1Select the items below that are elements of professionalism.
- ACredentials and ability
- BPersonal image and ethos
- CRemain current in your profession
- DCriticizing other colleagues or company
2When beginning a new project, which of the following do you need to know prior to starting work.
- AJob location and work area
- BCode requirements
- CProject schedule
- DClosest resturants
3Communication must be ____________, clear, concise,_____________, truthful, and free from unacceptable language.
- Afast, direct
- Btimely, direct
- Cfast, unbiased
- Dtimely, unbiased
4What is the purpose of a code?
- ATo ensure safety during the installation and use of materials, components, fixtures, systems, premises, and related subjects.
- BTo improve the quality, function, performance, repeat-ability or some other facet of the item being defined.
5One of the purposes of a standard is to ensure a minimal level of acceptable performance whereas codes do not ensure the system functionality.
- ATrue
- BFalse
6Which ANSI/TIA standard cover pathways and spaces?
- A568
- B569
- C607
7This standard covers administration and labeling...
- A569
- B606
- C607
8This standard covers bonding and grounding ( earthing )...
- A568
- B606
- C607
- D570
9What is the minimum number of cables to a work area?
- A1
- B2
- C3
- D4
10What distributes the signal between the TE or TR ( FD ) to the work area?
- ABackbone cable
- BOptical Fiber cable
- CHorizontal cable
- DEquipment cord
11What does the color purple identify in the termination field?
- ADemarcation
- BNetwork
- CCommon equipment
- DMiscellaneous
12What does the color yellow signify at the termination field?
- ADemarcation
- BNetwork
- CCommon Equipment
- DMiscellaneous
13What is the maximum length of a horizontal optical fiber cable?
- A10 m , 32.8 ft
- B90 m, 295 ft
- C100 m, 328 ft
14Undercarpet cable is recommended for voice applications.
- ATrue
- BFalse
15What is the purpose of a consolidation point?
- AAllows horizontal cabling to be extended into work area pathways
- BServes as a transition point to undercarpet cable
- CActs as a cross-connection location for backbone and horizontal cables
16The administration class for a single building with multiple telecommunication spaces
- AClass 1
- BClass 2
- CClass 3
- DClass 4
17Administration class for multiple sites with multiple buildings
- AClass 1
- BClass 2
- CClass 3
- DClass 4
18Electronic Identifiers prevent potential intruders from identifying the location of key components
- ATrue
- BFalse
19Which topology would you recommend for a structured cabling backbone distribution system in buildings or in campus environment?
- ARing
- BStar
- CHierarchical star
20PON technology is capable of delivering voice, data and video services to the end user via a single strand of multimode optical fiber cabling.
- ATrue
- BFalse
21Which device manages one or more resources shared by workstation users and administrators on a network?
- AServer
- BRouter
- CNetwork software
22Which network component makes it possible to segment a network into multiple broadcast domains?
- Aserver
- Brouter
- Cswitch
23Which network application typically uses the most bandwidth?
- AUnified Communications
- BVideo communications
- CVideoconferencing
24The purpose of the telecommunications ER in a data center is to house the external network interface and the SP/AP demarcation.
- ATrue
- BFalse
25What room or space in a data center contains the MC (CD) for the computer room cabling?
- AEDA
- BHDA
- CMDA
- DZDA
26Cabling inside a computer room in a data center differs from that inside an ER by the density of the cable.
- ATrue
- BFalse
27OSHA stands for the Occupational Safety and Health Association
- ATrue
- BFalse
28What hazards do hard hats protect installer from?
- Afalling and flying objects
- Belectrical shock
- Cblow to the head
- Dsunburn
29How much vertical space does one rack unit occupy?
- A1 in.
- B1.5 in.
- C1.75 in.
- D2 in.
30How much clearance should there be between the bottom of the access floor and the top of the cable tray?
- A2 in.
- B4 in.
- C6 in.
31What is the maximum number of 90 degree bends allowed between two pull boxes that are ( 30 ft ) apart?
- A2
- B3
- CNone
32A hand bender can be used for conduits up to ________________ diameter.
- A3/4 in
- B1 in.
- C1 1/4 in.
- D1 1/2 in.
33Open top cable supports should be installed to provide a minimum of _____________ clearance above ceilings
- A1 in.
- B2 in.
- C3 in.
- D6 in.
34What is the minimum recommended AWG for backbone bonding conductor?
- A#8
- B#6
- C3/0
35What is the recommended maximum value for the bonding resistance between the two points on bonded surfaces?
- A0.1 ohms
- B.01 ohms
- C1.0 ohms
36In a multistory building it is recommended that placement for BBC be on the top floor and every third floor.
- ATrue
- BFalse
37Secondary protectors are installed to handle________________
- Aheat coils
- Bsneak currents
- Clow-voltage data signals
38What are the steps for troubleshooting a cabling system.
- AVerify the problem
- BIsolate the source
- CRepair and retest