O GoConqr está de visual novo! Conte para nós o que você achou.

Fluxograma

Sem título

Raul Guillermo Morales Juarez Inglês

Conteúdo do fluxograma

  1. 1. Gather 3-4 spinach leaves and a hole punch

  2. 2. Using a one-hole punch, cut 20 leaf disks from the spinach leaves

  3. 3. Prepare a sodium bicarbonate and water solution

    Weigh 1.5g of sodium bicarbonate in a large beaker

    Add 300mL of water to the beaker containing the sodium bicarbonate and stir until fully

    dissolved.

    Using a pipette, add approximately 2 drops of liquid dish soap to the solution and stir gently

    (avoid bubbles!)

    Divide this solution evenly into 2 smaller beakers

  4. 4. Find the plastic syringe and remove the plunger.

  5. 5. Place the 20 leaf disks into the body of the syringe.

  6. 6.Reinsert the plunger in the syringe, being careful not to damage the leaf disks.

  7. 7. Insert the syringe into the beaker containing the sodium bicarbonate and water

    solution. Pull the plunger back to draw up the solution. Draw approximately half the

    volume of the syringe can hold (ie draw 15mL if the syringe can hold 30mL). Your

    leaf disks should float.

  8. 8. Hold the syringe tip upward and expel all the air in the body of the syringe by

    depressing the plunger carefully.

  9. 10.

    Gently release the plunger, then remove your index finger. You should see the

    leaf disks sink.

    If some leaf disks do not sink, try tapping the side of the syringe.

    If some leaf disks still do not sink, repeat steps 8-10 once more.

    Do NOT repeat steps 8-10 more than 3 times! It will damage the leaf disks.

    If after repeating, some leaf disks remain floating continue to step 11 and

    record this in the results section.

  10. 14. Observe what happens to the leaf disks. Copy

    the chart to the right in your lab notebook under

    the “results” section and complete it during the

    lab. Stop recording after 15 minutes.

  11. 9. Seal the tip of the syringe using the index finger of your left hand and hold the

    syringe tightly. Pull back on the plunger creating a partial vacuum (this takes

    some force to create the vacuum!) Hold this seal for about 5 seconds.

  12. 15. Using the data that you collect, create a double

    line graph in your lab report

  13. 11.

    Remove the plunger from the syringe and pour the leaf disks and solution evenly into the two smaller

    beakers.

    There should be 10 leaf disks and approximately 150 mL of solution in each beaker

  14. 12. Place one beaker approximately 6-10 inches

    under a light source (or outside in the sunlight) ,

    and place the other beaker in a location that is

    covered or blocked from the light.

  15. 13. Begin timing the experiment as soon as the

    beaker is placed under the light source.

Informações

Descrição
Fluxograma sobre Sem título, criado por Raul Guillermo Morales Juarez em 27-01-2024.
Visualizações
0
Avaliação

Fale Conosco

Sobre o que é sua mensagem?

O que você acha do novo visual?

Você gostou?