¡GoConqr estrena diseño! Cuéntanos qué te parece.

Mapa mental

Gradients

Kristi Brogden BMS 381 Developmental neurobiology Undergraduate Inglés

Gradients

Contenido del mapa

Gradients

  1. Gradients can act over long distances

    • In mammals, the majority of C axons turn rostrally after Xing the floor plate. What determines this?
      • One possibility is an A-P gradient of either an attractant or a repellant, which could be a long range diffusible cue
        • or a short range, non-diffusible.
        • How can we distinguish between these possibilities?
          • Could distinguish by culturing large vs small explants:
        • Evidence for a long range attractant
          • Prediction is that a relatively small explant will lose its gradient if the chemotropic agent is diffusible (whereas a larger explant will not), which should not be true if the guiding factor is non-diffusible
            • Also, in larger explants, expect anterior-most axons to turn aberrantly if attractant, but posterior-most axons if repellant (think about it!)
        • If a repellant…
  2. Detecting gradients

    • Two ways in which to measure a gradient
      • Change of concentration over time (temporal detection) - cell must compare amount of ligand at two different time points
      • Change of concentration across the cell (or growth cone; spatial detection) - cell must compare the amount of ligand at two different points on it surface.
        • For slow-moving eukaryotic cells (ie not bacteria) spatial detection likely to be most important.
      • Most of what we know has come from studies of the chemotaxis of white blood cells (neutrophils and leukocytes) and the slime mould Dictyostelium
    • Accuracy of orientation
      • Accuracy of orientation towards a source depends on:
        • Absolute concentration of the chemoattractant - most accurate closest to the KD (dissociation constant) of the receptor*.
          • * At the KD concentration, half of the receptors will be occupied giving greatest capacity for detecting increases or decreases in receptor occupancy
        • Steepness of the gradient
      • Gradient is expressed as % change per micron (µm)
        • Leukocytes only orient with accuracy when gradient is ≥0.2%, e.g. 2% change over a 10µm diameter
          • Note that larger diameter cells orient more accurately than small cells in shallow gradients
            • Recent studies indicate that neurons have similar characteristics
    • Mechanisms to enhance range over which gradients can be detected
      • Even relatively steep gradients (2% over 10µm) require very small differences in receptor occupancy to be detected across the growth cone.
        • In mid-gradient, a growth cone with, say, 1000 receptors would require the cell to detect a difference of just 5 occupied receptors across its width for such a gradient (250 x 1.02):
  3. Amplification and adaptation

    • Two methods to enhance sensitivity of GCs to gradients
    • Amplification
      • Amplification requires local enhancement of signal together with inhibition of signal reception in other parts of the cell
        • One suggested mechanism involves clustering of receptors and/or signalling components in regions where receptors activated by transporting components from other parts of the cell:
          • Evidence for clustering of downstream components can be found in chemotaxing Dictyostelium…
            • Chemoattractants in leukocytes and Dictyostelium activate PI3Kinase via a G-protein coupled receptor (GPCR)
              • Chemoattractant detected by a GPCR (7TM protein)
              • This activates PI3kinase, which then phosphorylates PI(4,5)P2 (PIP2) to give PIP3 (PI(3,4,5)P3)
              • This provides a docking site for proteins containing Pleckstrin Homology (PH) domains, (such as Akt), creating a localised signalling domain on the membrane
              • Note that PI3K activity is antagonised by PTEN phosphatase
                • This is critical to ensure that signals are highly localised and labile, dependent on continued external activation….
            • Recruitment of PH domain proteins to leading edge of chemotaxing cell
              • See ppt
      • Amplification: primes machinery to ‘test’ cue found?
    • Adaptation
      • If growth cones operate most discriminatively when the chemoattractant concentration is closest to the receptor KD, then clearly receptors will saturate as concentration increases.
        • Simple calculations show that even the shallowest gradients required to turn cells (0.2% per µm) will result in 90% receptor occupancy just 250µm from the optimal ligand concentration.
          • In other circumstances - e.g. synaptic transmission - signal saturation leads to desensitization and resetting of thresholds (or resensitization if signals fall).
            • Is there evidence for such ‘adaptation’ in responses to gradients?
              • Frog axon turning assay
              • Adaptation in response to netrin?
                • Pulsed netrin forms an exponential gradient which is revealed by including a fluorescent marker in the pipette
                  • Growth cones responding to such a gradient initially exhibit a ‘zig-zagging’ trajectory
                    • The alternating attractive and repulsive turning suggests cycles of desentization and sensitization of the growth cone to netrin.
              • Growth cones adapt to chemoattractants
                • To determine whether growth cones adapt to increasing attractant concentrations, Ming et al pretreated axons with differing concentrations of netrin:
                  • They discovered that immediately (30min) after treatment, growth cones no longer responded (b)
                    • However, after a longer period (90mins), growth cones resensitized (c)
                      • This resensitization was dependent upon MAPKinase activation and local protein synthesis in the growth cone.
                        • Responses to Sema3A are subject to similar adaptation (see Piper et al 2005)
                • See ppt
  4. Stretching gradients to the limits

    • Over what distance could growth cones be guided by gradients?
      • Depends upon the the shape of the gradient, which depends on how it is set up:
        • Diffusible molecules e.g.
          • Wnts: expression gradient along axis
          • Netrins: point source (floor plate)
        • Non-diffusible molecules e.g.
          • Ephrins (tectum): surface bound molecules expressed in gradients
        • These two different types of gradient have inherently different ranges of action (discussed in Goodhill (1998). Trends Neurosci 21: 226-31)….
    • Two different types of gradient
      • Point source
        • A gradient set up by diffusion from a point source (such as that used by Ming et al) - typically an exponential gradient - has a theoretical maximum range of 1mm, which corresponds well to supposed point source ranges in vivo:
        • Point sources depend on:
          • a limited diffusion rate.
          • some mechanism for removing the guiding molecule - a ‘sink’ - otherwise gradient will flatten with time (depending on diffusion rates)
      • Linear substrate bound gradients
        • can be longer
        • By contrast, a substrate bound gradient, typically more linear in shape, has a theoretical maximum range of close to 1cm.
          • Again, this corresponds well with what is observed in vivo.

Imágenes y archivos del mapa

  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients
  • Gradients

Información

Descripción
Undergraduate (AF lectures) BMS 381 Developmental neurobiology Mapa Mental sobre Gradients, creado por Kristi Brogden el 30/10/2014.
Creado por
Kristi Brogden · oct 2014
Actualizado
19 feb 2016
Visitas
9
Valoración

Escríbenos

¿Sobre qué es tu mensaje?

¿Qué te parece el nuevo diseño?

¿Te gusta?