1Match the following characteristics to the appropriate EDM measurement technique.
1) This technique is capable of measuring longer distances.
Answer: [blank_start]Pulsed Laser Method[blank_end]
2) In reflectorless mode, this technique is only capable of measuring to about 500 links.
Answer: [blank_start]Phase Comparison Method[blank_end]
3) In readings under more difficult observing conditions, such as poor light or poor reflectivity, this technique will work better.
Answer: [blank_start]Pulsed Laser Method[blank_end]
4) This technique has a smaller divergence of the radiation signal.
Answer: [blank_start]Phase Comparison Method[blank_end]
5) This technique is slightly more accurate in distance measurement to a prism.
Answer: [blank_start]Phase Comparison Method[blank_end]- APhase Comparison Method
- BPulsed Laser Method
- CPhase Comparison Method
- DPulsed Laser Method
- EPhase Comparison Method
- FPulsed Laser Method
- GPhase Comparison Method
- HPulsed Laser Method
- IPhase Comparison Method
- JPulsed Laser Method
2You take a measurement across a river using a total station and a subtense bar (you inadvertantly left your prisms at the office, but had a subtense bar with you, go figure!). The subtense bar is exactly 2m wide and you measure an internal angle between each end of the bar of 2° 55' 00". How far away is the subtense bar from the instrument? Show you answers to 2dp and do not show any units.
Answer: [blank_start]39.28[blank_end]- A39.28
3Several reductions are made to an EDM distance. Put these in the correct order:
1 = [blank_start]Instrumental correction[blank_end]
2 = [blank_start]Atmospheric correction[blank_end]
3 = [blank_start]Slope correction[blank_end]
4 = [blank_start]Sea Level correction[blank_end]- AAtmospheric correction
- BSlope correction
- CInstrumental correction
- DSea Level correction
- EAtmospheric correction
- FSlope correction
- GInstrumental correction
- HSea Level correction
- IAtmospheric correction
- JSlope correction
- KInstrumental correction
- LSea Level correction
- MAtmospheric correction
- NSlope correction
- OInstrumental correction
- PSea Level correction
4To fully understand EDM distance corrections you must understand the relationship between the three basic constants - the additive constant (AC), prism constant (PC) and instrument constant (IC). Using these three abbreviations (PC, IC, AC) chose the correct relationship below:
- AIC = PC - AC
- BIC = AC + PC
- CAC = IC + PC
- DAC = IC - PC
- EPC = IC - AC
5Calculate the sea level correction for the line K to L:
Horizontal distance KL = 2,215.235
RL of K = 573.78
RL of L = 716.06
Show answer in metres to 3dp without units and show the sign (±) as necessary (ie show -0.220 for negative 220mm and +0.220 for positive 220mm).
Answer: [blank_start]-0.224[blank_end]- A-0.224
6You measure an EDM line between two survey marks with the following instrument readings and settings:
raw slope distance - 1,075.384 m zenith angle - 94° 10' 00"
ppm setting in instrument - 0 ppm additive constanct (AC) setting in instrument - 0mm
note that the measured line was taken at sea level
The ppm setting should have been + 11 ppm and the AC setting should have been +5 mm. What is the final reduced distance for this measured line? Show your answer to 3 dp and do not show any units.
Answer: [blank_start]1,072.558[blank_end]- A1072.558
7Use the nomograph below to calculate the instrument ppm correction given the temp and pressure for your instrument - a Topcon GTS 3B. Note that the correction can be either positive or negative. Do not show a + for a positive ppm, only 5 and show a negative number in the following format: -5.
Pressure: 696 mmHg
Temperature: 14 ° C
Show you answer to 0 dp and do not show the ppm units.
Answer: [blank_start]23[blank_end]
- A23
8Which of the following corrections for a steel band can be either positive or negative?
- ASag
- BStandardisation
- CSlope
- DTemperature
- ETension
9Match up the following characteristics with the 2 types of EDM modulated waves.
This wave has a longer wavelength.
Answer: [blank_start]Measuring Wave[blank_end]
This wave has a higher frequency.
Answer: [blank_start]Carrier Wave[blank_end]
This wave is more unreliable for long range propagation.
Answer: [blank_start]Measuring Wave[blank_end]
This wave has a dependable phase resolution.
Answer: [blank_start]Measuring Wave[blank_end]
This wave uses infrared em radiation.
Answer: [blank_start]Carrier Wave[blank_end]- AMeasuring Wave
- BCarrier Wave
- CMeasuring Wave
- DCarrier Wave
- EMeasuring Wave
- FCarrier Wave
- GMeasuring Wave
- HCarrier Wave
- IMeasuring Wave
- JCarrier Wave
10An EDM instrument has an accuracy measurement capability of ± (5 plus 5). What is the variance of an EDM measurement at a distance of 663m? Provide your answer in mm to 1dp and do not show any units (ie for 0.0681m - show 68.1).
Answer: [blank_start]8.3[blank_end]- A8.3
11When a phase comparison EDM sends a signal out it goes through a certain order of instrument components. Put them in the correct order below:
Detector optics and phase comparator: [blank_start]5[blank_end]
Reciever and interference filter: [blank_start]4[blank_end]
Beam transmitter: [blank_start]2[blank_end]
Prism receives beam and reflects back: [blank_start]3[blank_end]
Distance display: [blank_start]7[blank_end]
Carrier source/Frequency generator: [blank_start]1[blank_end]
Resolve ambiguity in phases: [blank_start]6[blank_end]- A1
- B2
- C3
- D4
- E5
- F6
- G7
- H1
- I2
- J3
- K4
- L5
- M6
- N7
- O1
- P2
- Q3
- R4
- S5
- T6
- U7
- V1
- W2
- X3
- Y4
- Z5
- AA6
- AB7
- AC1
- AD2
- AE3
- AF4
- AG5
- AH6
- AI7
- AJ1
- AK2
- AL3
- AM4
- AN5
- AO6
- AP7
- AQ1
- AR2
- AS3
- AT4
- AU5
- AV6
- AW7
12Calculate the IC from the following data and 3-peg test results:
Distance 1 - 2 = 43.129
Distance 2 - 3 = 45.511
Distance 1 - 3 = 88.634
AC setting in instrument = 0.000
PC = -0.030
Show answer in metres to 3 dp. Do not show any sign nor units.
Answer: [blank_start]0.024[blank_end]- A0.024
13Choose the best line below to complete this sentence: If an EDM instrument has a specification of (3 + 2) this means:
- AThe instrument has an uncertainty of 03" in an angle and 2mm in a distance.
- BThe standard error of a measurement is ± (3mm plus 2 mm per km).
- CThe instrument has an uncertainty of 3mm in a distance and 02" in an angle.
- DThe additive constant is 3mm and the atmospheric correction is 2ppm
- EThe standard error of a measurement is ±5ppm.
14You measure an EDM line between two survey marks with the following instrument readings and settings:
raw slope distance - 1,103.28 m zenith angle - 85° 39' 00"
ppm setting in instrument - 0 ppm additive constanct (AC) setting in instrument - 0mm
note that the measured line was taken at sea level
The ppm setting should have been a negative -11 ppm and the AC setting should have been +13 mm. What is the final reduced distance for this measured line? Show your answer to 3 dp and do not show any units.
Answer: [blank_start]1100.103[blank_end]- A1100.103
15You are out doing a large rural survey with long EDM distance measurement lines. A weather front passes through the area and the air pressure lowers dramatically and affects your EDM distance measurements. What type of error would this condition introduce?
- ABlunder
- BSystematic Error
- CRandom Error
- DGross Error
Information
- Description
- Quiz on W5 Distance - Quiz, created by MJhendo on 29/09/2015.
- Author
- MJhendo
- Language
- English
- Views
- 1
- Rating
- No ratings yet Rate this quiz