Questão 1
Questão
Conventional gas- and oil-fired boilers are currently used in the vast majority of residential and light commercial hydronic systems in North America.
Questão 2
Questão
The cast-iron sectional boiler is currently one of the most common boilers used in residential and light commercial buildings in North America.
Questão 3
Questão
If a cast-iron boiler is significantly oversized and experiences long off-times between firing cycles, much of the heat stored in the boiler's thermal mass can be carried up the flue by air currents passing through the combustion chamber.
Questão 4
Questão
Many boilers currently used in North America were designed with the intent that flue gases would condense within the boiler.
Questão 5
Questão
Condensing boilers are designed with large heat exchanger surfaces capable of extracting more heat from the exhaust gases compared to the heat exchangers in conventional boilers.
Questão 6
Questão
In full storage ETS systems, all energy used during the subsequent on-peak period is purchased and stored during the peak cycle.
Questão 7
Questão
The term "hydronic heat pump" always refers to a heat pump that delivers heat to a flowing stream of water.
Questão 8
Questão
The heating capacity of the heat pump drops rapidly with increasing source water temperature.
Questão 9
Questão
It is not advisable to maintain water flow through the condenser whenever the heat pump is operating.
Questão 10
Questão
The decision to use a wood-fueled boiler involves a time commitment much more demanding than for conventional heat sources operating on natural gas, propane, fuel oil, or electricity.
Questão 11
Questão
Most cast-iron sectional boilers are limited to use in __________ hydronic systems.
Responda
-
"bare-bones"
-
packaged
-
closed-loop
-
distributed
Questão 12
Questão
The combination of metal and water weight gives cast-iron boilers the ability to absorb a significant amount of heat. Such boilers are said to have a high __________.
Responda
-
life cycle
-
thermal mass
-
efficiency factor
-
size
Questão 13
Questão
One type of boiler design surrounds the combustion chamber with a water-filled heat exchanger. This arrangement is called a __________ boiler.
Responda
-
hydraulic
-
condensation
-
steam
-
wet-base
Questão 14
Questão
Analysis of combustion processes reveals that significant amounts of heat can be recaptured from the exhaust stream if the water vapor it contains can be _________.
Questão 15
Questão
Boilers with low thermal mass tend to have __________ cycle efficiencies due to lesser amounts of heat remaining in the boiler following burner shutdown.
Responda
-
lower
-
unpredictable
-
higher
-
dependable
Questão 16
Questão
A boiler operates at __________ efficiency only when it is being fired continuously under nonvarying conditions.
Responda
-
steady-state
-
measurable
-
DOE-certified
-
manufacturer
Questão 17
Questão
A __________ is a device for converting low-temperature heat into higher temperature heat.
Responda
-
thermal converter
-
radiating unit
-
flue gasket
-
heat pump
Questão 18
Questão
A flow restriction or stoppage in the __________ can lead to rapid formation of ice crystals on the cold heat exchanger surfaces separating the water and refrigerant.
Responda
-
storage tank
-
water source
-
evaporator
-
closed-loop
Questão 19
Questão
In solar anti-freeze based combisystems, the outside heat dump provides a way for the system to shed excess heat. It is activated if the temperature of the thermal storage tank reaches a _________ upper limit.
Responda
-
manufacturer recommended
-
DOE enforced
-
user-set
-
local fire code
Questão 20
Questão
It is vital that the solar collectors and all exposed piping in a drain-back system be pitched a minimum of __________ toward the storage tank to allow complete drainage.
Responda
-
1/4 in./ft.
-
1/2 in./ft.
-
1/8 in./ft.
-
1/16 in./ft.