  1. RADIATION : The energy radiated or transmitted in the form of rays, waves, or particles. A stream of particles or electromagnetic waves that is emitted by the atoms and molecules of a radioactive substance as a result of nuclear decay.

  2. NUCLEAR REACTIONS

    • Spontaneous disintegration
      • nothing initiates; nothing stops energy range: 15 keV < x < 20 MeV
    • Artificial mutation
      • interaction of two nuclei producing other nuclei
    • Nuclear fission
      • heaviest nuclei split into 2 or more lighter nuclei
    • Nuclear fusion
      • light nuclei combined to form heavier nuclei
  3. Why is Radiation a Useful Analytical Tool?

    • characterisedby the type and energy of the radiation they emit
    • Easily detected and quantified
    • Generally have low background
    • Measure concentrations as low as 10^-14 M
  4. Main Radioanalytical Methods

    • Measuring Naturally Occuring Radiation
      • e.g. Measuring radon in homes Dating artifacts or sediments
    • Tracer Methods
      • Radioactivity is physically introduced to the sample by adding a measured amt of radioactive sp. (tracer) most important - ISOTOPE DILUTION METHOD (a weighed quantity of radioactive tagged analyte having a known activity is added to a measured amt of the sample. mixed- a fraction of the component of interest is isolated & purified.
    • Activation Analysis
  5. Language

    • Units
      • Define these as measure of the activityof a substance In general activities in the range of 0.1 –20 kBq(3-500 nCi) are sufficient for analytical applications.
      • Becquerel (Bq)= 1 decay per second
      • Curie (Ci)= the activity of 1 g of 226Ra = 3.70 x 10^10Bq
      • Electron Volt = 1 MeV = 1.6 ×10–13J per particle≈105 MJ/mol
    • Half Life
      • Time required for one half of the number of radioactive atoms in a sample to undergo decay
    • Positron ẞ+
      • - forms when the number of protons in nucleus reduced by 1 - has mass of electron- transitory existence –reacts with electron to form γrays
    • Negatron ẞ-
      • high energy electron that is formed when a neutron is converted to a proton
    • Electron capture
      • electron is captured by the nucleus and combines with proton to form a neutron. Neutrino is emitted.
    • Decay Processes
      • α decay
        • in isotopes mass >150 particles either monoenergetic or distributed among few discrete energies lose energy as result collisions as pass through matter low penetrating power easily measured
      • β decay
        • - atomic number changes but mass number does not - lose energy by interacting with electrons in orbitals - particles have continuos spectrum of energies  - penetrating power greater because smaller particles
        • negatron formation
        • positron formation
        • electron capture
      • γ-ray emission - (produced by nuclear relaxation)
        • - occurs when nucleus left in excited state by α or β emission process  - returns to ground state in one or more quantized steps with release of monoenergetic γ-rays  - X-rays result of electronic relations                          = γ-ray wavelength generally 1/100thX-ray            = γ-rays produced by nuclear relaxations - γ-ray emission spectrum characteristic for each nucleus highly energetic = highly penetrating
        • Lose E via:
          • photoelectric effect (γ-ray photon disappears)
            • electrons released on exposure of (metal) surface by overcoming electron binding energy (low E)
          • Compton effect (photon recoils, repeat the rxn)
            • electrons ejected from atoms but with only part of the photon’s energy; photon recoils with reduced energy to act again (Relatively energetic)
          • pair production (creates positron & electron)
            • photon totally absorbed in creating a positron and an electron in the field near the nucleus (High Energy)
  6. Measuring Radioactivity

    • Spontaneous disintegration
      • Stability of nucleus
        • - complicated function of atomic number and atomic mass - trend for stable nuclei to have more neutrons than protons
      • Probability
        • - cannot tell when an individual atom will disintegrate but the average behaviour of a large number of nuclei can be predicted precisely
      • Characteristic spectra
        • each type of nucleus has a characteristic pattern of disintegration i.e. emit specific kinds of radiation with individual energy patterns
      • Disintegration rates
        • rates are always first order (straight line - easy to predict)
    • Radioactive decay rates
      • –dN/dt = λN
        • N - # radioactive nuclei t- time  λ - decay constant
        • If we look at an interval from t0 to t then: –( ln N –ln N0) = λdt ln (N / N0) = –λt N = N0e –λt
      • Activity (A) : A = A0e –λt (A: disintegration rate)
        • A = c N c = detection coefficient of detector This means:–dA/dt = –dN/dt and hence also  ln (A / A0) = –λt
      • Half Life t(1/2) = (0.693/ λ)
        • half life = time taken for N = N0/2
    • Radioactive equilibrium
      • - Steady state in which all radioactive ‘child’ products are decaying at the same rate as they are being formed by decay of their radioactive ‘parents’. - useful for determining the half life of a very long-lived radioactive element such as uranium.
      • λ1N1= λ2N2
  7. DETECTORS

    • depends on the ionization of matter caused by radioactivity
    • Photographic emulsions
      • Photoelectrons knocked off halide ions cause reduction of Ag+ Ag atom then act as a focus for further reduction Produce black spot on the photographic film
    • Cloud chambers
      • Air supersaturated with water (or other vapour like ethanol) Produces ‘tracks’ along the path of radiation Droplets condense around ions / electrons produced by radiation.
    • Gas-filled detectors
      • QUANTITATIVE
      • Inert gas filled - ionized (Ar+) and electron = (ion pairs)
      • e- move towards anode and ions move twrds cathode. - e- movement - charged electric current twrds the meter - reading
      • detector behaviour depends on the voltage applied
        • too low, the ion pairs simply recombine and are not detected. high enough, collisions between accelerated electrons and gas molecules cause secondary ion pair production, i.e. amplification.
        • Ionisation chamber ==> (# electrons reach anode = total # produced by radiation)
          • e.g. smoke detector
        • Proportional ==> (# electrons increases with voltage because increase ions)
        • Geiger ==> (enormous amplification but current limited by tube design)
          • * most sensitive
      • 'dead time' = Ionizations in the chamber take a finite time to dissipate, during which no further response can occur.
    • Scintillation counters
      • QUANTITATIVE
      • Based on radiation-induced luminescence
        • i.e. electronic excitation rather than ionization
      • Excited atom relaxes, emitting a flash of light (at longer wavelength than γ)
      • Structure
        • - scintillation crystal - doped with organic substance (usually w benzene ring) to absorb the gamma radiation - use crystal (more dense) and gamma radiation tend to react w that
    • Semiconductor detectors
      • QUANTITATIVE Lithium-drifted silicon detectors Si(Li) Lithium-drifted germanium detectors Ge(Li)
      • Diode-like devices based on lithium-doped germanium and silicon
      • gamma / X-rays
        • gamma rays react with LI- pop the electron from Li. the electron migrate to form the actual compound
      • structure
        • Li vapour-deposited onto p-type Ge/Si crystal and heated Li atoms diffuse into the crystal where they act like ionizable atoms in a gas-filled detector
      • Better than a proportional gas-filled counter because there is no secondary ionization so dead times are small.
      • disadvantage- must be cooled by liquid N2
        • - prevent Li diffusion out of the Ge/Si - decrease noise to an acceptable level  - modern examples only need cooling when in use
        • not portable
      • Ge used instead of Si when wavelength < 0.3 Angstroms must be cooled at all times
    • Counting Corrections
      • Background radiation
        • cosmic effects surroundings laboratory contamination
      • Counting geometry
        • radiation is emitted in all directions orientation and distance of counter is important
      • Back-scattering
        • - radiation directed away from the counter can be reflected back into it by objects behind sample &nbsp;- use reproducible sample holders made of absorbing material
      • Self-scattering
        • - radiation is deflected and absorbed by the sample itself so counts = f (sample thickness) - make samples as thin and as reproducible as possible
      • Decay
        • samples with short half-lives decay during counting need to correct if counting period &gt; 10% of t½
      • Dead-time corrections
        • - all detectors take finite time to recover after sensing the arrival of a radioactive particle - other particles arriving in this time interval are not detected- also called ‘co-incidence corrections’
        • Geiger tube50 –200 μs Scintillation0.25 μs Know dead time R* = R/(1-Rτ)
          • R* = true count rate R = obs count rate τ = dead time
      • Determining Dead Time
  8. RADIOANALYTICAL METHODS

    • Chemical tagging
      • Introduce a ‘hot’ (radioactively visible) isotope into a process containing a ‘cold’ isotope, to follow the latter
      • Analytical procedures
        • Used to determine % efficiencies (errors from co-ppt, occlusion, etc. are thus eliminated)
      • Industrial processes
        • Trace disposed waste / transport of pollutants
      • Biological processes
        • Trace biochemical pathways e.g. in citric acid cycle
      • Determining solubilities
        • Can measure the activity of a saturated solution without evaporation or weighing.
      • Advantages
        • -Selectivity (Independent of quantitative isolation) -Simplicity of equipment
      • Disadvantages
        • Exchangeability
          • If isotope occurs in a compound it can sometimes ‘exchange’ e.g. tritium+ and H+
        • Differences due to atomic mass
          • Isotopes do not always mimic each other exactly e.g. diffusion of deuterium and tritium is much slower than that of hydrogen
    • Isotope Dilution
      • Rm= activity of isolated mass wm= weight of isolated mass wx= weight of unknown wt= weight of tracer Rt= count of tracer
      • Specific activity of a radionuclide is reduced when it is mixed with its stable counterpart.
      • The extent of reduction in activity provides a measure of the amount of stable isotope with which the radio-isotope is mixed.
    • Activation Analysis
      • making sample radioactive by irradiating with neutrons/charged particles
      • Sources : reactors radionuclides particle accelerators
      • thermal neutrons
        • Energetic neutron passed through moderating material to dissipate energy and create
      • fast neutrons
        • For light elements e.g. F, O, N use fast neutrons(14 eV)
      • detection limit
        • Detection limits for many elements are &lt; 1 μg; for some elements as low as picogram level
      • Neutron captured by analyte nucleus causing excited state and γray emmission
      • Capture cross-sections
        • measures of probability that interaction will occur. The values are obtained from tables. Units are in barns (1 b = 10-24cm2)
      • Number of nuclei that are produced during irradiation (N* = N φσS)
        • S = saturation factor
      • activity is directly proportional to number of radionuclides
      • Advantages
        • high sensitivity, minimal sample preparation, easy to calibrate, often non-destructive,
      • Disadvantages
        • Expensive equipment and special facilities required OHS considerations when dealing with radionuclides Time for analysis when using long-lived radionuclides
  9. OHS and Radioanalytical Chemistry

    • Dosimetry
      • Special steps need to be taken when working with radioactive sources e.g. personal radiation monitors for monitoring dose
      • Thermoluminescent dosemeter (TLD)
        • Electrons in the crystal structure of the TLD material excited to higher energy levels as a result of irradiation and are trapped in the crystal structure. Response of TLD dependent on the energy and type of radiation
    • Units
      • Different units are used because the effects depend on the type of radiation, type of material and other circumstances
      • Roentgen (ion dose)
        • unit of exposure defined in terms of amount of charge generated when radiation is stopped in air Now, 1 R = 2.58 ×10-4Ci / kg For a standard human, I R ≈10-5J
      • RAD (energy dose)
        • unit of absorbed dose defined as amount of radiation that liberates 10-2J/kg of irradiated material independent of the type of radiation but function of material
      • Gray (Gy)
        • SI unit for energy dose 1 Gy = 1 J/kg = 100 rad
      • REM (equivalent dose)
        • measure of biological damage, defined in terms of a factor called the Relative Biological Effect(RBE)which takes account of different circumstances 1 REM = dose in RADS ×RBE RBE= dose of γrays that produces the same effect as 1 RAD of the particular type of radiation (so standardising REM)
        • RBE
      • Sievert (Sv)
        • dose in Gy multiplied by an effectiveness factor 1 mGy dose of αrays = 20 mSv of equivalent dose 1 mGy dose of βrays = 1 mSv equivalent dose In most cases the effectiveness factor is unity and the dose in grays is equal to the dose in sieverts

Imagens e arquivos do mapa

  • RADIOCHEMISTRY
  • RADIOCHEMISTRY
  • RADIOCHEMISTRY
  • RADIOCHEMISTRY
  • RADIOCHEMISTRY
  • RADIOCHEMISTRY

Informações

Descrição
undergraduate degree analytical chemistry Mapa Mental sobre RADIOCHEMISTRY, criado por chaz_id89 em 05-11-2013.
Criado por
chaz_id89
Visualizações
74
Avaliação

Fale Conosco

Sobre o que é sua mensagem?

O que você acha do novo visual?

Você gostou?