When carrying out a continuity test would you expect:
b. No reading at all
a. A very high reading
c. A variable reading
d. A very low reading.
A fault in an electric circuit can be caused by:
d. Limited load.
b. Heavy load
c. Over load
a. Low load
Test probes on a multimeter must have a maximum exposed tip of:
a. 1mm
b. 2mm
c. 3mm
d. 4mm.
When working on a system that has had a section of pipework removed, which of the following should be used?
b. Permanent earth continuity bonding
a. Permanent polarity bonding
c. Temporary polarity bonding
d. Temporary earth continuity bonding.
A radiator fitted near to a shower in a bathroom could require:
b. Main bonding
d. Additional bonding.
c. Minor bonding
a. Supplementary bonding
Where is an MCB fitted?
d. Electric shower.
b. Outside socket
c. Extension lead
a. Consumer unit
The design, installation and testing of electrical systems is covered by:
b. BS1212
a. BS6700
c. BS7671
d. BS7176.
The neutral conductor in fixed-cable installations is identified by the insulation being coloured:
c. Blue
a. Red
d. Brown
b. Green/yellow
The relationship between current, resistance and voltage is stated in:
a. Boyle’s law
c. Charge’s law
b. Ohm’s law
d. BS7671.
The type of electricity derived from a battery is:
b. Alternating current
a. Alternating wattage
c. Direct wattage
d. Direct current.
Calculate the fuse rating for a 690w, 230v AC central heating pump.
c. 3 amp
a. 13 amp
d. 1 amp.
b. 5 amp
What is this?
b. Digital manometer
a. Insulation resistance tester
d. Approved voltage tester.
c. Residual current device tester
A domestic consumer unit should be installed:
d. Immediately after the supplier’s meter.
a. Only where there is three phase supply
b. Immediately before the supplier’s sealed fuse unit
c. On each ring circuit
c. Single pole rocker plate pull switch
a. Illuminated fused spur
b. Double pole pull cord switch
d. Wiring centre pull cord.
Which one of the following appliances should have its own separate connection to the consumer unit?
b. Bathroom light
d. Gas boiler.
c. Free-standing fan heater
a. Immersion heater
A boiler, with a rating of 690watt, 230v, 50Hz has been fitted with a 13 amp fuse. Would you:
d. Warn customer not to touch it.
a. Leave it as it is
b. Change it for a 3 amp fuse
c. Fit a 16 amp MCB to protect it
What is this component?
c. 2 gang counter sunk box
d. 2 gang surface mounted box.
b. 1 gang counter sunk box
a. 1 gang surface mounted box
Which one of the following could be interrupted by a disconnection of 400v three-phase supply?
c. Industrial process
b. Domestic lighting
a. Heating of domestic hot water via immersion
d. Domestic ring main.
The normal voltage for a domestic property is:
b. 240v single phase DC
d. 110v single phase AC.
a. 415v three phase AC
c. 230v single phase AC
The flow of electricity through both the live and neutral conductor can be turned off by using:
c. MCB
a. Double pole switch
b. Single pole switch
d. Ring circuit.