent antiserum assesses reactivityFalse
  58. 58True or false: a negative control for reagent antiserum assesses potencyFalse
  59. 59True or false: a negative control for reagent antiserum assesses specificityTrue
  60. 60True or false: a negative control for reagent antiserum assesses avidityFalse
  61. 61True or false: a negative control for reagent antiserum assesses colorFalse
  62. 62True or false: a suitable positive control for antiserum is a cell which is homozygous for the corresponding antigenFalse
  63. 63True or false: a suitable positive control for antiserum is a cell which is heterozygous for the corresponding antigenTrue
  64. 64True or false: a suitable positive control for antiserum is a cell which is either homozygous or heterozygous for the corresponding antigenFalse
  65. 65True or false: a suitable positive control for antiserum is a cell which lacks the corresponding antigenFalse
  66. 66True or false: a suitable positive control for anti-C is CCFalse
  67. 67True or false: a suitable positive control for anti-C is CcTrue
  68. 68True or false: a suitable positive control for anti-C is CC or CcFalse
  69. 69True or false: a suitable positive control for anti-C is ccFalse
  70. 70True or false: coombs cells do not agglutinate when added to a negative IAT tube because the incubation time is too shortFalse
  71. 71True or false: coombs cells do not agglutinate when added to a negative IAT tube because cells are not adequately washedTrue
  72. 72True or false: coombs cells do not agglutinate when added to a negative IAT tube because AHG is not addedTrue
  73. 73True or false: coombs cells do not agglutinate when added to a negative IAT tube because AHG is not reactiveTrue
  74. 74True or false: coombs cells do not agglutinate when added to a negative IAT tube because AHG has been contaminated with serumTrue
  75. 75True or false: Inadequate washing of the RBC may result in a false positive antiglobulin testFalse
  76. 76True or false: Absence of complement may result in a false positive antiglobulin testFalse
  77. 77True or false: Wharton's jelly in a cord specimen may result in a false positive antiglobulin testTrue
  78. 78True or false: the absence of IgG in a patient's serum may result in a false positive antiglobulin testFalse
  79. 79True or false: Temperature of blood bank refrigerators must be monitored by a continuous recorderTrue
  80. 80True or false: Temperature of blood bank refrigerators must be monitored by periodic calibration which mimics conditions that are too warm or too coldTrue
  81. 81True or false: Temperature of blood bank refrigerators must be monitored by an audible alarmTrue
  82. 82True or false: Temperature of blood bank refrigerators must be monitored for their abilityFalse
  83. 83True or false: anti-A antisera should be quality controlled dailyTrue
  84. 84True or false: anti-D antisera should be quality controlled dailyTrue
  85. 85True or false: anti-B antisera should be quality controlled dailyTrue
  86. 86True or false: anti-C antisera should be quality controlled dailyFalse
  87. 87True or false: Coombs control cells should be checked daily with AHGTrue
  88. 88True or false: Coombs control cells should be checked daily with sensitized cellsFalse
  89. 89True or false: Coombs control cells should be checked daily with salineTrue
  90. 90True or false: Coombs control cells should be checked daily with unsensitized cellFalse
  91. 91True or false: the potency of broad spectrum AHG is assessed using IgG sensitized cellsTrue
  92. 92True or false: the potency of broad spectrum AHG is assessed using IgM sensitized cellsFalse
  93. 93True or false: the potency of broad spectrum AHG is assessed using complement coated cellsTrue
  94. 94True or false: the potency of broad spectrum AHG is assessed using unsensitized cellsFalse
  95. 95When cell typing with an antiserum that requires AHG, the patient results are reportable only after the following results are achieved:1. positive control gives at least 1+ reaction
    2. coombs cells agglutinate in all appropriate tubes
    3. negative control does not agglutinate
    4. the patient's DAT or autocontrol is negative