Unit 3 - Image Quality

RadTech Fairy Image Evaluation ARRT Englisch 5,0Durchschnittliche Bewertung 5,0 von 5 (1 Bewertung) 48 Karten

Unit 3 - Image Quality

Karten in diesem Stapel (48)

  1. 1mAs influencesdensity
    brightness
    shades of black
  2. 2kVp influencescontrast
    shades of gray
  3. 3higher kVp will producemore contrast and shades of gray
  4. 4short-scale contrasthigh contrast
    few shades of gray
    low kVp
    _____________
    finger, toe, femur, humerus, elbow, etc...
  5. 5long-scale contrastlow contrast
    many shades of gray
    high kVp
    _________________
    abdomen, chest, fluoroscopy, etc....
  6. 6Densitythe quantity of photons reaching the IR
  7. 7—Insufficient Density
    image appears too bright
    (too many x-ray photons)
    Insufficient Density image appears too bright (too many x-ray photons)
  8. 8—Excessive Density
    image appears too dark
    (too few x-ray photons)
    Excessive Density image appears too dark (too few x-ray photons)
  9. 9Spatial ResolutionDetail
    Sharpness
  10. 10Which factors contribute to SIZE distortion?Far SID
    Short OID
  11. 11Which factors contribute to SHAPE distortion?tube angle
    anatomical centering
  12. 12What are 2 forms of distortion?distortion of size (magnification, foreshortening, elongation, etc.)
    distortion of shape (centering, tube angle, tilted IR, etc.)
  13. 13Window Levelchanges brightness
  14. 14if an image is too dark, you can increase brightness by ________ window levelincreasing
  15. 15if an image is too light, you can decrease brightness by _________ window leveldecreasing
  16. 16ContrastCombined result of the quality of the x-ray beam, quality of radiation, quality of the IR, and computer processing and display
  17. 17TRUE OR FALSE? elements of high anatomic numbers absorb radiation doseTRUE:
    Ca+ in bones has a high atomic number, therefore it absorbs radiation and appears white on a radiograph
  18. 18Subject Contrastradiation will be absorbed differently throughout the body for regions of high atomic numbers vs. regions of low atomic numbers
  19. 19—
  20. 20—
  21. 21A radiographic image that has a greater resolution minimizes the amount of __________ of the anatomic structural linesunsharpness
  22. 22Good diagnostic quality is achieved by _______ _________ and by _______ _____ .maximizing resolution
    minimize distortion
  23. 23TRUE OR FALSE? increasing the bit depth of digital pixels, will increase the shades of gray within each pixelTRUE
  24. 24TRUE OR FALSE? increasing the number of pixels in a matrix will decrease the image qualityFALSE
    having more pixels increases potential for better contrast
  25. 25TRUE OR FALSE? With DR, you can't overexpose the patient and have a good radiograph.FALSE.
    Even if your image comes out overexposed you can postprocess the image by changing your window level and still create an acceptable radiograph without re-exposing the patient.
  26. 26The exposure indicator provides a numeric value indicating the level of radiation exposure to the __________digital image receptor.
  27. 27Window level adjusts ________brightness
  28. 28Window width adjusts ________contrast
  29. 29wide window width will produce _________ and a narrow window width will produce ________low contrast
    high contrast
  30. 30Pixel Pitchdistance between two pixels where they come together in the middlePixel Pitch
  31. 31Visibility of Recorded Details includes:-brightness
    -density
    -contrast
  32. 32Sharpness of Recorded Details includes:- spatial resolution
    - distortion
  33. 33Brightnessamount of luminance
  34. 34Densityamount of blackness
    - controlled by mAs
  35. 35Contrastquality of radiation absorption within the body
    - controlled by kVp
  36. 36Low-Subject Contrast-similar tissue types
    - similar shades of gray
    *ABDOMEN*
  37. 37High-Subject Contrast- varying tissue types
    - varying shades of black -> gray -> white
    *CHEST*
  38. 38High contrast, with low kVp and few shades of gray describes _____ _____ contrastShort - Scale
  39. 39Low contrast, with high kVp and many shades of gray describes _____ ______ contrastLong - Scale
  40. 40Size Distortion is characterized by ______ and _______Magnification
    OID/SID
  41. 41Shape Distortion is characterized by _______ _______ and ______elongation
    foreshortening
    tube angle
    patient positioning
  42. 42Using a grid will ________ contrast and ________ density. Therefore, you should _______ _____ when using a gridincrease
    decrease
    increase mAs
  43. 43What are 3 examples of decreasing exposure time?1. decreasing SID increases speed
    2. increase mA, decrease time
    3. increase kVp
  44. 44The area of the anode surface which receives the beam of electroms from the cathode is known as _____ _____FOCAL SPOT
  45. 45As focal spot size decreases, _________ decreases, and ________ increasesunsharpness
    recorded detail
  46. 46Bit Depthhow the exit radiation is recorded
    controls the pixel brightness
  47. 47Matrixrows and columns of the image
  48. 48Pixeleach individual box in a matrix