Flashcards
AED Use in Special Situations
Cards in this deck (8)
- 1During AED use, name 4 special situations that may require the operator to take extra care in placing the AED electrode pads-Hairy chest
-Water
-Implanted pacemaker
-Transdermal medication patches - 2WHO has implanted defibrillators/pacemakers and WHAT do they do for the patient?Patients at high risk for sudden cardiac arrest
They automatically deliver shocks directly to heart muscle if a life threatening arrhythmia is detected. - 3How can you physically identify that a patient has an implanted defibrillator/pacemakerThey create a hard lump beneath the skin of the upper chest or abdomen
The lump ranges in size from the size of a silver dollar to half the size of a deck of cards along with an overlying scar - 4How does the presence of an implanted defibrillator affect the attachment and use of an AED?The presence of an implantable defibrillator is NOT A CONTRAINDICATION to attaching and using an AED
-Avoid placing the AED electrode pads directly over the device tho (they can interfere) - 5Occasionally the analysis and shock cycles will conflict. If the implantable defibrillator/pacemaker is automatically delivering shocks to the patient (muscle contraction like AED shock) what should you do for use of AED?Allow 30 to 60 seconds for the implantable defibrillator/pacemaker to complete the treatment cycle before delivering a shock from the AED
- 6What are the 2 main steps when using an AED and you identify an implanted defibrillator/pacemaker?-> if possible place the AED electrode pads to either side and not directly on top of the implantable device
-> follow the normal steps for operating an AED - 7How does the presence of a transdermal medication patch affect the attachment of an AED electrode pads? Explain.DO NOT PLACE AED ELECTRODES ON TOP OF MEDICATION PATCH
The med. patch may block the transfer of energy from the electrode pad to the heart or cause small burns to the skin - 8How do you prevent the complications that arise with transdermal medication patch and AED electrode pads?.to prevent complications, remove the patch and wipe area clean before attaching AED electrode pad.
Try to minimize interruptions in chest compressions and DO NOT delay shock delivery
Information
- Description
- Masters Degree ACLS Course (VF Treated with CPR & AED Case) Flashcards on AED Use in Special Situations, created by Carrie Odeneal on 06/05/2015.
- Created by
- Carrie Odeneal · May 2015
- Updated
- Apr 6, 2018
- Views
- 2
- Rating