  1. 2 - Radiation Detection

  2. Gas detectors; Ionisation detector

    • Gas detectors; Ionisation detector
    • Incoming particles leave ionisation track
    • voltage across 2 plates; electrons to anode, positive ions to cathode
    • small current generated is proportional to the rate of energy loss in gas
  3. Single particle detection

    • Single particle detection
  4. Proportional counter

    • Proportional counter
    • Similar to gas but the anode is a thin wire
    • For typical values additional ionisation occurs resulting in electron ionising everything it hits
    • almost all ionisation occurs near wire; pulse shape independent of where energy was dumped
    • fast collection time (10ms) and large amplification possible
    • output pulse is proportional to input energy over broad region of initial voltage
  5. Geiger counter

    • Geiger counter
    • similar to proportional counter but operates at higher voltage
    • De-excitation releases uv photons which ionise other atoms, extending the region of ionisation along wire.
    • produces large discharge which eventually stops with buildup of positive charge around the wire
    • +ve ions drift to cathode where high prob of electron being released, retriggering the counter.
    • counter this with a quench gas (eg methane, ethane) which exchanges charge with +ve ions and disassociates harmlessly
  6. general features of gas detectors

    • rugged
    • cheap
    • gas is low density so inefficient for gamma and fast neutrons
    • efficient for charged
    • efficient for thermal neutrons if 3-He or isotopic enriched 10-BF3 used as fill gas
    • coat inner surface with 235-U ; thermal neutron fissions the 235-U, fission product recoil into gas
    • fast neutrons use a moderator polythene ~10cm diameter surrounds and reduces neutron to thermal energy (bonner sphere)
    • Geiger counters have low max count rate ~2000 cps and have finite lifetime due to quench gas used
  7. Scintillator detectors

    • Scintillator detectors
    • Radiation deposits energy in scintillator (usually gamma or xray) creating excitation region
    • The de-excitation releases many photons; 1 Mev gamma ¬ 5*10^4 photons, E= 20ev. Reflection shield helps capture light on photo cathode
    • pulse of current at anode is proportional to # of photons produced which is proportional to energy of incoming radiation (gamma or xray)
    • resoultion deltaE/E ~ 7%
  8. scintillators continued

    • Organic: transparent to its own light due to band gaps.
    • There is a rapid production of flurorescent light
    • Inorganic: Pure crystals have filled valence band ( large band gap - insulator). Not transparent to its own radiation so impurity atoms ( activators) are added. Tl and NaI to provide intermediate states in band gap. Crystals are transparent to light from activator states
  9. Properties of scintillators

    • Inorganic: for gamma rays need high density of -e, ie high atomic number and high material density.
    • NaI- sodium iodide
    • BGO- Bismuth germanate
    • LaBr3- Lanthanum bromide, good resolution
    • Not great resolution (NaI ~6-10%), better for LaBr3
    • 1st interaction for 1Mev gamma will be elastic, if leaves detector is compton spectrum edge
    • can also backscatter
    • or be fully absorbed - full energy photopeak
    • Properties of scintillators
  10. Properties of scintillators

    • Organic: good for B-rays and fast neutrons but too low Z and density for gamma rays ( due to much lower probability interaction -comp scattering)
    • chance of detecting the scattered photon in same crystal or liquid is also low . few events in full E peak
    • Good points for scintillators:
    • high gain, large signal output
    • cheap
    • Bad points:
    • fragile
    • cracks in fast temp changes
    • gain drifts; temp and magnetic affects PMT
  11. Semi conductor detectors

    • accurate - used in research
    • is a single crystal - Si or Ge or CdZnTe
    • voltage applied between electrodes ( p type and n-type)
    • like a solid ( not gas ) ionisation chamber. Radiation creates electron hole pairs which are collected by the contacts. charge collected is proportional to E of radiation
    • small E gap - cooled to liquid N2 ( 77K ) to minimise thermal excitations
    • good resolution - deltaE/E ~ 1/ (N) ^ 1/2
  12. Intrinsic detector

    • very pure crystal with thin p and n type crystals at either end
    • Si- Low Z
    • good for charged particles and x rays
    • DealtaE ~ 20kev for 5Mev alpha
    • finite lifetime due to damage from heavy ions
    • need cooling: but cooling improves resolution
    • Ge - high Z
    • used for gamma rays
    • DealtaE ~ 2 kev at 1.33Mev
    • liquid N2 required for cooling
    • high purity, large volume crystal - expensive
    • 'CZT' - CdZnTe
    • used for gamma and xray
    • good a room temp
    • worse resolution than Ge currently
    • Intrinsic detector
  13. Pn junction detector

    • p type ( acceptor) and n type (donor) are in contact.
    • Electrons from n type diffuse into p type until E field produced stops flow
    • small depletion region is created ( no free charge available)
    • this region is the detector, can increase it by applying an additional reverse bias.
    • If radiation is deposited in the depleted region, free charge is created which is immediately swept away to the contacts by the E field.
    • charge pulse that is measured is proportional to the gamma ( or whatever radiation) Energy
    • can also see extra peaks in NaI detector due to e-e+ annihilation: E + 511 kev if one gamma escapes + 2*511 kev if both are detected
    • Pn junction detector
  14. Folie 14