Help shape GoConqr. What should we add next?

Flashcards

GH Probes, tracer particles

Jack Moule Lasers and Optical Measurements Masters English 18 cards

Cards in this deck (18)

  1. 1Purpose pitot static probeMeasures fluid velocity
  2. 2How pitot static probe worksConverts kinetic energy of the flow into potential energy at the stagnation point at the pitot tube entrance.
    A pressure higher than the free stream results from the conversion.
    A differential manometer measure the difference between the dynamic and static pressures
  3. 3Good /bad pitot-static probesSimple and easy to use
    Slow operation speed - low frequency response
    Intrusive - changes flow
  4. 4Thermal or hot wire AnemometryThin wire mounted on supports has a current pasing through it causing it to heat up.
    Heat input balanced by heat loss from flow
  5. 5Hot wire Anemometry Assumptions1. Radiation losses small
    2. Conduction to supports small.
    3. Fluid temperature uniform over the length of the sensor.
    4. Velocity impinges normally on wire, uniform over length, small compared to sonic speed.
    5. Fluid temp and density constant.
  6. 6Good/Bad Hot Wire AnemometryHigh accuracy point measurement
    High-frequency response
    Intrusive and contamination error
  7. 7Optical DiagnosticsNon intrusive measurement of velocity, species concentration, temperature, pressure.
    Harsh environments
    Can record high speed events
  8. 8LDA, PDA, PIVLaser Doppler Anemometry - Point measurement velocity
    Phase Doppler Anemometry - Point measurement of velocity and particle diameter
    Particle Image Velocimetry - Velocity field mapping in 2D and 3D via Imaging techniques
  9. 9Dual beam doppler technique1. Light from single laser split into 2 beams and focused to intersect at a point of interest in the seeded flow.
    2. Scattered light from the intersection is collected and focussed into a detector.
    - scattered light from both beams reaches the detector simultaneously, signal on the detector the beat frequency - representing the difference between the individual doppler shifts
  10. 10Beat Frequencybeat frequency - representing the difference between the individual doppler shifts
  11. 11Why need tracers?Particles smaller than the wavelength of light do not scatter the light.
    Tracers are bigger particles that can scatter the light allowing LDA to be carried out.
  12. 12Requirements for tracer particles1. Follow the flow sufficiently accurately for the flow to be studied (small enough)
    2. Scatter sufficient light to give an acceptable signal to noise ratio (large enough)
    Both must be satisfied
  13. 13Turbulent flow development1. Viscous forces between high speed particles and stagnant air cause the particles to slow down.
    2. This causes the flow to roll up into eddies.
    3. This creates further shear force generating more eddies and turbulence.
    4. A point is reached where the viscosity dissipates the kinetic energy.
  14. 14Kolmogorov length scaleThe length scale giving the smallest eddies in the flow which can be used to determine the largest flow frequency the particles need to follow.
  15. 15Integral length scaleLargest eddies
  16. 16How are the size of the tracer particles determined?1. Kolmogorov length scale used to determine the highest flow frequency the particles are required to follow.
    2. The cut off stokes number is calculated using the frequency to determine the particle radius.
  17. 17Assumptions for determining flow frequency required.Energy supplied to small eddies is assumed equal to the dissipation rate of the large eddies.
    The large eddies are assumed to be dissipated within one integral length scale.
    Rate of energy supply to small eddies = e=u^3/L
  18. 18—

Information

Description
Masters Lasers and Optical Measurements Flashcards on GH Probes, tracer particles, created by Jack Moule on 12/02/2016.
Created by
Jack Moule
Views
0
Rating

More on Fluid Flow and Dynamics

Feedback

What is it about?

What should we add next?