GoConqr has a new look! Let us know what you think.

Mind map

Non Destructive Techniques

turnitdownuk English

Map content

Non Destructive Techniques

  1. Reasons

    • Quality Control
      • Qualitative
        • Comparing measurements in one part of structure to another (irregularity)
      • Quantitative
        • Comparing on-site measurements of sample with lab measurements
    • Forensic: Failure analysis
    • Residual properties: resiliance
      • Lifetime prediction
      • Strengthening requirement
    • Properties and/or artefacts
      • Properties it was supposed to have
      • Compressive strength
      • Chemical composition
      • Whats under the surface
        • Corrosion
        • Internal cracking
        • Rebars/tendons
          • Size
          • Placing
        • Voids
        • Honeycombing (insiufficient compaction)
  2. Surveys

    • Systematic, grid based, time limited
    • Parallel visual/photo inspection
      • Cross correlate, 2 or more variables
  3. Types

    • Visual
      • Observing surface manifestations of sub-surface problems
        • Cracking
        • Staining
        • Pop-outs
        • Poor finish
      • Persistent external factors
        • Water: run off, pooling, blocked drainage
        • Damage caused by vegetation
    • Percussive/acoustic
      • Tapping with steel rod/small hammer
        • Listen to sound & Vibration
      • Rebound/schmidt hammer
        • Concrete properties: Strength
        • Qualitative - OK, cheap way to show poor areas
        • Quantiative - Poor, correlation between strength should not be done
      • Ultra Sonic Pulse Velocity
        • Strength
        • Related to stiffness E, and density, P
        • PUNDIT
          • Piezoelectric Transducers
        • Not that sensitive to speed of sound
          • Correlation tricky
        • Qualitative - Good, easy to establish areas of poor quality
        • Quantitative - Reliable if good calibration established
    • Electromagnetic/chemical/static
      • E-magnetic Covermeter
        • Rebar location, cover & Distance
        • Bar size & depth
        • Pros
          • Does what it says
        • Cons
          • Closesly spaced bars cause problems
          • Max cover depth = 60mm
          • Other steel causes problems
      • E-Chem: 1/2 cell potentiometer
        • Rebar corrosion
        • Measures electrochemical potential of steel at surface
          • Potential maps plotted
            • Close controus -> high current flow -> corrosion
        • Cons
          • Fiddly
          • Need saturated concrete
          • Need to break out to expose steel
        • Pros
          • Only way to give liklihood of corrosion
      • E-static: Capacitance
        • Experimental
        • Contrast in dielectric properties
          • Viewing distortion of electric field
        • Shows voids & rebars
  4. Last resorts

    • Sampling
      • Coring - samples for compression tests
      • Chemical analysis
    • Semi-destructive
      • Pull out bolts
        • Strength required to pull out

Information

Description
Mind Map on Non Destructive Techniques, created by turnitdownuk on 01/05/2016.
Created by
turnitdownuk
Views
1
Rating

Feedback

What is it about?

What do you think of the new look?

How do you like it?