Which one of the following is the correct drawing scale where a wall, 4m in length, measures 8cm on a drawing?
Answer
1:50
1:100
1:200
1:500
Question 8
Question
A drawing is produced to a scale of 1:50 showing a socket outlet installed 3.5cm from the corner of a room. Which one of the following is the actual distance from the corner in the room?
Answer
0.875m
1.75m
3.5m
7m
Question 9
Question
A circuit installed to supply a fire panel would be identified as:
Answer
power and heating
data communication
control circuit
alarm and emergency system
Question 10
Question
The type of trunking that can be used as a circuit protective conductor is:
Answer
mini
PVC dado
steel
plastic
Question 11
Question
The insulation material of mineral insulated metal sheathed cables is absorbent; therefore the terminations must be:
Answer
watertight
correctly identified
fitted with a gland
fitted with a shroud
Question 12
Question
Additional cable supports should be provided in trunking where:
Answer
segregation is required
there are long vertical runs
trunking is made of plastic
the walls are made of lightweight block
Question 13
Question
Band I and Band II circuits can be enclosed in the same enclosure, provided that:
Answer
the current rating of all circuits does not exceed 10A
they are twisted around each other along the trunking length
every cable or conductor is insulated for the highest voltage present
there are the same number of Band I and Band II circuits
Question 14
Question
Which one of the following is the type of conduit fixing shown?
Answer
Cleat
Clip
Crampet
Saddle
Question 15
Question
Which one of the following symbols represents the rating factor for thermal insulation?
Answer
Ci
Ca
Cf
Cg
Question 16
Question
Which one of the following is the value of voltage drop, per ampere, per metre, for a 10mm2 multi-core flat thermoplastic 70°C cable, intended to supply a single phase circuit?
Answer
44 mV/A/m
11 mV/A/m
4.4 mV/A/m
2.8 mV/A/m
Question 17
Question
Which one of the following is the maximum current carrying capacity for a single core 6mm2 70°C thermoplastic insulated non armoured cable, enclosed in conduit on a wall installed for a single phase circuit?
Answer
31A
32A
36A
41A
Question 18
Question
Which one of the following is the value of voltage drop, in millivolts per ampere per metre, for a 4mm2 multi core thermosetting non armoured cable, intended to supply a single phase circuit?
Answer
29 mV/A/m
18 mV/A/m
11 mV/A/m
7.3 mV/A/m
Question 19
Question
Which one of the following devices is suitable for an installation supplying an X-ray machine in a hospital?
Answer
BS 3036 rewireable fuse
BS EN 60898 Type D
BS EN 60898 Type C
BS EN 60898 Type B
Question 20
Question
Which one of the following devices will disconnect in the fastest time if a short circuit current of approximately 400A occurred on a circuit?
Answer
32A/30mA Type C RCBO
32A Type B circuit breaker
32A Type C circuit breaker
32A Type D circuit breaker
Question 21
Question
Which one of the following is the minimum conduit size suitable for a short straight run containing the following stranded cables:
• 4 x 1.5mm2
• 3 x 2.5mm2?
Answer
16mm
20mm
25mm
32mm
Question 22
Question
Which one of the following is the minimum conduit size suitable for a short straight run containing the following stranded cables:
• 8 x 1.5mm2
• 2 x 2.5mm2
• 2 x 4.0mm2?
Answer
16mm
20mm
25mm
32mm
Question 23
Question
Which one of the following is the conduit capacity factor to be used where a 25mm conduit has 2 bend in a 6m run?
Answer
111
182
333
600
Question 24
Question
The electrical system in which the connection to earth is by an earth electrode is:
Answer
TT
TN-S
TN-C
TN-C-S
Question 25
Question
Which one of the following earthing arrangements is shown in the diagram?