Question 1
Question
To change electrical energy to mechanical energy is the purpose of a
Answer
-
Generator
-
Converter
-
Inverter
-
Motor
Question 2
Question
Electrical contact between the stationary and rotating parts of a motor is the function of the
Answer
-
Field windings
-
Commutator
-
Bearings
-
Brushes
Question 3
Question
Torque is defined as
Question 4
Question
In a series-wound direct current (DC) motor, speed is dependent on the
Answer
-
Load
-
Torque
-
Armature
-
Field winding
Question 5
Question
The relationship between slip and torque can best be described as more
Answer
-
Torque causing more slip
-
Slip causing more torque
-
Torque causing less slip
-
Slip causing less torque
Question 6
Question
The three-phase induction motor does not require
Answer
-
Slip
-
A rotor
-
A stator
-
A starting device
Question 7
Question
To reverse the direction of rotation of a three-phase inductive motor, you must reverse
Answer
-
All three phases
-
Any two power leads
-
A and B phases only
-
B and C phases only
Question 8
Question
The stator windings of a synchronous motor are spaced
Answer
-
20 degrees apart
-
30 degrees apart
-
90 degrees apart
-
120 degrees apart
Question 9
Question
The rotation speed of a synchronous motor is controlled by the
Answer
-
Load
-
Torque
-
Input frequency
-
Armature current
Question 10
Question
During an inspection of a direct current (DC) motor, check the brushes for
Answer
-
Pitting
-
Seating
-
Coloration
-
Brittleness
Question 11
Question
When you check the concentricity of a commutator or slip rings, look for
Answer
-
Wear
-
Pitting
-
Roundness
-
Overheating
Question 12
Question
When using a troubleshooting chart, what are you not likely to find?
Answer
-
Analysis
-
Remedies
-
Symptoms
-
Probable causes
Question 13
Question
Most troubleshooting on a motor can be done using a
Answer
-
Megger
-
Growler
-
Multimeter
-
Clamp-on ammeter
Question 14
Question
Perform an operational check of the unit
Answer
-
At the last minute
-
With the defective part removed
-
Before final reassembly of the enclosure
-
As soon as you replace the defective part
Question 15
Question
The component most likely to be damaged by poorly filtered fuel is the
Answer
-
Combustion chamber
-
Transfer pump
-
Fuel lines
-
Injectors
Question 16
Question
The type of injector that is operated by a rocker arm is
Answer
-
Spray
-
Pintle
-
Pressure
-
Mechanical
Question 17
Question
Aside from idle speed, the limiting speed governor through the use of flyweights and spring tension controls
Answer
-
Load speed
-
Minimum speed
-
Maximum speed
-
Intermediate speed
Question 18
Question
A lubricant performs which function when it deposits particles of dirt in the oil sump?
Answer
-
Cooling
-
Sealing
-
Cleaning
-
Reducing friction
Question 19
Question
What component holds a large amount of coolant in close contact with a large volume of air?
Answer
-
Radiator cap
-
Thermostat
-
Water pump
-
Radiator
Question 20
Question
Which liquid cooling system component circulates the coolant?
Answer
-
Vacuum valve
-
Water pump
-
Cooling fan
-
Radiator
Question 21
Question
One of the impellers within a blower on a diesel engine is normally driven
Answer
-
By the engine electrical system through a DC motor
-
By the engine exhaust gases flowing across the turbine wheel
-
From the engine crankshaft through a system of gears or a silent chain
-
Through a solid shaft connected between the blower and the transmission
Question 22
Question
What must be accomplished to supercharge a diesel engine?
Answer
-
Change the overlap and timing so that the intake and exhaust valves are not open at the same time.
-
Change the overlap and timing so that the intake and exhaust valves are open at the same time.
-
Advance exhaust valve opening time
-
Retard intake valve opening time
Question 23
Question
The filtration step protects the diesel engine fuel system from
Question 24
Question
The best step in preventing abnormal amounts of carbon, moisture, and sludge buildup in a diesel engine, is to
Answer
-
Avoid operating the engine for extended periods at no-load
-
Operate the unit at idle speed for long periods of time
-
Drain moisture from fuel system periodically
-
Perform a preoperational check
Question 25
Question
When performing a compression test, measuring pounds per square inch (psi), the maximum allowable deviation between cylinders is
Answer
-
25 psi
-
50 psi
-
75 psi
-
100 psi
Question 26
Question
If the drive shaft for the oil pump assembly in a gas turbine engine becomes sheared, what other component is rendered inoperative?
Question 27
Question
In the gas turbine engine, cooling air for the transformer rectifier is provided by the
Question 28
Question
During gas turbine engine operation, the air is accelerated by the
Answer
-
Diffusers
-
Exducers
-
Impellers
-
Deswirl ring
Question 29
Question
During operation of a turbine engine, fuel and air are mixed and ignited in the
Answer
-
Fuel atomizer
-
Combustor can
-
Mixer assembly
-
Plenum chamber
Question 30
Question
In the operation of a turbine engine, energy is extracted from the burning gases by the
Question 31
Question
The boost pump on the gas turbine engine provides fuel to the
Answer
-
Fuel atomizer
-
Main fuel pump
-
Combustion chamber
-
Fuel air mixture valve
Question 32
Question
Lubrication system pressure in the turbine engine is regulated through a
Answer
-
Flow check valve
-
Filter bypass valve
-
Pressure relief valve
-
Temperature regulator
Question 33
Question
Gas turbine compressor (GTC) operation with insufficient oil pressure is prevented by the
Answer
-
Oil pressure solenoid
-
Oil pressure switch
-
Oil drain switch
-
Ignition coil
Question 34
Question
During turbine engine operation, oil loss into the airflow system is prevented by the
Answer
-
Air-oil seals
-
Oil tank baffles
-
Exhaust vent line
-
Pressure relief valve
Question 35
Question
If the gas turbine compressor (GTC) load control butterfly valve opens too slowly or too quickly, what is the most probable cause of the malfunction?
Answer
-
Excessive exhaust gas temperature
-
Maladjusted rate adjustment screw
-
Ruptured actuator diaphragm
-
Defective relief valve
Question 36
Question
In the turbine engine, rupture of the rate diaphragm is prevented by the
Question 37
Question
Prior to operating any aerospace ground equipment (AGE), you should perform
Question 38
Question
During a preoperational inspection of a gas turbine engine, you check the intake and exhaust for
Answer
-
Leakage
-
Excess heat
-
Hairline cracks
-
Foreign objects
Question 39
Question
Normal acceleration characteristics of the gas turbine compressor (GTC) include
Answer
-
Sudden rumbling noises after 35 percent
-
A decrease in vibration after 35 percent
-
Smooth and quiet acceleration
-
Burping
Question 40
Question
Before you load and after you unload the gas turbine compressor (GTC), allow the engine to operate unloaded to
Question 41
Question
When you operate a unit to determine the validity of an entry on the maintenance record form, what step in effective troubleshooting are you performing?
Answer
-
Analysis
-
Isolation
-
Recognition
-
Verification
Question 42
Question
While troubleshooting the gas turbine compressor (GTC), if you discover there is no oil pressure and the oil filter is dirty, changing the oil filter will not correct the problem because the
Answer
-
Filter bypass valve is stuck open
-
Oil pressure relief valve is stuck open
-
Externally mounted solenoid is stuck closed
-
Scavenge pump is not providing sufficient suction
Question 43
Question
If no oil pressure is available from the main oil pump assembly on the gas turbine compressor (GTC), you should replace the
Question 44
Question
Which causes gray or white smoke to pour from the exhaust stack on the gas turbine compressor (GTC)?
Answer
-
Excessive engine revolutions per minute (rpm)
-
Excessive engine exhaust temperature
-
Oil that enters the airflow system
-
Fuel mixing with the airflow
Question 45
Question
In the gas turbine compressor (GTC), if large amounts of oil are forced through the air-oil seals, the most probable cause is a defective
Answer
-
Main oil pump
-
Scavenge pump
-
Oil tank vent line
-
Oil drain solenoid
Question 46
Question
Which could cause the butterfly valve to oscillate (continually open and close)?
Question 47
Question
Which three things are necessary to produce an electromotive force (EMF) mechanically?
Answer
-
EMF, relative motion, and magnetic field
-
Magnet, lines of force, and relative motion
-
Magnetic field, a conductor, and relative motion
-
Counter-electromotive force (CEMF), a conductor, and magnetic field
Question 48
Question
To increase the output of a generator, you must increase the
Answer
-
Load
-
Resistance of the conductor
-
Strength of the magnetic field
-
Counter-electromotive force (CEMF)
Question 49
Question
What result is achieved by replacing the single rotating conductor of a simple direct current (DC) generator with many coils of wire wound on the same shaft?
Answer
-
Increased output and almost constant alternating current (AC)
-
Increased output and almost constant DC
-
Decreased current and constant AC
-
Decreased current and constant DC
Question 50
Question
The rotor of an alternating current (AC) generator consists of the slip rings and
Answer
-
Armature
-
Starter coil
-
Stator windings
-
Voltage regulator
Question 51
Question
Control of the output voltage of an alternating current (AC) generator is accomplished by varying the
Question 52
Question
In an alternating current (AC) generator, the output frequency is often more critical than the output
Answer
-
Load
-
Phase
-
Current
-
Voltage
Question 53
Question
In a three-phase alternating current (AC) generator, direct current (DC) is applied to the field windings through the brushes and
Answer
-
Diodes
-
Rectifier
-
Slip rings
-
Commutator
Question 54
Question
Three different loads can be supported at the same time by a
Question 55
Question
The self-excited alternating current (AC) generator provides its own field current from a built-in
Question 56
Question
When a load is applied to a self-excited alternating current (AC) generator, exciter field resistance will
Answer
-
Decrease current flow
-
Remain the same
-
Increase
-
Decrease
Question 57
Question
The weak points of the self-excited alternating current (AC) generator are the
Answer
-
Commutator, brushes, and slip rings
-
Commutator, rotor, and slip rings
-
Brushes, commutator, and rotor
-
Brushes, slip rings, and rotor
Question 58
Question
In the brushless alternating current (AC) generator, what provides necessary excitation current?
Question 59
Question
What type of loads can be applied to a generator under test by the A/M24T–8 electrical test set?
Answer
-
Inductive and resistive
-
Reactive and resistive
-
Inductive only
-
Resistive only
Question 60
Question
The A/M24T–8 electrical test set is capable of testing
Answer
-
Aerospace ground equipment (AGE) generator sets only
-
Alternating current (AC) power supplies only
-
Direct current (DC) power supplies only
-
AC and DC power supplies
Question 61
Question
What circuit on the A/M24T–8 load bank is used to check the performance of three-phase alternators?
Answer
-
Special checks
-
Impedance load
-
Aircraft servicing
-
Jet engine servicing
Question 62
Question
What occurs when the load selection switches on the A/M24T–8 load bank are closed?
Question 63
Question
Before connecting a generator set to the load bank, you should
Answer
-
Make sure input power cables are energized
-
Make sure all on-off switches are in the OFF position
-
Close the direct current (DC) section cooling fan doors
-
Place circuit breaker three-phase shock load to ON position
Question 64
Question
When using a load bank to test a generator, follow the procedures outlined in the
Answer
-
Generator technical order (TO) and career development course (CDC)
-
Load bank TO, generator TO, and CDC
-
Generator TO and load bank TO
-
Load bank TO and CDC
Question 65
Question
When using an A/M24T–8 electrical test set, when should the frequency and voltage selector switch be positioned to match input power?
Answer
-
While applying power to the test set
-
Before applying power to the test set
-
After the ABC indicator is illuminated
-
After the 28 volts direct current (VDC) control signal indicator illuminates
Question 66
Question
What maximum alternating current (AC) resistive load can the portable load bank apply to a generator?
Answer
-
65 kilowatts
-
70 kilowatts
-
75 kilowatts
-
80 kilowatts
Question 67
Question
When performing a phase-one periodic inspection (PE), you are going to do a
Answer
-
Detailed annual inspection
-
Relatively quick equipment condition check
-
Special inspection accomplishing the lubrication requirements only
-
Streamline inspection to ensure a unit is operational and serviceable
Question 68
Question
The resistive elements on the A/M24T–8 test set are best cleaned by
Answer
-
Blowing off with 5 pounds per square inch (psi) uncontaminated air
-
Blowing off with 15 psi uncontaminated air
-
Scrubbing with soap and water
-
Steam cleaning
Question 69
Question
On an A/M24T–8 electrical test set, what would prevent the fan motors from operating?
Question 70
Question
The governor of the A/M32A–60A generator set is controlled directly by the
Answer
-
Engine speed
-
Trim control motor
-
Static frequency sensor
-
Manual trim adjustment
Question 71
Question
What is used as a reference for controlling A/M32A–60A engine speed?
Question 72
Question
If the oil pressure switch opens during operation of A/M32A–60A, during which period does it stop operation?
Answer
-
From 0 to 35 percent
-
From 35 to 95 percent
-
From 95 to 100 percent
-
Anytime during operation
Question 73
Question
On the A/M32A–60A, which chambers of the load control valve work together to ensure the butterfly valve opens smoothly?
Answer
-
1 and 2
-
2 and 3
-
1 and 3
-
2 and 4
Question 74
Question
Power for starting the A/M32A–60A is provided by
Answer
-
Batteries
-
Generator
-
Start Switch
-
Master Switch
Question 75
Question
In the event of an overspeed condition, what component of the A/M32A–60A generator electrical system stops the engine?
Question 76
Question
The A/M32A–60A generator set cannot be loaded either electrically or pneumatically until after the
Answer
-
35 percent switch has closed
-
95 percent switch has closed
-
110 percent switch has opened
-
BLEED AIR ON switch is closed
Question 77
Question
The component of the A/M32A–60A that opens and closes the fuel transfer line is the fuel
Answer
-
Level switch, S20
-
Solenoid valve, L1
-
Level control relay, K26
-
Level solenoid valve, L4
Question 78
Question
After the A/M32A–60A generator set has shut itself down due to low fuel, the fuel level relay, K4, must be reset by
Answer
-
Turning the start switch OFF, then ON
-
Turning the master switch OFF, then ON
-
De-energizing the low-level lockout relay
-
De-energizing the low-level warning switch
Question 79
Question
What does the alternating current (AC) voltage regulator of the A/M32A–60A use to determine the amount of adjustment the generator output needs?
Answer
-
AC ammeter
-
AC voltmeter
-
Generator output current
-
Generator output voltage
Question 80
Question
When is 28 volts direct current (VDC) applied to E pin of the alternating current (AC) cable?
Question 81
Question
On the A/M32A–60A generator, what stops battery charging when the batteries are fully charged and prevents discharge when the unit is shut down?
Question 82
Question
On the A/M32A–60A, when the direct current (DC) contactor is in the closed position, the DC ammeter indicates
Question 83
Question
How often are service inspections required?
Question 84
Question
After the A/M32A–60A generator set has reached 95 percent of governed speed, the operator should
Answer
-
Reset the alternating current (AC) system
-
Connect the power cables
-
Adjust the governed speed
-
Connect the bleed air duct
Question 85
Question
When troubleshooting, the actual location of a terminal connection on the unit can best be found by using
Question 86
Question
To find out where a wire is connected, you should consult the
Question 87
Question
What component of the A/M32A–86D energizes to send power to the fuel gauge during operation?
Question 88
Question
What is the purpose of the protective circuits of the A/M32A–86D?
Answer
-
Protects the generator electrical system against damage resulting from an overload, overvoltage, under voltage, and over/under frequency
-
Protects the aircraft electrical system against damage resulting from an overload, overvoltage, under voltage, and over/under frequency
-
Senses fault conditions, stopping the generator
-
Senses fault conditions, stopping the engine
Question 89
Question
How long can you operate the starter on the A/M32A–86D before letting it cool?
Answer
-
60 seconds
-
30 seconds
-
20 seconds
-
10 seconds
Question 90
Question
When troubleshooting any electrical system, you can locate a starting point by first finding the
Question 91
Question
What position must the alarm switch on the EPU–6/E frequency converter be placed prior to operation?
Question 92
Question
What indicator on the EPU–6/E frequency converter indicates an under voltage condition?
Answer
-
Overvoltage
-
Out-of-phase
-
Undervoltage
-
Fault
Question 93
Question
What component on the EPU–6/E frequency converter controls the timing and firing of the silicon controlled rectifier (SCR)?
Question 94
Question
Before using the EPU–6/E frequency converter, you must inspect the
Answer
-
Air inlets for blockage
-
Wiring for secure mounting
-
Maintenance panels for corrosion
-
Interior air vents for secure mounting
Question 95
Question
What problem is indicated by a flashing red over/under voltage indicator light on the EPU– 6/E frequency converter?
Question 96
Question
What printed circuit (PC) card controls the cold-starting aid on the B809A generator set?
Answer
-
Direct current (DC)
-
Annunciator
-
Regulator
-
Engine
Question 97
Question
What signal powers the regulator card output pulse sent to the exciter field of the B809A generator?
Question 98
Question
What condition is sensed by the direct current (DC) card on the B809A generator set?
Answer
-
Over temperature
-
Under frequency
-
Over frequency
-
Low fuel
Question 99
Question
During high-voltage operation of the B809A generator set, what action occurs to prevent the direct current (DC) contactors from closing?
Question 100
Question
If you have a loss of residual magnetism in the exciter field poles, what should you do
Answer
-
Connect TB4–11 to 14 VDC power source
-
Check the Field Transformer
-
Field flash the generator
-
Check the fault display