Ajude a dar forma ao GoConqr. O que a gente deve adicionar?

Flashcards

Section B

samsden Brain imaging msc Inglês 25 flashcards

Flashcards do conjunto (25)

  1. 1Why is statistical analysis of fMRI data challenging?-massive amount of data
    -signal is weak and noisy
    -doesn't directly measure neural activity
  2. 2What are the fundamentals of data analysis?-Plot the data on same scale for comparison (& remove outliers),
    -Data averaging, to enhance signal-noise
    -Detrend the data, if there is a slow varying component of the data
    -Correlation
  3. 3Explain slice timingAs all brain slices aren't collected at the same time, interpolating will synchronize slice. (fit curve and put data at correct time points)
  4. 4What two techniques help one tell which side of the image is left?1) place a pill behind the left/right ear of participant and log it
    2) conduct a simple motor task with right or left hand
  5. 5The rigid body assumption assumes the spatial difference between 2 brain volume data sets can be a accounted for by a rotation and translation. What does the rotation matrix look like in v_1=Rv_2+TR= ( cos(theta) -sin(theta)
    sin(theta) cos(theta) )
  6. 6What is the minimized error function for re-alignment? How is realignment performed in the framework of multiple sessions?s=f(correlated brain volume -
    reference brain volume)
    The first volume of each session is re-aligned with the first volume of the first session.
  7. 7Normalizing brain volume to the SPM EPI (echo planar imaging) template allows for inter subject comparison. How is the transformation performed to sets of data?The mean volume of each re-aligned data set is first normalized to the SPM template. The transformation is then applied to all re-aligned volumes within the set.
  8. 8What is the name of the translation performed in normalization ( a b| c d ), which allows rotation, translation, sheer, stretching, and shrinking?Affine transformation
  9. 9As a result of hardware a preprocessing the fMRI images are spatially noisy. What kernel performs spatial smoothing of the data?A gaussian kernel of a specified width (full idth at half maximum) for example FWHM=2.35sd
  10. 10What does the scaling parameter, a, represent?Strength of BOLD response to stimulation at corresponding voxel location. It reflects 'brain activity' in response to a stimulus.
  11. 11When is a t statistic useful over other statistical tests?-Small sample size
    -Unknown population standard deviation
  12. 12T tests can help determine model parameters. They can look at individual, differential, and interaction effects. What is the t-test formula for interaction?t=(a_2 - a_1)-(a_4 - a_3)/
    se( (a_2 - a_1)-(a_4 - a_3))
  13. 13How can one modify the design matrix to take into account that people's reaction times are different for the same stimulus?Add the derivative of the model as a column in the design matrix.
  14. 14Neighboring voxels are not independent due to continuity in the data. What correction is necessary for a multiple dependent comparisons?Gaussian random field theory
  15. 15What are 3 possible reasons for different fitted parameters for different subjects?-variation due to measurement noise
    -subject variation
    -between subject variation
  16. 16What are key equations of summary statistics in mixed effect analysis? What assumption is made.Y=X1(X2 B2+E2)+E1=X1 X2 B2+X1 E2+E1
    =X1 X2 B2 +n2,
    Cov(n2)=X1 C2 X1^t+C1 where
    C1=Cov(E1) and C2=Cov(E2).
    So X1 C2 X1^t ∝ C1, is an assumption.
  17. 17What steps do you perform mixed effect analysis with, using SPM? (steps 1 & 2)1) Do 1st level analysis for each participant & obtain estimated model parameters (B)
    2) Select appropriate contrast vector and apply to each participant
  18. 18What steps do you perform mixed effect analysis with, using SPM? (steps 3, 4, & 5)3) Model estimated model parameter from 1st level analysis at 2nd level:
    Bi^=[1]B^+ei
    4) Enter the same contrast image in each subject into the 2nd level
    5) Do a one sample t-test
  19. 19What are some issues with all-in-one, mixed effect analysis?- parameter optimization is iterative and computationally expensive
    -huge design matrix
    -cannot look into individual subject results
    -additional subjects means total re-analysis
  20. 20Why is a long box car design not ideal?-human factor: subjects can't concentrate on a task for that long
    -high pass filter is usually needed to remove low frequency noise
  21. 21Why is a dense box car design not ideal?With hrf the baseline is never established.
  22. 22In event relate designs, what greatly increases efficiency?Randomisation, and more stimuli. This allows a baseline to be established, as well as the researcher gets more data.
  23. 23Can null events improve design efficiency? If so, give an example.Yes.
    Event related design variance
  24. 24What are the stages in performing selective averaging in order to estimate a haemodynamic response function?1) include null events randomly spaced with events of interest
    2) Calculate mean time series for all events and non-events
    3) estimated hrf=av event - av nonevent
  25. 25What are some basis functions that can approximate the an unknown hemodynamic impulse response function?-Fourier basis functions (sines and cosines)
    -gamma functions

Informações

Descrição
msc Brain imaging FlashCards sobre Section B, criado por samsden em 25-05-2016.
Criado por
samsden
Visualizações
2
Avaliação

Mais sobre fMRI and Functional Neuroimaging

Fale Conosco

Sobre o que é sua mensagem?

O que a gente deve adicionar?