PNEUMATIC VAKIFBANK

Descripción

B737-678 PNEUMATIC
GlideSlope localizer
Test por GlideSlope localizer, actualizado hace más de 1 año
GlideSlope localizer
Creado por GlideSlope localizer hace casi 4 años
440
0

Resumen del Recurso

Pregunta 1

Pregunta
During a master caution light recall the right pack light illuminates?
Respuesta
  • Indicating a failure of other the primary or standby pack control
  • Indication the right air conditioning pack is in high flow
  • Indicating the left pack has been selected off and right pack may overloaded

Pregunta 2

Pregunta
The off sched descent light illuminates if...?
Respuesta
  • The aircraft has climbed selected flight altitude
  • The aircraft has descended before reaching selected flight altitude
  • The aircraft climbed above the selected flight altitude

Pregunta 3

Pregunta
The maximum differential pressure for positive relief valve operation is
Respuesta
  • 8,95 PSI
  • 8,15 PSI
  • 8 PSI

Pregunta 4

Pregunta
Right pack and zone controller consist of a?
Respuesta
  • Primary and standby controller for its respective pack
  • Primary controller on
  • Primary controller for its pack and standby controller for the other pack

Pregunta 5

Pregunta
İn case of clogging in water seperator in 737-700?
Respuesta
  • İndicator disc on the water seperator is in red range
  • Pack light amber illuminates
  • Duct overheat light amber illuminates

Pregunta 6

Pregunta
The purpose of the trim air pressure regulating valve is?
Respuesta
  • to provide fine adjustment of temperature of cabin zones
  • to regulate the hot air pressure 4 PSI more than the cabin pressure
  • to regulate the mass of air flow at the inlet packs

Pregunta 7

Pregunta
What are the conditions for e&e cooling fans operation?
Respuesta
  • The respective equipment cooling switch is in the supply/alternate position
  • The recirculation fan switch must be in the OFF position pack high flow
  • Both of pack switches must be off position the recirculation fan switch AUTO

Pregunta 8

Pregunta
In Boeing 737-600-700 aircrafts the right pack discharge overheat switch is located in?
Respuesta
  • E&e compartment
  • Distribution manifold in the cabin
  • Air condition mix bay

Pregunta 9

Pregunta
Boş
Respuesta
  • Boş
  • Boşş
  • Boşşş

Pregunta 10

Pregunta
The forward cargo compartment is warmed?
Respuesta
  • Only when the main outflow valve fully o..
  • At any time when more than 1 PSI difference pressure exist
  • In flight when more than 2,5 PSI difference

Pregunta 11

Pregunta
In auto pressurisation mode the cabin difference pressure for the off?
Respuesta
  • 0,10 PSI
  • 0,25 PSI
  • 0,125 PSI

Pregunta 12

Pregunta
The pressurization system controls airplane with?
Respuesta
  • A control panel, two cabin pressure control and two outflow valves
  • A control panel two cabin pressure control and one outflow valves
  • A control panel one cabin pressure control and one outflow valve

Pregunta 13

Pregunta
Why does the DUAL BLEED light illuminate?
Respuesta
  • When the APU Bleed valve is closed and the Engine bleed switches On
  • When the APU Bleed valve is open and the Engine bleed switches On
  • When the APU Bleed valve is closed and Engine bleed switches Off

Pregunta 14

Pregunta
If an OFF SCHED DESCENT light comes on the pressurization system will
Respuesta
  • Pressure the cabin back to the take-off airport altitude
  • Return the cabin to the last cruise altitude
  • Reschedule pressurization rate of change

Pregunta 15

Pregunta
The FWD DOOR area heater is located in the ?
Respuesta
  • On the left outboard side of the nose wheel well
  • Right side of the FWD cargo compartment
  • On the right inboard side of the nose wheel well

Pregunta 16

Pregunta
The bleed air duct pressure indicator?
Respuesta
  • Requires AC power for operation
  • Operates only when the CDU operating
  • İndicates both temperature and pressure in the duct

Pregunta 17

Pregunta
When using the pneumatic air CENT the battery switch?
Respuesta
  • Must be on and air conditioning pack sw on
  • Must be on or off when using aircraft air conditioning
  • Must be on a d air conditioning pack switches off

Pregunta 18

Pregunta
Where is the receptacle for external compressed air?
Respuesta
  • Lower left side of the fuselage
  • Upper right side of the fuselage
  • Lower right side of the fuselage

Pregunta 19

Pregunta
The TRIP RESET switch on the -800-900 airconditioning panel will reset the?
Respuesta
  • BLEED TRIP OFF, DUCT OVERHEAT and ZONE TEMP lights provided the fault condition has been corrected.
  • DUCT OVERHEAT, PACK and ZONE TEMP lights provided the fault condition has been corrected
  • BLEED TRIP OFF, PACK, ZONE TEMP lights provided the fault condition has been corrected

Pregunta 20

Pregunta
What input required of the pilot for pressurization auto control system to function property?
Respuesta
  • Cruise altitude and landing altitudfe
  • Cruise altitude and take-off altitude
  • Landing altitude only

Pregunta 21

Pregunta
After the overheat lights illuminated during OVERHEAT test?
Respuesta
  • Action is required as the resetting of the system on the window heat computer
  • No action is required as the resetting of system automatic
  • The window heat switches must be momentraily positioned to off to rest the system

Pregunta 22

Pregunta
When one air conditioning pack switch selected to HIGH?
Respuesta
  • Related pack will regulate to LOW FLOW with flap extend
  • Flap selection has no effect on the low flow rate of that pack
  • The operating pack will regulate to high flow only with flaps up

Pregunta 23

Pregunta
If the external pressure exceeds the internal pressure the ... will open?
Respuesta
  • Overboard exhaust valve
  • Negative pressure relief valve
  • Positive pressure relief valve

Pregunta 24

Pregunta
The CONT CAB amber ZONE TEMP light illuminate with recall indicates?
Respuesta
  • Primary or Standby pac controller failure
  • Primary pack controller failure
  • Primary and stanby pack controller failure

Pregunta 25

Pregunta
The APU will switch into a HIGH FLOW rate then?
Respuesta
  • The flaps are down
  • Both engine bleed air switches are selected OFF regardless of flap position
  • The airplane is on ground

Pregunta 26

Pregunta
When the Rİght Pack switch OFF and the isolation valve switch is in AUTO, the isolation valve will?
Respuesta
  • Open
  • Closed
  • Modulate

Pregunta 27

Pregunta
The RH Pack/Zone Temperature controller?
Respuesta
  • Controls the flight deck and provides back up control for the aft cabin
  • Controls the flight deck and fwd cabin
  • Controls the fwd cabin and provides backup control for the flight deck

Pregunta 28

Pregunta
Burnination of the amber Bleed Trip Off light indicates ... has automatically closed?
Respuesta
  • Pressure REgulating and Shut Off valve
  • Isolation valve
  • Apu bleed valve

Pregunta 29

Pregunta
The lh pack zone temperature controller?
Respuesta
  • Controls the FWD cabin and provides backup control for the aft cabin
  • Controls the FWD cabin and provides backup control for the flight deck
  • Controls the AFT cabin and provides back up control for the flight deck

Pregunta 30

Pregunta
Trim Air Modulating Valves are controlled by?
Respuesta
  • The pressure controllers for the fine adjustment of temperature
  • The pack controllers for the basic temperature regulation
  • Two pack zone controllers for thefine adjustment of temperature

Pregunta 31

Pregunta
With one air conditioning pack sitch selected to high?
Respuesta
  • The pack will regulate to LOW FLOW with flap extended
  • Flap sekection has ne effect on the flow rate of that pack
  • The operating pack will reguate o HIGH FLOW only with glaps up

Pregunta 32

Pregunta
In 737-700 series aircraft the air mix valve?
Respuesta
  • Pneumatically controlled
  • Electrically operated
  • Pneumatically operated, electrically controlled

Pregunta 33

Pregunta
When the PACK TRIP OFF (amber) light illuminates in 737-700 aircraft?
Respuesta
  • THe hot butterfly of airmix valve opens automatically
  • Flow control and shut off valve closes automatically
  • Low limit valve closes automatically

Pregunta 34

Pregunta
In 737-600/700 rh pack discharge overheat switch is located in
Respuesta
  • E/E compartment
  • Distribution manifold in the cabin
  • Air condition mix bay

Pregunta 35

Pregunta
If the AMBER AUTO FAIL light illuminates on the pressurization panel?
Respuesta
  • Positioning the Pressure Mode Selector to alternate will extinguish the AUTO FAIL light
  • It will automatically extinguis when the pressurization controllers reverts the alternate mode
  • Positioning the Pressurization mode selector to alternate will have no effect on the AUTO FAIL light

Pregunta 36

Pregunta
The OUT FLOW valve has ?
Respuesta
  • Two motores each controlled by a decide cabin pressure controllers
  • Three motors controlled by a CPC
  • Three motors, two automatically one manually controlled

Pregunta 37

Pregunta
Which of the following overheat switches or overtemperature sensors detect and overheat condition when a pack light illuminates?
Respuesta
  • Compressor discharge overheat switch,ü turbin inlet overheat switch 190F/88c duct overheat switch or duct limit sensor
  • Compressor discharge overheat switch, turbine inlet overheat switch 190f/88c duct overheat switch
  • Compressor discharge overheat switch, turbine inlet overheat switch or pack discharge overheat switch

Pregunta 38

Pregunta
The PITOT PROBE HEATERS lights are?
Respuesta
  • Amber in color and associated with the system
  • Not associated with the Master Caution
  • Illuminated when heat is being supplied pitot static and probe heaters

Pregunta 39

Pregunta
The High Stage Modulating and Shut Off valve?
Respuesta
  • Is opened at all times irrespective of 5th stage air pressure output
  • Will open if the 5th stage air pressure is insufficent
  • will open if the APU bleed air pressure is insufficient

Pregunta 40

Pregunta
Standby temperature control valve is ?
Respuesta
  • Fully controlled PACK/ZONE controller
  • Electrically controlled and operated
  • Either electrically controlled or pneumatically controlled

Pregunta 41

Pregunta
Where is the flight compartment 190F/88c duct overheat switch located? (600-700)
Respuesta
  • Distribution compartment
  • E/E compartment
  • LH airconditioning compartment

Pregunta 42

Pregunta
The cowl ANTI-ICE light is?
Respuesta
  • Amber in clour indicating over temp or over pressure
  • Blue colur and when illuminated indicates the engine cowl anti-ice valve is in disagreement with the engine anti-ice switch
  • Amber in colour indicating overpressure only

Pregunta 43

Pregunta
For 800/900 what controls the operating of the temperature control system
Respuesta
  • The cabin temperature controller only
  • The temperature controller panel and air conditioning bleed air control panel
  • The temperature control panel , the ACAU and PACK/ZONE Temperature Controller

Pregunta 44

Pregunta
The maximum external air pressure (ground cart)
Respuesta
  • 30 PSI (at 231C)
  • 40 PSI (at 231C)
  • 60 PSI (at 231C)

Pregunta 45

Pregunta
A pack Lİght illuminates in flight (without recall)
Respuesta
  • The standby pack has failed but the primary control is operational
  • The primary pack has failed but the standby control is operational
  • Both primary and standby pack controls have failed.

Pregunta 46

Pregunta
An engine Bleed Trip OFF light will illuminate
Respuesta
  • When engine bleed air temperature or pressure exceeds a predetermined limit
  • Only if engine bleed air pressure exceeds a predetermined limit
  • Only if engine bleed air temperature exceeds a predetermined limit

Pregunta 47

Pregunta
The wing Anti-ice control valve_
Respuesta
  • are DC motor operated
  • are AC motor operated
  • are pneumatically operated

Pregunta 48

Pregunta
With ISOLATION VALVE switch AUTO both ENG BLEED sw ON and BOTH Air Cond Pack sw selected AUTO or HIGH?
Respuesta
  • The ISOLATION VAlVE will be closed
  • The ISOLATION VAlVE will be opened
  • The ISOLATION VAlVE will be closed when the flaps are extend

Pregunta 49

Pregunta
If the ACM compressor discharge overheat switch activated this?
Respuesta
  • Commands the RAM AIR system full close
  • Close the PACK FLOW CONT SOV and PACK light on
  • Causes the pack to go to a HIGH FLOW mode of operation

Pregunta 50

Pregunta
THe total air temperature probe
Respuesta
  • Does not required heating
  • Its electrically heated
  • It is not heated while on ground

Pregunta 51

Pregunta
When the pack discharge reaches 250f/121c (overheat) to reset the Air Conditioner sys?
Respuesta
  • Push the P5 trip reset switch
  • Select the pack switch to HIGH or AUTO
  • Reset is automatic

Pregunta 52

Pregunta
When you use the wing theamal anti-icing system on the ground?
Respuesta
  • De-icing fluids are not necessary
  • There is no protection to prevent heating leading edge overheat conditions
  • THe WTAI selenoid bleeds control pressure from the Precooler Control Valve

Pregunta 53

Pregunta
Which is feed into WTAI? Pneumatic system
Respuesta
  • True
  • False

Pregunta 54

Pregunta
Pack'lerin AUTO dan HİGH a geçmesi için? Flaps up
Respuesta
  • True
  • False

Pregunta 55

Pregunta
Duct temp 88C ? Zone TEMP
Respuesta
  • True
  • False

Pregunta 56

Pregunta
PRSOV closes when? Pressure is 220 PSI
Respuesta
  • True
  • False

Pregunta 57

Pregunta
Ground cart supply pressure? 60 PSI
Respuesta
  • True
  • False

Pregunta 58

Pregunta
Isolation valve operate? AC
Respuesta
  • True
  • False

Pregunta 59

Pregunta
Compressor 9th stage? High pressure
Respuesta
  • True
  • False

Pregunta 60

Pregunta
E/E ventilation? Equipment ventilation (cooling)
Respuesta
  • True
  • False

Pregunta 61

Pregunta
Wiper how does operate? With knob rotary
Respuesta
  • True
  • False

Pregunta 62

Pregunta
Cabin altitude aural warning when? 10.000 feet
Respuesta
  • True
  • False

Pregunta 63

Pregunta
Air comes to precooler where? Fan
Respuesta
  • True
  • False

Pregunta 64

Pregunta
ANTI-ICE Heater test? HEATER sw ON
Respuesta
  • True
  • False

Pregunta 65

Pregunta
Pack switch positions? OFF-AUTO-HIGH
Respuesta
  • True
  • False

Pregunta 66

Pregunta
Outflow valve manual controls? OPEN-CLOSE
Respuesta
  • True
  • False

Pregunta 67

Pregunta
Positive pressure relief valve? 8,95 PSI
Respuesta
  • True
  • False

Pregunta 68

Pregunta
What is the PACKs purposes? Basic temperature
Respuesta
  • True
  • False

Pregunta 69

Pregunta
ACAU? 2 ea
Respuesta
  • True
  • False

Pregunta 70

Pregunta
Window heater? Interchangable
Respuesta
  • True
  • False

Pregunta 71

Pregunta
OFF SCHED DESCENT LIGHT? Take off airport altitude
Respuesta
  • True
  • False

Pregunta 72

Pregunta
PITOT heats? 115v ac
Respuesta
  • True
  • False

Pregunta 73

Pregunta
RAM AIR actuator? 115v ac
Respuesta
  • True
  • False

Pregunta 74

Pregunta
Wing thermal Anti Ice? Thrust levers more than 60 degree system doesnt operate. Wing Anti Ice ground thermal on switch iki kanat valflerini de kapatır.
Respuesta
  • True
  • False

Pregunta 75

Pregunta
9th stage 110 PSI ? High stage fully close
Respuesta
  • True
  • False

Pregunta 76

Pregunta
490 F (254 C) ? PRSOV close
Respuesta
  • True
  • False

Pregunta 77

Pregunta
Flow control and Shut off valve ? Selenoid A= APU/HIGH flow operation Selenoid B= LOW and HIGH flow Selenoid C= Open close valve
Respuesta
  • True
  • False

Pregunta 78

Pregunta
Isolation valve position? Auto-Close
Respuesta
  • True
  • False

Pregunta 79

Pregunta
Cocpit air? LH PACK
Respuesta
  • True
  • False

Pregunta 80

Pregunta
TAI ? Shows N! indicator- Green
Respuesta
  • True
  • False

Pregunta 81

Pregunta
Duct pressure indicator? P5 panel
Respuesta
  • True
  • False

Pregunta 82

Pregunta
PACK light? ACAU
Respuesta
  • True
  • False

Pregunta 83

Pregunta
Positive relief valve? Pneumatic
Respuesta
  • True
  • False

Pregunta 84

Pregunta
Recirculation fan? 115v 3 phase
Respuesta
  • True
  • False

Pregunta 85

Pregunta
Duct temp 88 üstü? ZONE TEMP light
Respuesta
  • True
  • False

Pregunta 86

Pregunta
LOW LIMIT sensor? Equipment cooling supply and exhaust
Respuesta
  • True
  • False

Pregunta 87

Pregunta
Packler AUTO da bir Pack HIGH a geçmesi için? Flaps up
Respuesta
  • True
  • False

Pregunta 88

Pregunta
737-600-700 duct temp 88 C? DUCT OVHT light
Respuesta
  • True
  • False

Pregunta 89

Pregunta
737-800/900 DUCT TEMP 88C ? ZONE TEMP light
Respuesta
  • True
  • False

Pregunta 90

Pregunta
Compressor çıkış sıcaklığı 199 C? Pack light yanar
Respuesta
  • True
  • False

Pregunta 91

Pregunta
PRSOV ne zaman kapalıya gider? Basınç 220 PSI
Respuesta
  • True
  • False

Pregunta 92

Pregunta
TAI amber light N1? Valve position not agree more than 8 second
Respuesta
  • True
  • False

Pregunta 93

Pregunta
Cowl Anti-Ice amber light? Overpressure only
Respuesta
  • True
  • False

Pregunta 94

Pregunta
Cabin altitude pressure switch? Cabin altitude reached 10000
Respuesta
  • True
  • False

Pregunta 95

Pregunta
Precooler sensor nerede? ENG Strut Duct
Respuesta
  • True
  • False

Pregunta 96

Pregunta
Ground thermal WTAI Sensor? Downstream of WTAI
Respuesta
  • True
  • False

Pregunta 97

Pregunta
Door heating system? -Any pack on -Arcraft on air
Respuesta
  • True
  • False

Pregunta 98

Pregunta
Heat exchanger blokage? RAM DOOR FULL OPEN blue light on
Respuesta
  • True
  • False

Pregunta 99

Pregunta
Duct pressure transmitter? Air cond bay
Respuesta
  • True
  • False

Pregunta 100

Pregunta
Flight Compartment? LH PACK
Respuesta
  • True
  • False

Pregunta 101

Pregunta
During ENG start? PRSOV close
Respuesta
  • True
  • False

Pregunta 102

Pregunta
Cargo blowout panels? 1 PSI differenatial pressure
Respuesta
  • True
  • False

Pregunta 103

Pregunta
TRIP RESET? -ZONE TEMP -BLEED TRIP OFF -PACK
Respuesta
  • True
  • False

Pregunta 104

Pregunta
Overheat Switches? -comp. discharge -turbine inlet switch -pack discharge
Respuesta
  • True
  • False

Pregunta 105

Pregunta
Trim Air Regulating Shut Off valve? +4 PSI Cabin air
Respuesta
  • True
  • False

Pregunta 106

Pregunta
Recirculation system? Fuel save
Respuesta
  • True
  • False

Pregunta 107

Pregunta
Recirculation fans? Ground= LH Recirc. FAN BOTH PACK HIGH FLOW iken çalışmaz diğer tüm şartlarda yerde çalışır. RH Recirc. FAN yerde her zaman çalışır Air= LH Recirc. FAN herhangi PACK HIGH da ise çalışmaz RH Recirc. FAN iki PACK HIGH ise çalışmaz
Respuesta
  • True
  • False

Pregunta 108

Pregunta
-600/700 Aircodition? 1 CTC 1 ACAU 1 CONTROL PANEL
Respuesta
  • True
  • False

Pregunta 109

Pregunta
RH PACK ZONE CONTROLLER? -Flight compartment -FWD pass. cabin
Respuesta
  • True
  • False

Pregunta 110

Pregunta
NGS Shut Off valve? Center Tank Re-Fuel Valve closed
Respuesta
  • True
  • False
Mostrar resumen completo Ocultar resumen completo

Similar

How well do you know GoConqr?
Sarah Egan
Common Technology Terms
Julio Aldine Branch-HCPL
The Aviation Industry
jameskelsall
Robots
dave_lunt2
Construction technology cards
Fred Fulford
IATA Report: The Impact of September 11 2001 on Aviation
Sarah Egan
Airport & Aviation
Sahar Al Mughairi
Aviation Domain Laws and Regulations
Maddi Cullen
South West Airlines.
Lyndah Kiki Jabe