Master Plumber - Private Sewage Disposal Systems

Description

Quiz on Master Plumber - Private Sewage Disposal Systems, created by Josef Lorenz Del on 13/07/2016.
Josef Lorenz Del
Quiz by Josef Lorenz Del, updated more than 1 year ago
Josef Lorenz Del
Created by Josef Lorenz Del almost 8 years ago
408
2

Resource summary

Question 1

Question
The type of system shall be determined on the basis of ______.
Answer
  • Location
  • Soil porosity
  • Ground water level
  • All of the above

Question 2

Question
The capacity of any one septic tank and its drainage system shall be limited by _____.
Answer
  • Location
  • Soil porosity
  • Soil structure classification
  • Ground water level

Question 3

Question
Septic tanks shall have _____.
Answer
  • A maximum of two compartments
  • Atleast three compartments
  • A minimum of two compartments
  • Atleast one compartment

Question 4

Question
The inlet compartment of any septic tank shall be _____.
Answer
  • Not less than two-thirds (2/3) of the total capacity of the tank, nor less than 2cu.m.
  • Less than two-thirds (1/3) of the total capacity of the tank, nor less than 1cu.m.
  • Less than two-thirds (2/3) of the total capacity of the tank, nor less than 2cu.m.
  • Not less than two-thirds (1/3) of the total capacity of the tank, nor less than 1cu.m.

Question 5

Question
Minimum dimensions of septic tank
Answer
  • Atleast 1.2m in width and 1.5m in length
  • Atleast 0.6m in width and 1.2m in length
  • Atleast 0.9m in width and 1.5m in length
  • Atleast 1.2m in width and 1.8m in length

Question 6

Question
Liquid depth shall be _____.
Answer
  • Not less than 0.9m nor more than 1.8m
  • Not less than 0.6m nor more than 1.8m
  • Not less than 0.6m nor more than 1.5m
  • Not less than 0.9m nor more than 1.5m

Question 7

Question
The secondary compartment of any septic tank shall have a _____.
Answer
  • A maximum capacity of two-thirds (2/3) of the total capacity of such tank and a minimum capacity of 2cu.m.
  • A minimum capacity of one-third (1/3) of the total capacity of such tank and a maximum capacity of 1cu.m.
  • A minimum capacity of two-thirds (2/3) of the total capacity of such tank and a maximum capacity of 2cu.m
  • A maximum capacity of one-third (1/3) of the total capacity of such tank and a minimum capacity of 1cu.m.

Question 8

Question
In septic tanks having over 6cu.m. capacity, the secondary compartment may _____.
Answer
  • May not be less than 0.9m in length
  • May not be less than 1.2m in length
  • May not be less than 1.5m in length
  • May not be less than 1.8m in length

Question 9

Question
Access to each septic tank shall be provided by already two (2) manholes _____ in minimum dimension or by an equivalent removable cover slab.
Answer
  • 406mm or 16in
  • 457mm or 18in
  • 508mm or 20in
  • 559mm or 22in

Question 10

Question
Wherever a first compartment exceeds _____ in length, an additional manhole shall be provided over the baffle wall.
Answer
  • 3.1m or 10ft
  • 3.7m or 12ft
  • 4.3m or 14ft
  • 4.9m or 16ft

Question 11

Question
The inlet and outlet pipe or baffle wall shall extend ______ the water surface.
Answer
  • 4in above and atleast 12in below
  • 3in above and atleast 10in below
  • 5in above and atleast 14in below
  • 6in above and atleast 16in below

Question 12

Question
The invert of the inlet pipe small be at a level _____ above the invert of the outlet pipe.
Answer
  • Not less than 2in
  • Not less than 4in
  • Not more than 2in
  • Not more than 4in

Question 13

Question
The side walls shall extend atleast _____ above the liquid depth.
Answer
  • 228.6mm or 9in
  • 177.8mm or 7in
  • 254mm or 10in
  • 203.2mm or 8in

Question 14

Question
The cover of the septic tank shall be atleast _____ above the back vent opening.
Answer
  • 50.8mm or 2in
  • 25.4mm or 1in
  • 76.2mm or 3in
  • 101.6mm or 4in

Question 15

Question
All septic tank covers shall be capable of supporting an earth load of nor less than _____ when the maximum coverage does not exceed _____.
Answer
  • 14.4kPa ; 9m
  • 20.7kPa ; 12m
  • 6.9kPa ; 6m
  • 27.6kPa ; 15m

Question 16

Question
All concrete septic tanks shall be protected from corrosion by coating with an approved bituminous coating or by other acceptable means. The coating shall extend to atleast _____ below the water line and shall cover all the internal area above that point.
Answer
  • 101.6mm or 4in
  • 76.2mm or 3in
  • 127mm or 5in
  • 152.4mm or 6in

Question 17

Question
The minimum wall thickness of any steel tank shall be _____ and each such tank shall be protected from corrosion, both externally and internally, by an approved bituminous coating or by other acceptable means.
Answer
  • No. 12 U.S. gauge (.109) (2.8mm)
  • No. 11 U.S. gauge (.125) (3.2mm)
  • No. 13 U.S. gauge (.094) (2.4mm)
  • No. 14 U.S. gauge (.073) (2.0mm)

Question 18

Question
Clean stone, gravel, slag or similar filter material varying in size from _____ shall be placed in the trench to the depth and grade of required constructing disposal fields.
Answer
  • 3/4in to 2 1/2in
  • 1in to 2 1/2in
  • 1/2in to 3in
  • 3/4in to 3in
Show full summary Hide full summary

Similar

Unit 201: Health and safety in building services engineering
james crowley
Unit 202: Electrical principles and processes for building
james crowley
Common Plumbing Principles practice test
james crowley
Unit 205: Cold water systems - practice test
james crowley
Unit 206: Domestic hot water systems practice test
james crowley
Structure of the construction industry
james crowley
Unit 108 Above Ground Drainage
james crowley
Unit 103 - Environmental and Sustainability Measures in Domestic Dwellings
james crowley
Fundemental working practices - unit 102 - practice test
james crowley
PLUMBING PROCESSES
gaby khalil
Sewer Line Replacement
Colby Grooms