Quiz
PDD Quiz V
Este quiz tem tipos de pergunta que abrem no player de sempre.
Perguntas do quiz (20)
1Which of the thermal insulation materials below are also good at sound absorption? 𝘾𝙝𝙚𝙘𝙠 𝙩𝙝𝙚 𝙩𝙝𝙧𝙚𝙚 𝙩𝙝𝙖𝙩 𝙖𝙥𝙥𝙡𝙮.
- ASlag wool
- BPolyisocyanurate
- CFiberglass
- DRock wool
- EExtruded polystyrene
2An architect is working on a historic renovation project. The building has brick veneer exterior walls, and the client wants recommendations on graffiti-resistant finish options for the existing walls. Which of the brick coatings below should be recommended to the client?
- AUrethane based coatings
- BMineral gum wax coating
- CAcrylic coatings
- DSilicone resin coating
- ESilicate based coatings
- FRTV silicone rubber coating
3"𝘈𝘯 𝘢𝘮𝘰𝘶𝘯𝘵 𝘵𝘩𝘢𝘵 𝘪𝘴 𝘴𝘱𝘦𝘤𝘪𝘧𝘪𝘦𝘥 𝘪𝘯 𝘵𝘩𝘦 𝘤𝘰𝘯𝘵𝘳𝘢𝘤𝘵 𝘥𝘰𝘤𝘶𝘮𝘦𝘯𝘵𝘴 𝘵𝘰 𝘤𝘰𝘷𝘦𝘳 𝘵𝘩𝘦 𝘤𝘰𝘴𝘵 𝘰𝘧 𝘢 𝘥𝘦𝘴𝘤𝘳𝘪𝘣𝘦𝘥 𝘪𝘵𝘦𝘮 𝘸𝘩𝘪𝘤𝘩 𝘪𝘴 𝘯𝘰𝘵 𝘧𝘶𝘭𝘭𝘺 𝘴𝘱𝘦𝘤𝘪𝘧𝘪𝘦𝘥 𝘪𝘯 𝘥𝘦𝘵𝘢𝘪𝘭 𝘢𝘯𝘥 𝘴𝘶𝘣𝘫𝘦𝘤𝘵 𝘵𝘰 𝘤𝘰𝘴𝘵 𝘢𝘥𝘫𝘶𝘴𝘵𝘮𝘦𝘯𝘵𝘴 𝘷𝘪𝘢 𝘤𝘩𝘢𝘯𝘨𝘦 𝘰𝘳𝘥𝘦𝘳𝘴 𝘥𝘶𝘳𝘪𝘯𝘨 𝘤𝘰𝘯𝘴𝘵𝘳𝘶𝘤𝘵𝘪𝘰𝘯 𝘢𝘥𝘮𝘪𝘯𝘪𝘴𝘵𝘳𝘢𝘵𝘪𝘰𝘯 𝘱𝘩𝘢𝘴𝘦"
Which one below describes this best?- ACash allowance
- BContingency allowance
- CUnit price
- DAlternate bid
4An architect reviews the masonry foundation wall and wood beam section details of a residential project. Which of the following detail is more likely to be observed during this review?
- AApplication of building felt, where direct contact between wood beam and masonry foundation wall exists.
- BFormwork details for masonry foundation walls.
- CDamp-proofing application at the foundation wall since subsoil conditions indicate the existence of hydrostatic pressure from the groundwater.
- DAdequate placement of construction joints (often called expansion joints) to allow movement to occur between a concrete slab and walls of the building.
5Which of the following criteria should be met for all foundations? 𝗖𝗵𝗲𝗰𝗸 𝘁𝗵𝗲 𝘁𝘄𝗼 𝘁𝗵𝗮𝘁 𝗮𝗽𝗽𝗹𝘆.
- APre-consolidation pressure
- BLimitations of settlement
- CAngular distortion
- DSoil strength
6Based on the moisture control performances, put the exterior wall assembly plan details below in the correct order. Drag & drop number "I" across the best assembly and number "III" across the worst option.

- AIII
- BII
- CI
7Which of the following type of air delivery system is the cheapest?
- ASingle-Duct Variable Air Volume Systems
- BSingle-Duct, Single-Zone Systems
- CAir Plenum System
- DDouble-Duct Systems
8Select prefabricated structural members below that use the same physics principle to increase the structural efficiency. 𝗖𝗵𝗲𝗰𝗸 𝘁𝗵𝗲 𝘁𝗵𝗿𝗲𝗲 𝘁𝗵𝗮𝘁 𝗮𝗽𝗽𝗹𝘆.
- ASolid Core Section Rectangular Steel Beam
- BHollow-core Concrete Slabs
- CI-section Beams
- DCastellated Beam
- ETubular Solid Core Section Steel Beam
9Which bolt type below was once used for primary applications but lost its popularity due to its strength performance compared to others?
- AA307
- BA325
- CA390
- DA490
10Which type of glass below is the most expensive?
- ATempered glass
- BHeat-soaked tempered glass
- CHeat-strengthened glass
- DAnnealed glass
11Drag and drop the given components of the masonry CMU backup detail across the highlighted letters shown below accordingly.

- ABond Beam
- BBoard Insulation
- CReinforced CMU block
- DBrick veneer
- EWeather barrier
- FTies to edge of slab
- GFire-stopping
12Which of the plan diagrams given below belongs to a half-surface hinge?

- A1
- B2
- C3
- D4
13Which of the following valve types is generally used to stop, start, and regulate flow within a pipe?
- AGlobe Valve
- BCheck Valve
- CGate Valve
- DBall Valve
14A boarding house with 11 permanent residents will be renovated to increase the occupant load to 15 residents. The house has two exits that the owner wants to keep functioning; however, the new design creates a dead-end corridor. What is the maximum allowable dead-end corridor length for this building?
https://codes.iccsafe.org/content/IBC2021P2- A20 feet
- B30 feet
- C40 feet
- D50 feet
15What force must be applied to a steel bar 1 in. square and 2 ft long to produce an elongation of 0.016 in? (Round the nearest tenth)
ΔL = PL/AE and Modulus of Elasticity of steel at 29,000 ksi- A19.3 kips
- B23.2 kips
- C24.01 kips
16A school building and an office building share the same lot, and they are located 25 feet away from each other. If both buildings are Type IA, what is the minimum required fire rating of exterior load-bearing walls for both structures?
https://codes.iccsafe.org/content/IBC2021P2- A1 Hour
- B2 Hours
- C2 1/2 Hours
- D3 Hours
17Bolts in a rigid connection are typically in... 𝗖𝗵𝗲𝗰𝗸 𝘁𝗵𝗲 𝘁𝘄𝗼 𝘁𝗵𝗮𝘁 𝗮𝗽𝗽𝗹𝘆.
- ATension
- BShear
- CBuckling
- DDeflection
18An architect of an office renovation project receives the cut sheets of the ceiling-mounted direct-light fixtures from the owner and wants to make sure that there is enough light on each work surface. Each worksurface gets a fixture directly above it with 720 CP each, and the underside of the finished ceiling is 10 feet AFF. What is the foot-candle on each work surface at 4 feet above the finished floor?
- A20 fc
- B40 fc
- C45 fc
- D180 fc
19Due to a number of revisions, the number of plumbing fixtures required for a school project increased significantly during the CD phase. The project architect is revising the plumbing walls to receive back-to-back fixtures rather than one side only. What is the minimum internal space required for the plumbing walls if there are fixtures on both sides?
- A8"
- B12"
- C16"
- D18"
20Which of the CMU wall scenario below would provide the highest STC rating at a typical exterior wall partition?
- APainted Hollow CMU
- BPainted & Grout-filled CMU
- CSand-filled CMU
- DRegular CMU
- ELoose-fill insulation filled CMU
Informações
- Descrição
- ARCH PDD Quiz sobre PDD Quiz V, criado por a a em 30-05-2024.
- Autor
- a a
- Idioma
- English
- Visualizações
- 18
- Etiquetas
- Avaliação
- Ainda sem avaliações Avalie este quiz
Mais sobre Construction Materials