Mind map
U3.5 Biometric Errors
Map content
U3.5 Biometric Errors
FMR and the FNMR are inversely related
- High tolerance threshold, lower imposter break in but higher denial of user access
- Lower threshold, increases imposter break in
- Setting the tolerance threshold involves a trade off between the 2 types of error
False Match Rate (FMR)
- Probability that a biometric measurement will be incorrectly considered a match for a different individuals biometric sample
- A function of the tolerance threshold
- Increase the tolerance threshold, lower the FMR
- Reduce the threshold increases the FMR
- FMR is the probability of a false match for a single comparison
False Acceptance Rate FAR is the probability an imposter is accepted by the system
- FAR is likely to be larger than the FMR
- An imposter can try impersonate several users increasing their chances of a break in
- FAR is likely to be larger than the FMR
False Non Match Rate FNMR
- probability that a valid user's biometric sample will incorrectly be considered a non-match for his/her reference template.
- Denial of access
- Also a function of the tolerance threshold
- Increase the tolerance threshold, the higher the FNMR
- if the minimum degree of similarity necessary for a match is set high, a valid user may have difficulties providing a sample of his biometric data that matches closely against his own reference template.
- if the tolerance threshold is reduced, the FNMR also decreases.
- probability of a false non-match for a single comparison
False Rejection Rate
- the probability that a valid user is rejected by the system
- false rejection rate is typically lower than the false non-match rate
Equal Error Rate ERR
- Rate at which both acceptance (FMR) and rejection (FNMR) errors are equal for any device.
- used as a standard measurement for biometric systems because it's a simple way to compare accuracy
- Rate at which both acceptance (FMR) and rejection (FNMR) errors are equal for any device.
Failure to enrol rate (FTER)
- users from the total population for whom the system is unable to generate repeatable templates
- Those unable to present the required biometric feature, unable to provide sufficiently distinctive biometric data, those unable to match reliably against their template following an enrolment attempt
- Will necessitate use of alternative authentication/identification
- Lowering the quality requirements for enrolment will decrease the failure-to-enrol rate but may compromise the overall securit
- Related to false match
- Higher the tolerance threshold, the higher the FTER
Failure to Capture Rate
- probability that the sensor system will fail to detect or correctly scan a biometric characteristic that has been presented correctly.
- sensors designed to work on a moving target at a distance area more difficult challenge.
- probability that the sensor system will fail to detect or correctly scan a biometric characteristic that has been presented correctly.