Fire Detection and Alarm Systems

Joe Panuto 65 questions

Take the quiz

Questions in this quiz (65)

  1. 11. Who designs fire detection and alarm systems? (446)
    1. AA. Fire marshals
    2. BB. Code inspectors
    3. CC. Building engineers
    4. DD. Fire protection engineers
  2. 22. Which of the following components of a fire detection and alarm system is responsible for processing signals from detection devices and transmitting them to alerting devices? (447)
    1. AA. Smoke alarm
    2. BB. Power supply
    3. CC. System device
    4. DD. Fire alarm control panel (FACP)
  3. 33. Which of the following statements regarding a fire detection and alarm system dedicated branch circuit is MOST accurate? (448)
    1. AA. It must be easily accessible.
    2. BB. It must be marked in orange.
    3. CC. It must be mechanically protected.
    4. DD. It must be permanently identified as DEDICATED CIRCUIT.
  4. 44. A secondary power supply must be able to make the system fully operational within how long of the main supply’s failure? (448)
    1. AA. 15 seconds
    2. BB. 30 seconds
    3. CC. 1 minute
    4. DD. 2 minutes
  5. 55. Which of the following statements regarding system devices is LEAST accurate? (449-450)
    1. AA. They may be manual.
    2. BB. They may be activated by flame.
    3. CC. They may send a signal to the FACP by computer line.
    4. DD. They may utilize signaling devices such as strobe lights.
  6. 66. Which of the following statements regarding automatic alarm-initiating devices is LEAST accurate? (451-452)
    1. AA. They may detect both heat and smoke.
    2. BB. They continuously monitor the atmosphere of a structure.
    3. CC. Devices send a signal to the FACP when atmospheric changes are detected.
    4. DD. Smoke detectors are the only device that will not activate due to excessive moisture.
  7. 77. Which of the following is NOT a characteristic of fixed-temperature heat detectors? (452)
    1. AA. They are very expensive.
    2. BB. They are the slowest type to activate.
    3. CC. They are among the oldest in service.
    4. DD. They are the least prone to false activations.
  8. 88. Which of the following statements regarding fixed-temperature heat detectors is MOST accurate? (452)
    1. AA. They must be coded with pictographs.
    2. BB. They must be marked with listed operating temperatures.
    3. CC. They use one of five primary principles of physics to detect heat.
    4. DD. They must be placed in areas where heat is not likely to accumulate.
  9. 99. Which of the following components of fixed-temperature heat detectors holds a spring device in the detector in an open position? (453)
    1. AA. Fusible link
    2. BB. Wire clamp
    3. CC. Bimetallic strip
    4. DD. Frangible bulb
  10. 1010. In which of the following types of fixed-temperature heat detectors can two types of metal with different heat-expansion ratios be found? (454)
    1. AA. Duoburn
    2. BB. Bimetallic
    3. CC. Continuous-line
    4. DD. Fragmented-line