Quiz
Electro-pneumatics Test Prep 1
This quiz has question types that open in the usual player.
Questions in this quiz (43)
1What is an advantage of an electro-pnuematic system?
- AThere are more complex exchange of information between several controllers
- BHigher reliability
- CIt suitable for ALL environments
- DIt requires ONE supply unit
2In an electro-pneumatic system, both the Pneumatic Part and Electrical Part are shown in ONE circuit diagram
- ATrue
- BFalse
3In a JIC Diagram,
- power supply is drawn as two [blank_start]vertical lines[blank_end]
- the signal flow is [blank_start]left to right[blank_end]
- it is read [blank_start]top to bottom[blank_end]- Avertical lines
- Bleft to right
- Ctop to bottom
4What are the three main components of an electro-pneumatic system?
- APower Supply
- BRelay
- CLoad
- DSwitch Element
5A direct circuit means the system uses a relay
- ATrue
- BFalse
6A load consumes power meaning it requires a POSITIVE input and NEGATIVE output
- ATrue
- BFalse
7A switch is load
- ATrue
- BFalse
8What is the function of a solenoid?
- AControl Open/Close Valves
- BControl Relays
- CControl Contactors
- DAll are correct
9Fill in the blanks with monostable or bistable:
A push button is [blank_start]monostable[blank_end] and a control switch is [blank_start]bistable[blank_end]- Amonostable
- Bbistable
10Normally Open switch or contacts are numbered
- A3
4 - B1
2 - C1
2
4 - D5
6
- A3
11A Change Over Switch or Contact is numbered as
- A3
4 - B1
3
4 - C1
2
4 - D1
2
- A3
12which is NOT a sensor
- ALimit Switch
- BControl Switch
- CReed Switch
- DOptical Switch
13A Proximity Switch is actuated by a machine part where as
a Limit Switch requires no external contact- ATrue
- BFalse
14Which proximity sensors are electrically actuated
- AOptical
- BInductive
- CReed
- DCapacitive
15Reed switches are actuated when a magnetic field is present
- ATrue
- BFalse
16Check all the type of optical sensors
- ADiffuse reflective sensor
- BOne Light way Barrier
- CRefraction optical sensor
- DReflective light barrier
17Which are NOT true about Relays
- AThe contacts are usually Normally Closed
- BIt is a load
- CHigh voltage is applied to control another circuit
- DThe armature in the relay is attracted to solenoid coil when there is a magnetic field present
- EIt generates a controlled signal
18On a Time Delay, 1 means ON and 0 means OFF
- ATrue
- BFalse
19A Pull in Time Delay Relay means the first event occurs while the contact of the relay is delayed for a bit then it's activated.
- ATrue
- BFalse
20Drop Out Time Delay Relay means the first event AND the contact of the relay are activated at the same time. However, once the first event is off, the contact of the relay is still ON
- ATrue
- BFalse
21The Pole is the [blank_start]input[blank_end] terminal and the Throw is the [blank_start]output[blank_end] terminal
- Ainput
- Boutput
22The number of Poles = The number of SEPARATE circuits
- ATrue
- BFalse
23The number of Throws = The number of input connections
- ATrue
- BFalse
24A 3/2 Bistable soleniod Valve has
3 Ports
2 Positions
One Solenoid
One Spring- ATrue
- BFalse
25In a DIN circuit, a Contact is drawn the same as a Switch
- ATrue
- BFalse
26In a JIC or DIN circuit with a load and switch, the load is drawn FIRST (near +24v) then the switch is drawn next.
- ATrue
- BFalse
27In an OR operation
1 + 1 =- A2
- B1
- C0
28In an NAND operation,
1 * 0 =- A0
- B1
29In a NOR operation,
1 + 1 =- A1
- B0
- C2
301* 0 =
- A0
- B1
31A * A (bar) =1
- ATrue
- BFalse
32A*1 = A
- ATrue
- BFalse
33A+1=1
- ATrue
- BFalse
34De Morgans Law
Bar all over (A+B) = Bar all over (A*B)- ATrue
- BFalse
35which are true about a Dominant ON circuit
- AIf the ON and OFF switch are pressed at the same time, the circuit is still energized
- BIf the ON button is pressed then released, the relay remains energized
- CIf the ON button is pressed then released, the relay is NOT energized
- DOnce the ON button is pressed then released, the OFF button is meant to stop the relay from being energized
36In a Dominant OFF circuit which are true
- Aif the ON and OFF switch are pressed at the same time, the circuit is not energized
- BIf the ON button is pressed then released, the relay is energized
- Cif the ON and OFF switch are pressed at the same time, the circuit is still energized
371+0+1+0+0+1=
- A1
- B0
- C3
38AB = BA
- ATrue
- BFalse
39A*B*C does NOT equal B*A*C
- ATrue
- BFalse
40A (B+C) = AB + AC
- ATrue
- BFalse
41Number each switch or contact

- A3
- B4
- C1
- D2
- E2
- F4
- G1
- H3
- I4
42In a DIN Diagram,
- the power supply is drawn as two [blank_start]horizontal lines[blank_end]
- signal flow is from [blank_start]top to bottom[blank_end]
- it is read from [blank_start]left to right[blank_end]- Ahorizontal lines
- Btop to bottom
- Cleft to right
43Fill in the blanks with either a number, pole/s, throw/s
- SPST has 1 [blank_start]Pole[blank_end] and [blank_start]1[blank_end] Throw
- DPST has [blank_start]2[blank_end] Poles and 1 [blank_start]Throw[blank_end]
- SPDT has [blank_start]1[blank_end] Pole and [blank_start]2[blank_end] Throws
- DPDT has [blank_start]2[blank_end] Poles and [blank_start]2[blank_end] Throws- APole
- B1
- C2
- DThrow
- E1
- F2
- G2
- H2
Information
- Description
- Quiz on Electro-pneumatics Test Prep 1, created by Ashley Mensah on 13/10/2018.
- Author
- Ashley Mensah
- Language
- English
- Views
- 24
- Rating
- No ratings yet Rate this quiz