Unit 206: Domestic hot water systems practice test

Description

Unit 206: Domestic hot water systems
james crowley
Quiz by james crowley, updated more than 1 year ago
james crowley
Created by james crowley about 6 years ago
7876
1

Resource summary

Question 1

Question
Which one of the following pieces of information will be provided by the installation plan?
Answer
  • a. The dwelling position on the estate
  • b. The expected completion date
  • c. The order in which work should take place
  • d. The position of the hot water pipes and valves in a dwelling.

Question 2

Question
The water supply (water fittings) regulations 1999 lay down:
Answer
  • a. The regulations covering all internal and external hot and cold water systems for dwellings
  • b. The guidance for good practice when installing hot and cold pipework in a dwelling
  • c. The regulations that cover hot water systems only
  • d. The guidance for internal hot and cold water systems only within a dwelling.

Question 3

Question
Which one of the following hot water components should be fixed using flexible connections?
Answer
  • a. Indirect hot water cylinder
  • b. Shower mixer valve
  • c. Booster pump for a shower
  • d. External bib tap.

Question 4

Question
A rigid pipework hot water system has a working pressure of 4bar. At what pressure should the pipework be tested for soundness?
Answer
  • a. 1bar for 60 minutes
  • b. 1½ times the working pressure for 15 minutes
  • c. 6bar for one hour
  • d. 4bar for 30mins then 6bar for 15 minutes.

Question 5

Question
To prevent electrolytic corrosion taking place in a system, where can the magnesium rod be placed?
Answer
  • a. The cold water storage cistern
  • b. The hot water cylinder
  • c. The circulator
  • d. The open vent.

Question 6

Question
Guidance on the installation procedures for domestic hot water systems can be found in:
Answer
  • a. Domestic Water Act 2007
  • b. Specification of work
  • c. BS6700
  • d. Local Authority Regulations.

Question 7

Question
In a customer’s property, the CWSC supplies both the hot and cold water systems. The minimum size of this cistern is:
Answer
  • a. Equal to 48 hours’ worth of water
  • b. 230 litres
  • c. 100 litres
  • d. Twice the size of the domestic hot water cylinder.

Question 8

Question
Which of the following appliances is most likely to offer the customer low pressure at a hot water outlet?
Answer
  • a. Combination boiler
  • b. Direct cylinder
  • c. Combination unit
  • d. Indirect cylinder.

Question 9

Question
What is this item?
Answer
  • a. Pressure/temperature relief valve
  • b. Double check valve
  • c. Stop valve
  • d. Blending valve.

Question 10

Question
If hard water is allowed to be heated above 65oC, what could be the consequence in the system?
Answer
  • a. Legionella could grow
  • b. The blending valve would fail to work
  • c. The pressure relief valve would open
  • d. The efficiency could be affected by limescale.

Question 11

Question
What is used at a basin outlet to prevent contamination of the water system?
Answer
  • a. AUK2 air gap
  • b. AUK3 air gap
  • c. AG air gap
  • d. AUK4 air gap.

Question 12

Question
A customer has intermittent flow of hot water from their bath tap – what is the most likely cause of the problem?
Answer
  • a. Too little head pressure
  • b. Too much head pressure
  • c. Air lock
  • d. Faulty float operated valve.

Question 13

Question
What is the primary function of the open vent on a domestic hot water system?
Answer
  • a. Safety relief pipe
  • b. Take up a hydraulic shunt
  • c. Allow hot water to be distributed at a controlled pressure
  • d. To balance the feed from the CWSC.

Question 14

Question
To overcome a dead leg for a hot water draw-off point, what course of action could be taken?
Answer
  • a. Install secondary circulation
  • b. Install a more powerful circulator
  • c. Increase the size of the hot water cylinder
  • d. Increase the temperature on the cylinder thermostat.

Question 15

Question
To prevent the risk of legionella forming in a dead leg it should be:
Answer
  • a. No longer than 2.5 metres, as stated in BS6700
  • b. Disinfected annually under a PPM program
  • c. As short as possible
  • d. Always heated to above 50oc

Question 16

Question
What type of shower is this?
Answer
  • a. Instantaneous electric shower
  • b. Thermostatic bar mixer type
  • c. Gravity fed shower
  • d. Bath mixer shower.

Question 17

Question
Identify one advantage of a stored hot water system in a domestic property.
Answer
  • a. There is a continual supply of hot water
  • b. It is cheaper and easier to install
  • c. It does not require a secondary source of heat
  • d. It is suitable for low water pressure areas.

Question 18

Question
18. Which one of the following heat sources is regarded as a renewable source of energy?
Answer
  • a. Coal in a solid fuel boiler
  • b. Gas in a condensing boiler
  • c. Solar panels on the roof of a property
  • d. Electricity supplying an immersion heater.

Question 19

Question
19. Where would state the maximum flow rate and temperature for a particular pumped shower that has been installed?
Answer
  • a. BS6700
  • b. The Water Regulations
  • c. The manufacturer’s instructions
  • d. Building Regulations part G.

Question 20

Question
20. Under Building Regulations part G, what is a new or replacement immersion heater required to have?
Answer
  • a. Temperature relief valve
  • b. Non-resetting overheat thermostat
  • c. Restricted thermostat to a maximum temperature of 60oC
  • d. Protective coating to avoid electrolytic corrosion.

Question 21

Question
Which of the following cylinder types is a direct cylinder?
Answer
  • A
  • B
  • C

Question 22

Question
22. The connection for a secondary circulation system return should be made at what point in the hot water cylinder?
Answer
  • a. Bottom third of the cylinder
  • b. Top third of the cylinder
  • c. Middle point of the cylinder
  • d. Just prior to the open vent connection.

Question 23

Question
23. If a system is prone to limescale build ups, this shows:
Answer
  • a. The property is in a soft water area and the temperatures are set too high
  • b. The property is in a hard water area and the temperatures are set too high
  • c. The property has a gravity hot water system that requires upgrading
  • d. The water pressure in the system is too high and requires reducing.

Question 24

Question
24. If a flow switch on a pumped shower does not work, what would be the result?
Answer
  • a. The water temperature will remain too high
  • b. The water temperature will remain too low
  • c. The pump will not be activated by the electrics
  • d. The pump will have restrictive water flow.

Question 25

Question
25. Under the Water Regulations, what can category 2 water be described as?
Answer
  • a. Wholesome water
  • b. Water representing a slight risk to health
  • c. Wholesome water with its aesthetic qualities impaired
  • d. Water representing a severe risk to health.
Show full summary Hide full summary

Similar

Unit 201: Health and safety in building services engineering
james crowley
Unit 202: Electrical principles and processes for building
james crowley
Common Plumbing Principles practice test
james crowley
Unit 205: Cold water systems - practice test
james crowley
Structure of the construction industry
james crowley
Unit 108 Above Ground Drainage
james crowley
Unit 103 - Environmental and Sustainability Measures in Domestic Dwellings
james crowley
Fundemental working practices - unit 102 - practice test
james crowley
PLUMBING PROCESSES
gaby khalil
Sewer Line Replacement
Colby Grooms
Trenchless Sewer Repair Company
John Roberts