  1. Determining Code Compliance

    • Construction Documents
    • Use group classification
    • Height and area - limitations based on use group
    • Construction Type - building materials used and fire resistance rating of the building elements
    • Siting - location of building on the site, including distance from lot lines and adjacent buildings
    • Fire performance
    • Interior environment and design - compliance with special use and occupancy requirements, means of egress, accessibility, and interior environment requirements
    • Exterior envelope - envelope requirements and energy conservation requirements
    • Structural Performance - structural compliance and building material requirements
    • Building service system
  2. CHECKING DRAWINGS

  3. Site Plan

    • Is there proper acccess to streets?
    • Are building separations adequate according to fire code resistance ratings?
  4. Plan and Sections

    • Verify that ceilling hieghts are permissible. Check heights of habitable spaces below grade
    • Verify that the height of the building is within allowable limits
    • Verify that the floor area of each floor is within permissible limits
    • Verify fire resistance of all building components
  5. Plans, Sections, Elevations

    • Verify that openings are protected where they are exposed to property lines, adjacent buildings, interior courts, or other openings in the same wall, above and below
  6. Plans and Sections: Egress

    • Confirm the number of occupants anticipated to occupy each floor of a building.
    • Verify the correct number, width, and arrangements of exits
    • Verify that distances to exits are within allowable limits
    • Verify that required exit door hardware is specified
    • Confirm the adequacy of aisles, corridors, and horizontal exits
    • Check that all stairways are properly located and enclosed, and that they provide a legal means of egress
  7. Plans

    • Verify that different occupancy types are separated by properly rated fire walls, etc
    • Verify that elevator, escalator, and vertical shaft enclosures are properly fire rated
  8. Specifications

    • Determine that finishes and trim meet requirements for proper classifications
    • Installation methods must meet code equirements for control of smoke emission and limitations of smoke toxicity
  9. Miscellaneous