Flashcards
Chapter 11: Evaluation of Prosthetic Valves

Cards in this deck (46)
- 1Evaluation of Prosthetic ValvesSimilar in many respects to native valves
- 2Different types of prosthetic valves have differing...??Fluid dynamics
- 3Different valve sizes have differing...??Flow velocities
- 4Mechanism of valve dysfunction is...??Different than with native valves
- 5Echo structures are hard to visualize due to-Acoustic Shadowing
- 6Echo eval must include:specific flow dynamic for
size and type of prothesis
in an individual pt - 7Tissue Valves (Bioprostheses)Three leaflets
Constructed similar to native valves - 8Porcine Tissue ValveLeaflets
- 9Bovine/Equine Tissue ValvesPericardium
- 10Homograft ValvesCryopreserved human aortic or pulmonic valves harvested at autopsy
- 11Mechanical ValvesBileaflet and Tilting Disk
- 12—Carpentier-Edwards Perimount AV

- 13—St. Jude Trifecta Valve

- 14—Medtronic Stentless Freestyle Valve

- 15Ballon expandableTranscatheter AV Bioprosthesis

- 16—Bileaflet Valve
St. Jude Medical Regent Valve
- 17—Tilting-Disk Valve
Medtronic-Hall Valve
- 18—Star Edwards Ball and Cage Valve

- 19—Star Edwards Ball and Cage Valve Echo

- 20—Fluid dynamics. Bileaflet has best flow

- 21Surgical Bioprosthetic AVR:Antegrade Flow: <3 m/s
No-to-trace central AR - 22Transcatheter Bioprosthetic:Antegrade Flow: <3 m/s
Mild valvular or Paravalvular AR - 23Mechanical AVR:Antegrade Flow: <3 m/s
Mild eccentric AR due to occluded closure - 24Bioprosthetic MVR:Antegrade Velocity: <1.9 m/s
Short T 1/2
No-to-trace central MR - 25Mechanical MVR:Antegrade Velocity: <1.9 m/s
Short T 1/2
Mild eccentric MR due to occluded closure - 26Surgical Bioprosthetic AVR ComplicationsLeaflet degeneration
Stenosis
Regurgitation
Pannus in growth
Paravalvular AR
Endocarditis - 27Transcatheter Bioprosthetic ComplicationsLeaflet degeneration
Stenosis
Regurgitation
Pannus in growth
Paravalvular AR - 28Mechanical AV ComplicationsValve Thrombosis
Pannus in growth
Paravalvular AR
Endocarditis - 29Bioprosthetic MVR ComplicationsLeaflet degeneration
Stenosis
Regurgitation
Pannus in growth
Paravalvular MR
Endocarditis - 30Mechanical MVR ComplicationsValve Thrombosis
Pannus in growth
Paravalvular MR
Endocarditis - 31—Bileaflet Mechanical MV
DIASTOLE: two parallel openings
SYSTOLE: sewing ring
- 32—Bileaflet Mechanic MV CF
DIASTOLE: two large orifices
SYSTOLE: two normal jets or regurgitation
- 33Bioprosthetic Structural Failureprogressive fibro calcific degeneration leads to stenosis and/or regurgitation, PVL, and dehiscence
- 34Mechanical Structural Failurefaulty design, wear and tear, pannus ingrowth, thrombus, PVL, and dehiscence
- 35Thromboembolic ComplicationsMechanical valves are prone to clot
Echo cannot exclude clot due to shadowing and reverberation - 36EndocarditisResults in vegetations that affect bioprosthetic leaflets and paravalvular area of prosthetic valve
- 37—Prominent closing valve clicks
Increased antegrade vel with steep PHT
Triangular CW envelope
- 38GuidelineBaseline echo 3 months post implantation to rule out mismatch
- 39Pt Prosthesis MismatchImplanted valve is relatively small to the pt's body size
- 40Baseline EchoDistinguish progressive stenosis due to mechanical failure from mismatch
- 41Prosthetic Valve RegurgNormal: small amount of regurg
- 42Pathological RegurgitationEccentric/Large jet
Marked variance on CF
Jet originating from the sewing ring
Proximal flow acceleration region on LV
Increased RVSP (MR)
Holodiastolic flow reversal in Desc Ao (AR)
Intensity/Shape of CW
VCW - 43—PVLs

- 44—Stented Tissue Prosthetic MV Vegetation

- 45—Bioprosthetic AS

- 46—
Information
- Description
- Flashcards on Untitled, created by Tamar Corral on 14/11/2023.
- Created by
- Tamar Corral
- Views
- 4
- Rating