Help shape GoConqr. What should we add next?

Quiz

Risk assessment definitions

Magnus Parmann 11 questions

Take the quiz

This quiz has question types that open in the usual player.

Questions in this quiz (11)

  1. 1Definition – Hazard

    ISO 17776: [blank_start]Potential[blank_end] source of [blank_start]harm[blank_end].

    IEC 60300: Source of [blank_start]potential[blank_end] [blank_start]harm[blank_end] or a situation with a [blank_start]potential[blank_end] for
    [blank_start]harm[blank_end].
    1. APotential
    2. Bharm
    3. Cpotential
    4. Dharm
    5. Epotential
    6. Fharm
  2. 2Definition – (Hazardous) Event

    ISO 31000: [blank_start]Occurrence[blank_end] or [blank_start]change[blank_end] of a particular set of [blank_start]circumstance[blank_end]s.

    ISO 17776: Incident which [blank_start]occur[blank_end]s when a [blank_start]hazard[blank_end] is [blank_start]realized[blank_end].

    IEC 60300: Event which can [blank_start]cause[blank_end] [blank_start]harm[blank_end].

    Marvin Rausand: An event or condition that is [blank_start]required[blank_end] for a [blank_start]hazard[blank_end] to give rise to an [blank_start]accident[blank_end].
    1. AOccurrence
    2. Bchange
    3. Chazard
    4. Drealized
    5. Ecause
    6. Fharm
    7. Grequired
    8. Hhazard
    9. Iaccident
    10. Jcircumstance
    11. Koccur
  3. 3Definition – Failure

    DNV-RP-G101: The point at which a [blank_start]component[blank_end] ceases to [blank_start]fulfil[blank_end] its
    [blank_start]function[blank_end] and the [blank_start]limit[blank_end]s placed on it.

    NORSOK Z-008: Termination of the [blank_start]ability[blank_end] of an item to [blank_start]perform[blank_end] a
    required [blank_start]function[blank_end] (see EN 13306).
    1. Acomponent
    2. Bfulfil
    3. Cfunction
    4. Dability
    5. Eperform
    6. Ffunction
    7. Glimit
  4. 4Definition – Failure Cause

    NORSOK Z-008: Circumstances during [blank_start]design[blank_end], [blank_start]manufacture[blank_end] or [blank_start]use[blank_end] which have led to a failure (see ISO 14224).
    1. Adesign
    2. Bmanufacture
    3. Cuse
  5. 5Definition – Failure Mechanism

    NORSOK Z-008: [blank_start]Physical[blank_end], [blank_start]chemical[blank_end] or other processes which lead or have led to [blank_start]failure[blank_end] (see EN 13306).

    DNV-RP-G101: The means by which a [blank_start]component[blank_end] fails due to the progression of [blank_start]damage[blank_end] beyond the set [blank_start]limit[blank_end]s imposed by the operator (such as a risk acceptance limit) or by physical [blank_start]limit[blank_end]s such as a breach of the component wall.
    1. APhysical
    2. Bchemical
    3. Cfailure
    4. Dcomponent
    5. Edamage
    6. Flimit
    7. Glimit
  6. 6Q: What is the definition of a failure mode?

    A: NORSOK Z-008: [blank_start]Effect[blank_end] by which a failure is [blank_start]observed[blank_end] on the [blank_start]failed[blank_end] item

    DNV-RP-G101: The [blank_start]method[blank_end] by which failure [blank_start]occur[blank_end]s.
    1. Amethod
    2. BEffect
    3. Cobserved
    4. Dfailed
    5. Eoccur
  7. 7Q: Definition of failure rate.

    A: NORSOK Z-008: [blank_start]Number[blank_end] of failures of an [blank_start]item[blank_end] in a given [blank_start]time[blank_end] [blank_start]interval[blank_end] divided by the [blank_start]time[blank_end] [blank_start]interval[blank_end].
    1. ANumber
    2. Bitem
    3. Ctime
    4. Dinterval
    5. Etime
    6. Finterval
  8. 8Hazard: [blank_start]HC is a piping / pipeline[blank_end]
    (Hazardous) Event: Flow rate drop, [blank_start]release of HC[blank_end], fire & explosion (accident)
    Failure: [blank_start]Inability to carry HC[blank_end] (due to blockage or leakage)
    Fault: [blank_start]Blocked or leaking piping[blank_end] - (state)
    Failure cause: [blank_start]Aging[blank_end]
    Failure mechanism: Wax deposition, [blank_start]corrosion, erosion, fatigue, cracking,[blank_end] fracture
    Failure mode: [blank_start]Low flow rate, loss of containment[blank_end]
    Failure rate: [blank_start]Number of leakages per year[blank_end]
    1. Arelease of HC
    2. BInability to carry HC
    3. CBlocked or leaking piping
    4. DAging
    5. Ecorrosion, erosion, fatigue, cracking,
    6. FLow flow rate, loss of containment
    7. GNumber of leakages per year
    8. HHC in a piping / pipeline
  9. 9Definition – Failure Impact

    NORSOK Z-008: Impact of a failure on an [blank_start]equipment[blank_end]'s [blank_start]function[blank_end](s) or on the [blank_start]plant[blank_end] (see ISO 14224).
    1. Aequipment
    2. Bfunction
    3. Cplant
  10. 10Definition – Probability of Failure (PoF)

    ISO 31000:2009: Chance of [blank_start]something[blank_end] [blank_start]happening[blank_end].

    DNV-RP-G101: The probability that failure of a [blank_start]component[blank_end] will occur within a [blank_start]defined[blank_end] time period.

    ABS: Frequency is the [blank_start]expected[blank_end] number of [blank_start]occurrence[blank_end]s of an event expressed as events per unit time.
    1. Asomething
    2. Bhappening
    3. Ccomponent
    4. Ddefined
    5. Eexpected
    6. Foccurrence

Information

Description
Will be pretty hard for anyone not in this class.
Language
English
Views
23
Tags
operations and maintenance
Rating
No ratings yet
Rate this quiz
Rate this quiz

Feedback

What is it about?

What should we add next?