  1. 1List four requirements of an air barrier in order for it to perform as it is intended:

    1. [blank_start]Continuity[blank_end]
    2. [blank_start]Structural[blank_end] [blank_start]Integrity[blank_end]
    3. [blank_start]Air[blank_end] [blank_start]impermeability[blank_end]
    4. [blank_start]Durability[blank_end]
    1. AContinuity
    2. BStructural
    3. CIntegrity
    4. DAir
    5. EImpermeability
    6. FDurability
  2. 2Because the component that performs the role of the [blank_start]air[blank_end] [blank_start]barrier[blank_end] changes from the wall to the window to the roof, [blank_start]continuity[blank_end] means that all these [blank_start]assemblies[blank_end] must be connected together so as to ensure that there is no break in the [blank_start]airtightness[blank_end] of the [blank_start]envelope[blank_end].
    1. Aair
    2. Bbarrier
    3. Ccontinuity
    4. Dairtightness
    5. Eenvelope
    6. FAVB
    7. Gstructural
    8. Hintegrity
    9. Iassemblies
  3. 3Select the answers that best describe the following:

    An air barrier must be...



    1. Acapable of resisting the imposed load or supported by one that can
    2. Bcapable of moving outside of the structural elements
    3. Ccapable of resisting wind load that is acting either as a pressure or suction
    4. Dcapable of resisting wind from the outside
    5. Ecapable of moving with the flow of air
    6. Fcapable of resisting the pressurization resulting from exhaust or stack effect
    7. Gcapable of holding the structural integrity of a building together
  4. 4What is the primary cause of building failures in Canada?

    [blank_start]Air leakage[blank_end]
    1. Aexcessive air leakage
  5. 5When should you consider air leakage as requiring special attention?

    1. [blank_start]During the design stage[blank_end]
    2. [blank_start]During construction[blank_end]
    1. ADuring the design stage
    2. BDuring construction
  6. 6What approach initialized a change in construction practices in Canada?

    [blank_start]Insulating on the outside[blank_end]
    1. AInsulating on the outside
  7. 7Name the three types of roofing systems:

    1. [blank_start]Conventional Roof System[blank_end] ([blank_start]CRS[blank_end])
    2. [blank_start]Protected Membrane Roof System[blank_end] ([blank_start]PMRS[blank_end])
    3. [blank_start]Modified Roof System[blank_end] ([blank_start]MRS[blank_end])
    1. AConventional Roof System
    2. BCRS
    3. CProtected Membrane Roof System
    4. DPMRS
    5. EModified Roof System
    6. FMRS
  8. 8The roofing membrane in a conventional roof system is located:
    1. Abelow the thermal barrier
    2. Bbetween the thermal barrier
    3. Con top of the thermal barrier
    4. Dnear the thermal barrier
    5. Enear the drainage plane
    6. Fbehind the insulation
  9. 9In a protected membrane roof system, the thermal barrier:
    1. Ais on top of the roofing membrane
    2. Bis attached to the structure
    3. Chas holes in it to allow for ventilation
    4. Dis below the drainage plane
  10. 10In a modified roof system, the roofing membrane is [blank_start]between[blank_end] the [blank_start]thermal barriers[blank_end]
    1. Abetween
    2. Bthermal barriers