Exams · US
ASCP MLS Laboratory operations: practice questions
Specimen acceptability, QC rules, proficiency testing, standard precautions, needlesticks and laboratory mathematics.
Updated 19 November 2026 for the current ASCP content guideline
Key facts
Verify patient identification and specimen acceptability before testing, and promptly communicate critical results according to laboratory policy.
Outline topic: Laboratory operations, quality, safety and mathematics
When quality control fails an established rejection rule, do not report affected patient results until the problem is corrected and acceptable control results are obtained.
Outline topic: Laboratory operations, quality, safety and mathematics
Treat proficiency testing samples like patient specimens and do not refer them to another laboratory for testing.
Outline topic: Laboratory operations, quality, safety and mathematics
Apply standard precautions to all patient specimens and wear PPE appropriate to the exposure risk.
Outline topic: Laboratory operations, quality, safety and mathematics
After a needlestick or mucous membrane splash, immediately wash or flush the exposed area, report the exposure, and seek prompt medical evaluation.
Outline topic: Laboratory operations, quality, safety and mathematics
Use C₁V₁ = C₂V₂ to calculate the volume of stock solution needed for a dilution.
Outline topic: Laboratory operations, quality, safety and mathematics
Sensitivity is true positives divided by all patients with disease, and specificity is true negatives divided by all patients without disease.
Outline topic: Laboratory operations, quality, safety and mathematics
Beer's law states that absorbance equals absorptivity multiplied by path length and analyte concentration.
Outline topic: Laboratory operations, quality, safety and mathematics
Chromatography separates substances by their differing distribution between a stationary phase and a mobile phase.
Outline topic: Laboratory operations, quality, safety and mathematics
Competency assessment verifies that personnel can perform assigned testing tasks according to established procedures.
Outline topic: Laboratory operations, quality, safety and mathematics
Use measurable learning objectives and evaluate whether learners can perform the required task.
Outline topic: Laboratory operations, quality, safety and mathematics
Sample questions
1. A specimen is collected in the wrong tube, making it unsuitable for the ordered test. Which phase of testing is affected?
- Analytical
- Postanalytical
- Proficiency testing
- Preanalytical
Answer: D. Preanalytical
Specimen collection occurs before analysis, so the error is preanalytical. Identifying the phase helps direct corrective action. Outline: Laboratory Operations, Quality Assessment/Troubleshooting.
- Analytical: Analytical refers to the testing phase.
- Postanalytical: Postanalytical refers to activities after testing.
- Proficiency testing: Proficiency testing is an external assessment of testing performance.
Source: Outline topic: Laboratory operations, quality, safety and mathematics
2. A laboratory calculates the mean of five control results: 98, 100, 101, 99, and 102 mg/dL. What is the mean?
- 99 mg/dL
- 99.5 mg/dL
- 100 mg/dL
- 101 mg/dL
Answer: C. 100 mg/dL
The mean is (98 + 100 + 101 + 99 + 102) / 5 = 100 mg/dL. A mean summarizes the central value of control measurements. Outline: Laboratory Operations, Laboratory Mathematics; Quality Control.
- 99 mg/dL: 99 mg/dL is one result, not the mean.
- 99.5 mg/dL: 99.5 mg/dL is below the calculated mean.
- 101 mg/dL: 101 mg/dL is one result, not the mean.
Source: Outline topic: Laboratory operations, quality, safety and mathematics
3. A specimen result exceeds an assay’s measuring range. The technologist mixes 1 part specimen with 4 parts diluent and retests it. The diluted result is 80 mg/dL. What is the original specimen concentration?
- 160 mg/dL
- 320 mg/dL
- 360 mg/dL
- 400 mg/dL
Answer: D. 400 mg/dL
One part specimen in five total parts is a 1:5 dilution, so 80 × 5 = 400 mg/dL. The dilution factor accounts for the reduction in concentration. Outline: Laboratory Operations, Laboratory Mathematics, Concentration, Volume, and Dilutions.
- 160 mg/dL: 160 mg/dL uses a factor of 2.
- 320 mg/dL: 320 mg/dL uses the four parts diluent as the factor.
- 360 mg/dL: 360 mg/dL uses a factor of 4.5.
Source: Outline topic: Laboratory operations, quality, safety and mathematics
4. A laboratory measures a control sample three times and obtains 98, 100, and 102 mg/dL. What is the mean control result?
- 98 mg/dL
- 100 mg/dL
- 101 mg/dL
- 102 mg/dL
Answer: B. 100 mg/dL
The mean is (98 + 100 + 102) ÷ 3 = 100 mg/dL. The mean summarizes the center of these control results.
- 98 mg/dL: 98 mg/dL is the lowest result, not the mean.
- 101 mg/dL: 101 mg/dL is higher than the calculated mean.
- 102 mg/dL: 102 mg/dL is the highest result, not the mean.
Source: Outline topic: Laboratory operations, quality, safety and mathematics
5. A laboratory evaluates a test in 100 patients with a confirmed disease. The test is positive in 90 and negative in 10. What is the test sensitivity?
- 10%
- 80%
- 90%
- 100%
Answer: C. 90%
Sensitivity is true positives divided by all patients with the disease: 90 ÷ 100 × 100 = 90%. It describes the proportion of affected patients detected by the test.
- 10%: 10% is the proportion of affected patients with negative results.
- 80%: 80% does not match the proportion of affected patients with positive results.
- 100%: 100% would require all affected patients to have positive results.
Source: Outline topic: Laboratory operations, quality, safety and mathematics