Building Codes Illustrated: Fire-Resistive Construction

Kara Biczykowski PA (Programming & Analysis) Building Codes Illustrated PA ARE 5.0 Englisch 41 Karten

Karten in diesem Stapel (41)

  1. 11) 2 basic methods for providing fire-resistive protection are: 2) passive protection works by: 3) active protection like sprinklers works by1) passive & active protection
    2) being built into the bldg structure & provides a barrier btwn the structure & fire
    3) responding to fire by activation of systems to contain/suppress fire & smoke to allow structure to remain intact for longer time period so occ. can escape
  2. 21) when code provisions otherwise req. active systems, they're not available to: 2) per ch2 "fire-resistance rating" is: 3) a bldg element is defined as:1) offset passive req.'s
    2) the period of time a bldg element, component or assembly maintains the ability to confine a fire, continues to perform a given structural function, both
    3) a fundamental component of bldg const. table 601, which may/may not be of fire-resistance rated const. & is constructed of mat.'s based on bldg type of const.
  3. 31a-b) summary of 2 purposes of fire-resistive const.:1a) 1st is protection of bldg structure
    w/ passive protection directly applied to structural members when used
    1b) 2nd is the separation of spaces to prevent the spread of fire or smoke w/in a bldg & spread of fire btwn bldgs
  4. 41) per 202 a fire area is defined as: 2) fire-resistance ratings are based on the performance of various mat.'s & const. assemblies under:1) the aggregate floor area enclosed & bounded by fire walls, exterior walls, fire-resistance-rated horiz. assemblies
    2) fire-test conditions as defined by ASTM Int. or Underwriters Labs typ. based on side of assembly fire would be likely to occur
  5. 51) 703.2.5 allows exterior bearing-wall rating req.'s to equal (___) b/c:1) those of nonbearing walls if all factors of fire separations & occ. considered b/c recognize it's main purpose is to prevent fire spread outside of bldg & no pt. in protecting the structure to a higher level than req.'d for enclosing the space
  6. 61) 703.2.3 assumed that tested assemblies are not (___) via definitions of ASTM E119 or UL 263 which refers to: 2) all designers should assume all assemblies to be (___) when determining (___) b/c:1) "restrained" - the ability of structural members to expand or contract under fire conditions
    2) "unrestrained" when determining fire-resistance req.'s b/c restrained assemblies are difficult to prove & outweigh the advg's gainedin reducing quantities of fire-protection mat.'s used
  7. 71) 703.3 allows designers to use several methods to demonstrate: 2) ^ one method uses ratings & code gives table 721 of prescriptive assemblies which gives the designer: 3) table 722 allows the designer to calc the fire-resistance of assemblies by:1) compliance w/ fire-resistive criteria
    2) a list of protection measures that can be applied to structural members, floor/roof const., walls to achieve necessary ratings
    3) combining various mat.'s
  8. 81) 703.3 allows engineering analysis based on ASTM E 119 or UL 263 to determine a projected fire resistance which means: 2) 703.3 also acknowledges testing measures of 104.11 which allows the:1) rq.'s use of consultant familiar w/ data to predict performance w/out time & expense of full scale fire test
    2) bldg official to approve alt ways of meeting the code when new technologies or unusual situations are encountered
  9. 91) 703.4 test criteria clarify that fire tests for rated assemblies may not include: 2) 703.5 defines (___) in terms of test criteria & characteristics that determine it can't be affected by:1) fire suppression, must pass w/out additional cooling from fire suppression water - reiterates req.'s for passive & active protection are to be considered separately
    2) noncombustibility - exposure to age, moisture, atmospheric combinations
  10. 101) 703.6 fire-resistance rated glazing when tested w/ ASTM E 119 or UL 263 & complying w/ fire barrier req.'s may be: 2) 703.7 fire walls/barriers/partitions, smoke barriers/partitions, or any other wall that req.'s protected openings shall have:1) used - glazing to have permanent label indicating fire-resistance in minutes
    2) a permanent sign/stencil marker in concealed spaces when accessible or not req.'d if can't be concealed -3" text, w/in 15ft of end of wall, 30ft max spacing
  11. 111) 704 req.'s the fire-resistance ratings of structural members & assemblies comply w/ the req.'s for: 2) 704.8 prohibits inclusion of service elements like pips/conduits into the: 3) 704.10 address the protection of structural members located on the:1) type of const. via ch6 & table 601
    2) fire production b/c it can conduct heat to structural member & potentially compromise time rating for fire-resistance
    3) exterior of a bldg, protection called out in table 601 - req.'d for exterior bearing walls, structural frame, or exterior walls based on fire separation distance
  12. 121) 704.2-3 req. individual structural members like columns or beams to be: 2) 704.6 allows attachment elements to structural members like reinforcing ties to: 3) ^ secondary members can be fire-protected by:1) fully protected on all sides for entire length if they are req.'d to have a fire-resistance rating (see code for det.)
    2) be closer to the surface of fire protection than thickness req.'d for main members
    3) horiz. assembly like a ceiling complying w/ 711
  13. 131) 704.2 req.'s full height of column to be: 2) 704.13 clarifies req.'s for:1) protected, even its connection to beams/girders or if extends through a rated ceiling
    2) sprayed fire-resistant mat.'s (SFRM) - typ. applied to steel members, rating dependent on thickness, cannot have cracks, delamination, or anything that lets a fire in
  14. 141) 704.9 req.'s (___) for elements w/ SFRM subject to damage extending a height of: 2) 704.4.1 allows studs & boundary elements like side of wndw that are integral to load-bearing wall of light-frame const. to have req.'d fire-resistance rating provided by:1) impact protection extending 5ft abv floor if SFRM can be damaged & knocked off element
    2) the membrane protection furnished for the load-bearing wall
  15. 151) 704.5 permits the encapsulation of an entire truss assembly w/: 2) 704.6 permits attachments to structural members like: 3) 704.7 allows stirrups & spiral reinforcement in a:1) fire-resistive mat.'s if assembly has been tested or on test calcs (this can also be construed to apply fire protection directly to individual truss members)
    2) lugs & brackets to w/in 1" of fire protection surface
    3) masonry or concrete structural member to project no more than 1/2" into the protection
  16. 161) 704.11 allows the bottom flanges of lintels & shelf angles to be:1) left unprotected when spanning 6'-4" or less or not part of primary structural frame which allows lintel over pair of 3ft doors
  17. 17EXTERIOR WALLS 1) 705 is the relationship to the property line of exterior walls & openings w/in & projections from the walls, it should be read in conjunction w/:1) w/ 1406 which governs the use of combustible mat.'s on exterior walls, 1021 for exterior egress balconies, & 1027 for exterior egress stairs
  18. 18PROJECTIONS 1) 705.2 governs the extent of allowable projections according to their relationship: 2) projections of walls Type I & II const. to be made of: 3) projection distances are based on:1) to the property line
    2) noncombustible const. vs projections of walls of other const. types can be any approved mat.
    3) fire separation distance per table 705.2
  19. 19PROJECTIONS 4) when the fire separation distance is btwn 2ft-3ft projection's min distance: 5) projections aren't allowed when: 6) when fire separation distance is greater than 30ft: 7) for distances from projection to fire separation of 3ft-30ft, projection may be:4) is 2ft
    5) fire separation distance is less than 2ft
    6) projections can only extend to w/in 20ft of fire separation line
    7) 2ft then +8" per foot
  20. 20COMBUSTIBLE PROJECTION PROTECTION 1) unrated projection if more than (___) from fire separation distance 2) combustible projections extending to w/in 5ft of lot line are to be: 3) R-3 & U occ. may have unrated Type V-B projections w/: 4) projections include elements like:1) 5ft
    2) min 1hr fire-resistance-rated const., Type IV fire-retardant-treated wood, see 1406.3
    3) greater than 5ft fire separation distance
    4) eave overhangs, cornices, balconies that extend beyond the exterior wall
  21. 21MULTI BLDGS ON SAME PROPERTY 1) 705.3 assumes an imaginary lines exists btwn bldgs, but not necessarily in the middle so long as: 2) 705.3's intent is to prevent the spread of fire by: 3) 705.5 req.'s that fire-resistance ratings for exterior walls area based on:1) it meets wall protection req.'s on distance assumed
    2) radiant heating or convection
    3) tables 601-2 to prevent spread of fire btwn properties
  22. 221) 705.5 explains when a bldg is >10ft from property line the fire exposure is assumed to be from: 2) ^ when a bldg is 10ft or less to property line, fire exposure assumed to be: 3) multi bldgs on same lot may be treated as portions of a single bldg if:1) the inside
    2) from either inside or outside the bldg b/c another bldg may be built on the lot line of adj property
    3) w/in the limits specified in ch5 for intended occ.
  23. 23FIRE RESISTANCE RATINGS 1) 705.6 the exterior wall is to extend to: 2) structural elements that brace the exterior wall & located outside of the plane of the wall must conform to tables: 3) 705.5 specifies exterior walls having a fire-separation distance >10ft be rated for: 4) ^exterior walls of 10ft or less be:1) the height req.'d by 705.11 (parapets)
    2) 601 for structural elements & 602 for wall ratings
    3) exposure to fires from the inside
    4) rated for exposure to fire from both sides
  24. 24OPENINGS 1) equation 7-2 in 705.8 is to determine # of openings allowable given the relationship of protected vs unprotected openings under the site & bldg conditionsAp/ap + Au/au
  25. 251) (other than group-H) exceptions to 705.8.1 allow unlimited unprotected openings in 1st floor of exterior walls if: 2) if openings in adj stories are w/in 5ft of ea. other. & lower one isn't protected by 1hr rating/> 705.8.5 req.'s:1) exterior walls face public st & have fire-separation distance of 15ft or face an unoccupied space 30ft wide w/ access to fire lane
    2) they're separated vert. min 3ft by a 1hr assembly rated for both sides fire exposure or by a horiz. flame barrier that extends 30" beyond exterior wall (req.'s don't apply to bldgs 3 stories/<, w/ sprinklers, open pkg garages)
  26. 26VERTICAL EXPOSURE 1) 705.8.6 req.'s that openings have approved: 2) opening protectives aren't req.'d where the roof has a min rating of: 3) bldgs on same lot & considered portions of one bldg aren't req.'d to:1) 3/4hr min fire-rated protectives if
    1a) >15ft vert. abv the roof of an adj structure on the same lot
    1b) w/in a horiz. fire distance of 15ft of adj structure
    2) 1hr & entire length of structural spans supporting roof have rating of 1hr
    3) comply w/ that section
  27. 27PARAPETS 1) the purpose of parapets is to: 2) typ parapets are to extend at least (___) abv the roof & be of const. type:1) impede the spread of fire from one bldg to another by providing a barrier to fire & radiant heat transfer if a fire breaks through a roof membrane
    2) 30" abv roof / same const. type as wall
  28. 28EXCEPTIONS TO PARAPETS 1) the wall satisfies the fire-separation distance criteria based on table 602 2) the bldg area doesn't exceed 1,000sf on any floor 3) the roof const. is entirely noncombustible or of at least 2hr fire-resistive const. 4) the roof framing is protected against fire exposure from the inside5) in resi occ. a fire barrier is provided by sheathing the underside of the roof framing, or is of noncombustible mat. for 4ft back from roof/wall intersection & entire bldg has a Class C or better roof covering
    6)705.8 allows the wall to have 25%/+ of its openings unprotected due to the bldg's location from a property line
  29. 29ROOF/CEILING FRAMING PARALLEL TO WALL 1) 1hr rated exterior wall 2) no openings are permitted w/in 5ft of fire-resistance-rated exterior walls in groups-R & M & 10ft separation req.'d for other occ.3) roof covering to be Class B min
    4) 1hr rated roof/ceiling framing parallel to exterior wall
    5) ^ for #4 - 4ft min for groups-R & M & 10ft for other occ.
  30. 30ROOF/CEILING FRAMING NOT PARALLEL TO WALL 1) 1hr rated exterior wall2) entire span of roof/ceiling framing must be of not less than 1hr fire-resistance-rated const.
  31. 31FIRE WALLS 1) 202 defines a fire wall as: 2) a fire wall can only perform function if:1) a fire-resistance-rated wall w/ purpose to restrict the spread of fire
    2) the wall extends cont. from the bldg fnd. to or through the roof w/ sufficient structural stability to withstand collapse if const. on either side of it collapses
  32. 32STRUCTURAL STABILITY 1) 706.2 req.'s that a fire wall have a structural configuration that allows: 2) ^walls constructed per (___) are deemed compliant 3) 706.3 req.'s fire walls to be constructed of (___) & of (___) in Type V:1) for structural collapse on either side while the wall stays in place for time req.'d by the fire-resistance rating
    2) NFPA 221, also using a double wall is easy way to comply
    3) noncombustible mat.'s / Type V can be of fire-protected combustible const.
  33. 33FIRE-RESISTANCE RATINGS 1) 706.4 bases the req.'d fire-resistance ratings of fire walls on: 2) 706.5 specifies fire walls are to be cont. horiz. from:1) occupancy, & for most the fire walls are req.'d to have 3hr ratings, but 2hr ratings ok in some Type II or V occ., always most stringent req.'s to be used
    2) exterior to exterior wall & extend min 18" beyond exterior surface of exterior wall to provide barrier to heat/flame propogation
  34. 341) 706.1 considers ea. portion of a bldg completely separated by one or more fire walls to be: 2) if fire wall is located on property line & considered a party wall, it's not allowed: 3) per NFPA 221 a double wall w/ min clearance btwn, ratings of ea. wall can:1) a separate bldg
    2) to have openings
    3) have ratings added together to = total needed for req.'d rating
  35. 351) a fire wall may terminate at the interior surface of exterior sheathing if: 2) rated protection may be provided by exterior wall const. w/ resistance rating: 3) 706.5 also allows fire wall to end at interior surface of noncombustible exterior sheathing if: 4) exterior wall intersections don't need fire protection when:1) rated protection forms a "T" & extends a horiz. distance of at least 4ft
    2) of min 1hr or noncombustible mat.'s
    3) the bldg on ea. side of fire wall is protected w/ auto sprinkler system
    4) intersections at fire walls form an angle =/> 180deg
  36. 361) opening protection criteria of 705.5 & 705.8 are to be applied to an exterior wall that forms: 2) 706.5.2 req.'s fire walls to extend to outer edge of horiz. projections when: (^3 exceptions to this req., see next card)1) an angle of <180deg w/ a fire wall intersection
    2) they are w/in 4ft of fire wall (balconies, roof overhangs, etc)
  37. 37EXCEPTIONS TO PROJECTIONS ADJ TO FIRE WALLS 1) the extension isn't req.'d when horiz. projecting elements have no concealed spaces &: 2) if noncombustible horiz. projections have concealed spaces:1) exterior wall behind & blw projection is min 1hr rated const. for distance not less than depth of projection on ea. side of fire wall, & openings in exterior wall must be rated 3/4hr
    2) a 1hr rated wall must extend through the concealed spaces & same as additional req.'s to #1 abv
  38. 38EXCEPTIONS TO PROJECTIONS ADJ TO FIRE WALLS 3) if combustible horiz. projections have concealed spaces, the fire wall must:3) extend through the concealed spaces to the outer edges of the projections, & additonal req.'s to # 1-2 previously
  39. 39VERTICAL CONTINUITY 1) 706.6 req.'s fire walls be continuous vert. from bldg: 2) roof const. is to be made of mat.'s: 3) presume fire projection of roof const. extends a min of 4ft on ea. side of fire wall when framing is: 4) ^assume the whole span when framing is:1) fnd. to a pt. at least 30" abv adj roofs
    2) that are noncombustible, fire-retardant treated wood, have fire-resistive mat.'s applied on inside to protect framing
    3) parallel to the wall
    4) perpendicular to fire wall
  40. 401) when a roof slope is 2:12 or more, the fire wall is to project abv: 2) exceptions to 30" extension abv roof when framing is parallel is: 3) exceptions to 30" extension abv roof when framing is perpendicular is:1) a pt. 30" abv a pt. measured 4ft laterally from the top of the wall
    2) not less than class-B roof, framing needs 1hr rating w/in 4ft of fire wall, framing to be supported by 1hr rated bearing walls/columns & beams, no openings w/in 4ft of fire wall, fire wall needs 2hr rating
    3) 1hr rating of entire span of framing, noncombustible roof sheathing/sim., no openings w/in 4ft of fire wall, not less than class-B roof
  41. 41—