¡GoConqr estrena diseño! Cuéntanos qué te parece.

Test

practice test

Yadira Acosta 75 preguntas

Hacer el test

Preguntas del test (75)

  1. 1Which of the following BEST describes a referential montage?
    1. AThere is potential for electrode contamination.
    2. BLocalization is by phase reversal.
    3. CImpedance values are less important.
    4. DCommon mode rejection will no be effective.
  2. 2The ability to remontage while recording on digital equipment is the result of
    1. ASystem referencing
    2. BOut of phase cancellation
    3. CSignal processing
    4. DCommon mode rejection
  3. 3According to RECOMMENDED guidelines, the minimum duration of a significant leg movement is:
    1. A5 seconds
    2. B1 second
    3. C.1 second
    4. D.5 second
  4. 4The MOST COMMON method to monitor blood oxygen saturation during polysomnography is:
    1. AArterial blood gas
    2. BEnd-tital CO2
    3. CPulse oximetry
    4. DCapnography
  5. 5What intermittent 60 Hz activity occurs in the F4-M1 electrodes during REM sleep the BEST IMMEDIATE action would be to:
    1. AChange F4 electrodes
    2. BDocument and continue recording
    3. CRely on F3-M2
    4. DChange M1 electrode
  6. 6The electrode located 30% above the left pre-auricular crease is:
    1. AF3
    2. BO1
    3. CP3
    4. DC3
  7. 7The activity in the respiratory channels is BEST described as:Imagen de la pregunta 7
    1. APulse
    2. BECG
    3. C60 Hz
    4. DCardioballistic
  8. 8The MOST appropriate setting a technologist would use to control the frequency band of waveforms on a recording is the:
    1. ALow filter
    2. BSampling rate
    3. CSensitivity
    4. DDisplay gain
  9. 9According to RECOMMENDED guidelines, unattended portable monitoring can be used as an alternative to in-lab testing when:
    1. AThere is a high probability of moderate to severe OSA without comorbid conditions.
    2. BThe patient is unable to complete a comprehensive sleep evaluation.
    3. CComorbid disease processes make in-lab study difficult
    4. DDifferentiating RBD from OSA
  10. 10When the amplitude of a signal exceeds the physical limitations of a channel the MOST important adjustment the technologist can make to optimize waveform display is to:
    1. AIncrease display gain
    2. BDecrease sampling rate
    3. CIncrease HLF
    4. DDecrease sensitivity

Información

Descripción
Test sobre practice test, creado por Yadira Acosta el 02/06/2019.
Idioma
English
Visitas
77
Valoración
Aún sin valoraciones
Valora este test
Valora este test

Escríbenos

¿Sobre qué es tu mensaje?

¿Qué te parece el nuevo diseño?

¿Te gusta?