  1. 1PROBLEM:
    Classic sludge bulking is occurring in the final clarifier of a conventional activated sludge plant. Indicators include: solids pouring over the weirs, excessive floc observed at the surface, and a homogenous (uniform) sludge blanket appearing throughout the clarifier. Sludge in settling test settles slowly leaving a cloudy supernatant with stragglers. What is the MOST probable cause?
    1. AOver-oxidized sludge
    2. BHydraulic washout
    3. CYoung sludge
    4. DSVI too low
  2. 2PROBLEM:
    Excessive white, billowing foam in the aeration tank surface.
    What is the MOST probable cause?
    1. ApH too high
    2. BMLSS too low
    3. CWaste temperature too high
    4. DWAS too low
  3. 3What happens in the stabilization (re-aeration) tank in the contact-stabilization process?
    1. AAdsorption of the activated floc
    2. BAdsorption of waste material by microorganisms
    3. CAgglomeration of the activated floc
    4. DAbsorption and digestion of the waste material collected by microorganisms
  4. 4PROBLEM:
    Good settling in the 30-minute settleability test. Excessive floc billowing in the clarifier and washing out. Sludge scrapers and RAS system appear normal. What is the BEST solution to fix the problem?
    1. ALower aeration tank effluent weirs
    2. BIncrease RAS
    3. CAdd chlorine to RAS
    4. DReduce clarifier hydraulic loading rates
  5. 5PROBLEM:
    Classic sludge bulking is occurring in the final clarifier of a conventional activated sludge plant. Indicators include: solids pouring over the weirs, excessive floc observed at the surface, and a homogenous (uniform) sludge blanket appearing throughout the clarifier. Sludge in settling test settles slowly leaving a cloudy supernatant with stragglers. What is the NECESSARY CHECK to confirm the cause?
    1. AWeir over flow rate
    2. BDetermine effluent suspended solids concentration
    3. CCalculate the sludge age
    4. DDO in aeration tank
  6. 6In a well operated activated sludge plant, when the RAS flow rate is decreased but the WAS flow rate remains constant, the expected conditions would be
    1. AMLSS Conc. F/M Ratio MCRT
      decreases increases decreases
    2. BMLSS Conc. F/M Ratio MCRT
      decreases decreases increases
    3. CMLSS Conc. F/M Ratio MCRT
      increases increases decreases
    4. DMLSS Conc. F/M Ratio MCRT
      increases decreases increases
  7. 7In an activated sludge plant, if the DO in the aeration tank suddenly decreases and the aerators are not the problem, what is the MOST PROBABLE cause?
    1. AF/M ratio decreased
    2. BIncreased organic load into tank
    3. CDenitrification occurring
    4. DMCRT too long
  8. 8PROBLEM:
    Upon arriving at the package treatment plant serving a small community, you find a uniform sludge blanket rising throughout the clarifier. A settleability test reveals a very slow-settling sludge leaving a very clear supernatant. MLSS test results are normal, but a calculation of the SVI shows a high sludge volume index. What is the MOST likely cause of the high sludge blanket?
    1. AThe operator has wasted too much sludge, causing a young sludge condition
    2. BAn extreme rain event washed out the majority of the solids
    3. CFilamentous bacteria are causing the slow settling
    4. DAn overdose of chlorine has killed the floc forming and filament bacteria
  9. 9PROBLEM:
    Solids are washing out of the secondary clarifier of the activated sludge plant. Plant personnel increase the return activated sludge (RAS) flow rate, which slows the problem temporarily, but then it worsens after 30 minutes. What is the cause of the plant problem?
    1. Aincreasing the RAS increased the detention time in the clarifier
    2. Bincreasing the RAS decreased the detention time in the clarifier
    3. Cincreasing the RAS increased the detention time in the aeration tank
    4. DiIncreasing the RAS caused the DO in the aeration tank to increase
  10. 10PROBLEM:
    Solids are washing out of the secondary clarifier of the activated sludge plant. A settleability test shows good settling CAN occur. The MOST likely cause of the problem is:
    1. AHigh flows are entering the treatment plant
    2. BThe RAS rate is too low
    3. CThe sludge collector mechanism is rotating counter-clockwise
    4. DDenitrification is occurring in the chlorine contact tank

Information

Description
Wastewater Public Utilities Quiz on Secondary Process & Troubleshooting, created by Dean Lampman on 10/03/2019.
Language
English
Views
150
History
Created on 10 Mar 2019 · updated on 12 Mar 2019
Rating
No ratings yet
Rate this quiz
Rate this quiz

Feedback

What is it about?

What do you think of the new look?

How do you like it?