- What is it?
- a high energy pulsed alternating current designed to stimulate motor nerves and muscle fibers
- muscle frequency alternating current (MFAC)
- carrier frequency is preset or can be set
- duty cycle varies
- muscle frequency alternating current (MFAC)
- burst frequency - packages of AC current
- ON:Off ratio - Work:rest ratio
- ramp time
- a high energy pulsed alternating current designed to stimulate motor nerves and muscle fibers
- Medium frequency alternating current (MFAC)
- uses medium carrier frequency
- 2500-10000 Hz
- higher frequency meets less skin resistance - will likely go deeper into tissue
- Deep muscle > or equal to 5000 Hz
- duty cycle
- calculated w/ continuous alternating current
- so the stimulation is not uncomfortable - it is an internal time (ON/ON + OFF) = %
- increases comfort allowing maximum contraction and comfort
- so the stimulation is not uncomfortable - it is an internal time (ON/ON + OFF) = %
- calculated w/ continuous alternating current
- Phase duration aka duty cycle
- higher duty cycle is not always better but will deliver more energy
- 100% - a continuous alternating current not available for muscle
- 40-50%: most machines preset here but may allow 10-50%
- uses medium carrier frequency
- Evidence Based Medicine
- burst frequency is set for the type of stimulus you want: Twitch, tetany, or fatgiue
- ON:OFF times for work to rest ratio
- on time is when the current is provided
- off times set for rest
- mimics repetitions and rest
- re-education - 1:1 of 1:2
- atrophy reduction - 1:4 or 1:5
- total duration along with ON:OFF ratio set determines the # of repetitions you will do in the tx
- What is it?
HiVolt for muscle contraction
- interphase interval
- Theratouch 7.7; RichMar and Winner; Intellect and Vectra
- cant change
- phase duration = 50 microseconds
- interpulse interval = 100 microseconds
- cant change
- high voltage monophasic pulsed currents
- variable interphase interval from 10-20 microseconds
Patterned electrical nerve stimulation (PENS)
- Omnistim machines
- form of muscle stimulation that replicates the correct firing patterns of muscle
- precise reproduction of EMG firing patterns of agonist and antagonist muscle pairs
- agonist/antagonist/agonist - "triphasic"
- precisely timed input to the nerves and muscle stretch receptors
- Goal to re-establish proper firing sequence in the spinal and supraspinal central pattern generators
- reboot of spinal reflex system an may have an effect on corticospinal activity
- Goal to re-establish proper firing sequence in the spinal and supraspinal central pattern generators
- Can ehnace correction of foot drop, walking speed, and balance in individuals with hemiparesis
- combining w/ voluntary muscle contractions in untrained and/or injured pts
- PENS trained muscle will "learn" the firing pattern associated with "trained" muscle
- What is changing with the neuromuscular system
- Ca2+ channels - accumulation
- interneuron efficiency
- central control improving
- decreasing chronic inflammation stimuli
- Recent research
- active changes - a single bout of isometric training combined with PENS increased voluntary extension torque
- neuromuscular efficiency: motor unit recruitment, median firing frequency and motor unit synchronization
- decrease of inhibitory signals - interneuron efficiency
- active changes - a single bout of isometric training combined with PENS increased voluntary extension torque
- Omnistim machines