Ajude a dar forma ao GoConqr. O que a gente deve adicionar?

Mapa mental

Rules & Regulations Radiology

Zainab Patel Radiology Inglês

Mind map on rules & regulations radiology: IRR 2017, IRMER 2018, FGDP grading and pregnancy

Mind map: Rules & regulations radiology

Conteúdo do mapa

Rules & Regulations Radiology

  1. IRR 2017

    • Protects staff & members of the public who are NOT patients
    • Aim
      • Ensure that ionising radiation is ALARP
    • They enforce:
      • RPA
        • Can be out of practice
        • Radiation expert who advises on all aspects of radiation safety and equipment, helps practices comply to IRR
      • RPS
        • In practice
    • AKA
      • Ionising Radiation regulations
    • Used to be 1999
    • New regulations
      • Graded approach based on perceived risk associated with IRR
      • If there is a medium risk then you need to register with HSE if you are the employer in the practice
        • Online system
        • Old regulations didn't make it that deep
        • HSE = health, safety & environment
      • HSE decided that lead shielding of controlled area unacceptably expensive with little practical benefit.
  2. IRMER 2018

    • AKA
      • Ionising radiation (medical exposure) regulations
      • Used to be 2000
    • Protects patients
    • They enforce:
      • Referrer
        • Initiates request
        • Dentist
      • Practitioner
        • checks request justified and has pt benefit
        • Radiographer/ dentist
      • Operator
        • Radiographer/ Dentist
      • Optimisation
        • ALARP
          • Controlled area
            • Within 1.5m of X-ray tube and patient in all other directions
      • Never event
        • law requires RPS to contact RPA to see if need to report this to CQC as radiation accident
        • e.g
          • Wrong patient
          • Wrong tooth
      • Limitation
    • New regulations
      • Specifically requires justification of exposures to carers or comforters
    • Department of health responsible
    • Report to CQC
  3. Grading according to FGDP guidelines

    • Grade 1 = excellent, no errors of exposure/positioning/processing (want >70%)
    • Grade 2 = = diagnostically acceptable, some errors of exposure/positioning/processing but don’t detract from diagnostic utility (<20%)
    • Grade 3= unacceptable and need to repeat ie diagnostically unacceptable (<10%)
      • For all grade 3 must record date, nature of error, known/suspected cause of error, no of repeats taken, total no taken during same period
        • Do an audit of IRMER
  4. X-ray viewing

    • May take up to 30% demineralisation to occur before caries visible radiographically
    • Don’t mistake cervical burnout space between enamel and bone overlying tooth will appear more radiolucent than enamel or bone-tooth combination
    • Must note any changes of lamina dura in radiographs
  5. Pregnancy

    • Can have dental X-rays but wear a lead apron
      • avoid x-rays in abdomen area
    • Limit before the 9 weeks
    • 6-9 weeks is the worst
  6. Radiation incident reports

    • Equipment failure
    • Geographical miss or wrong anatomy
    • Near miss
    • Overexposure
    • pt was not intended to receive exposure

Informações

Descrição
Radiology Mapa Mental sobre Rules & Regulations Radiology, criado por Zainab Patel em 01-02-2020.
Criado por
Zainab Patel
Visualizações
4
Avaliação

Fale Conosco

Sobre o que é sua mensagem?

O que a gente deve adicionar?