- 1how many sets of boots does the AC have6
- 2how many deice boots are there on the wings12
- 3how many engine intake boots are there2
- 4how many vertical stabiliser boots are there2
- 5how many horizontal stabiliser boots are there4
- 6what is the normal position of the isolation valve in the bleed systmemopen
- 7what is the system pressure of the deicing system18 +/- 3 psi
- 8when does a light indication come on15 psi
- 9how many distribution valves are there6
- 10how many pressure transducers are there2 on each side
- 11during auto operation how long does each set of boots activate for6 seconds
- 12in slow mode what is the dwell period144 seconds
- 13in fast mode what is the dwell period24 seconds
- 14when in manual how is operation controlledselect each set of boots for 6 seconds,and have a dwell period of 24 seconds
- 15what does the gauge showthe pressure in the L and R systems
- 16in normal operation what does the gauges showthe same for the l and r systems
- 17how can the L and R boot air systems be isolatedby the boot air switch
- 18why would you want to split the L and R systemshelps identify faults and retains the pressure in the unaffected side
- 19what does the splitting of the systems allow forallows tail and intake boots to be operated in the event of a system leak
- 20what is the only direction that manual should be operated inanticlockwise
- 21how are the valves heated in manual modeall at the same time
- 22how do ice detection probes workice on probes alters frequency
- 23what will happen if ice is detected and the REF SWITCH is not selected to INCRICE DETECTED message will flash orange on the ED
- 24how long is the ice detected message illuminated for5 seoncds
- 25what is the indication if the ref speed switch has been selected to INCRwhite on black background REF speeds
- 26what happens if you get a dual ice protection system faultit will activate a CWP caution
- 27what happens if a single ice protection system fails?it is recorded in the Central diagnostic System
- 28what does the ice protection spigot indicatethe ice that is accumulating on the tail
- 29how much of the prop is deiced70%
- 30when is AC power onprop RPM above 400
- 31what power does the system need for prop deicingAC
- 32describe how the prop deicing test is doneNp (Condition Levers above minimum)
Prop switch held at TEST
Each light on for 7 seconds
Wait 30 seconds before repeating, should you need to - 33what is the limitation for the min temp required to ensure air inlet ice protection in flight65 degrees C
- 34what is the limitation for the min oil temp required for entering in flight icing condition and within what time period should it reach the higher temperature55 degrees C
but must reach 65 within 3 mins of setting takeoff power - 35what does selecting prop heat on doresets the low oil temp amber arc from 0 to 55
the gauge changes - 36what are the two positions on the Ref speed switch buttonINCR and OFF
- 37what does the REF speed switch doincreases the stick shaker activation datum by 20 kts
- 38how can you know if the REF SPEED button is on INCRby looking at the ED and seeing the message
INCR REF SPEED in WHITE - 39what warning will you get that you need to put the switch to INCRice detected message in AMBER
- 40what speeds are the 20 kts added toVMIN and the stick shaker
- 41what is added to VREFan increment dependant on flap setting
- 42what do you have to leave open when leaving icing conditions that wouldn't be on if you didn't enter icing conditions in the first placethe engine intake door
- 43what is the definition of icing in the airSAT 5°C or LESS
and visible moisture - 44what does the ground levers advancing on the ground dopre pressurise the ac
- 45what positions can the ENGINE INTAKE SWITCHLIGHT be inOPN
CLSED
HEATER - 46what does the heater light indicatethat the engine intake heater is active
- 47what does pressing the ENGINE INTAKE SWITCH LIGHT doopens the doors and arms the heaters
- 48What conditions are needed for the heaters to activateOAT 15°C or below
AND
oil pressure above 44 psi - 49how many pitot static probes are on the FOs side2
- 50what are #1 and #2 pitot static probes heated byrelative AC Busses
- 51when do the AoA heaters operatewhen the 115 V AC buses energise
- 52when would the windshield and PLT side window heat be set to NORMafter TO is SAT above 20 degrees