CAPILLARY ELECTROPHORESIS

Contenido del mapa
CAPILLARY ELECTROPHORESIS
ELECTROPHORESIS: HOW DOES IT WORK?
- differential migration of charged sp. in applied DC
- rate depends on CHARGED:SIZE RATIO
- migration rate ν= μeE
- μe = electrophoretic mobility α = ionic charge 1/α = frictional factors (size & shape, viscosity) E = applied field strength
electric field strength related to magnitude and length over which
migration rate : ν= μe x V/L
- V: voltage L: length of slab/capillary
Plate #: N= μeV/2D
- D: diffusion coefficient of solute
RESISTANCE (joule heating)
- V = I x R
- I = current R = resistance
- if use gel - produce heat. limit V applied for slab elect. ~500v
- Capillary typically 10-100μm ID and 30-100cm long (large surface:volume ratio = better cooling)
- P = I^2/R
- P = power dissipation = amt heat produced long capillary and small cross sectional area = high R
- P = I^2/R
- voltages we can use in cap.ele. typical applied voltage 10-25kV = E of 100-400 Vcm-1 typical N = 100,000 –200,000(HPLC 5,000 –20,000)
- V = I x R
ELECTROOSMOTIC FLOW
- high V applied - buffer-filled-Si cap. - bulk liq twds CATHODE
- pressure-induced
- electroosmotic flow
- EO Flow generally > electrophoretic migratn
- buffer = mob. phase
- EO flow = mob. phase pump
- all analytes are swept through column regarding the charged (CATION - NEUTRAL - ANION)
- electroosmotic flow velocity ν= μeoE
- μeo= electroosmotic mobility
- ion velocityν= (μe+ μeo)E
- migration rate tm= l/ (μe+ μeo)E = IL(μe+ μeo)V
- L= Length of capillary l = length to detector
- N = 16(tm/W)^2
CE HARDWARE
- Small vol- cap (4-5μL), injector/detector < 10nL (the result not concentrated)
- Cap: fused silica, external coating of polyimide (flexibility & durability)
- can reverse the polarity: anions elute first
- Sample Injection
- 5 -50 nL
- tips that can sample directly from cell/cell substructure
- Can be automated
- electrokinetic
- Voltage--> sample flow with EO flow + ion movement Injects larger amts of more mobile ions
- pressure
- electrokinetic
- Detectors (= HPLC)
- Optical
- Problem with low volumes = short pathlength = low absorbance or fluorescence
- modify cell to increase the pathlength
- Z-cell
- - path length 10 x the cap. diameter - increase path length -> decreases in peak efficiency = add spherical ball lenses btwn source-zcell-detector. - Increase sensitivity
- Bubble cell
- bubble formed near the end of the capillary
- Multireflection cell
- a reflective coating of silver is deposited on the end of the capillary
- Z-cell
- Adsorption & fluoro. (limits in conc terms, but equal or better in mass detection limits)
- Optical
- Indirect detection
- for compounds that don't have suitable chromophore/molar absorptivity - add ionic chromophore in the buffer, see any reduction in that signal
- Electrochemical
- conductivity & amperometry
- MS
- small volume of flow rate (1uL/min) allow to couple w MS
- common use of electrospray Ionisation (ESI)
- use volatile buffer
- CE/MS - use to detect proteins, DNA fragments n peptides. (large biomolecules)
APPLICATIONS OF CE
- Capillary Zone Electrophoresis
- small ions
- cation separations- wall untreated, analytes flow with EO flow twrds cathode
- Anions separation- wall treated, reversed EO flow twrds anode
- molecular sp.
- ions or non-ion (derivatization) - herbicides, persticides, proteins, aa. etc
- - buffer composition is constant - ionic components migrate into zones (complete resolved zone have buffer between zones)
- small ions
- Capillary Gel Electrophoresis
- performed in porous gel polymer matrix w a buffer mixture that fills the pores of the gel
- types of gel : polyacrylamide polymer, agarose, methyl cellulose etc.
- Capillary Isoelectric Focusing
- separate amphiprotic sp. (aa, proteins - have weak COOH and AMINE gp.)
- amphiprotic - sp in a soln is capable to donate or accept a proton.
- buffer mixture that continuously varies in pH along its length
- separate amphiprotic sp. (aa, proteins - have weak COOH and AMINE gp.)
- Capillary Zone Electrophoresis