EPA 608 practice test: Core, Type I, II, III and Universal
Take a free 15-question check, see which topics to fix first and learn the rule behind every answer.
- topics covered, 246 explained questions
- 21
- questions on the Universal exam
- 100
- score needed to pass closed-book tests
- 70%
Quick check
Unlock 94 more free questions
Make a free account to keep going. We save your score by topic, so you can pick up where you left off. Your answers so far are kept.
Already have an account? Sign in
How to prepare
-
Find your weak spots Free
-
Learn the rule, not the answer Free account
-
18 questionsOzone and refrigerant types Ozone depletion and the differences between CFC, HCFC and HFC refrigerants.
-
12 questionsClean Air Act and venting Montreal Protocol, phaseouts, the venting prohibition and which substitutes are exempt.
-
11 questionsSection 608 rules Technician types, certified equipment, reclaim before resale, sales restriction, apprentices.
-
8 questionsSubstitutes and oils Retrofits with SNAP-acceptable substitutes and recovering HCFC-22 first.
-
12 questionsCycle, gauges, leak checks The refrigeration cycle, choosing gauges and hoses, and dry nitrogen for pressure tests.
-
11 questionsRecover, recycle, reclaim The three R's, recovery techniques, dehydration and keeping refrigerants separate.
-
18 questionsSafety, cylinders, shipping Oxygen displacement, frostbite, PPE, yellow-and-gray cylinders, 80 percent fill and DOT labels.
-
15 questionsSmall appliance recovery rules 80 and 90 percent recovery, four inches of mercury, final processor statements and records.
-
21 questionsSmall appliance techniques Access valves, inoperative compressors and using recovery equipment as directed.
-
5 questionsType I safety Toxic decomposition products, PPE, cylinder rules and nitrogen for leak tests.
-
13 questionsHigh-pressure leak detection Leak test before charging, use a regulator with nitrogen, never oxygen or compressed air.
-
10 questionsLeak repair rules Trigger leak rates, 30-day repairs, verification tests, retrofit plans, records and reports.
-
13 questionsType II recovery techniques Controlled heat, clearing the machine between refrigerants, low-loss fittings and pressure checks.
-
9 questionsEvacuation requirements Evacuating high-pressure appliances to the right level, liquid included, and verifying it.
-
12 questionsHigh-pressure refrigeration How high-pressure systems work and the pressure and temperature behavior you need for service.
-
4 questionsType II safety Safe handling of refrigerants, cylinders and pressurized systems on high-pressure equipment.
-
12 questionsLow-pressure leak detection Finding leaks in low-pressure systems, and the methods that suit them.
-
5 questionsType III leak repair Leak repair requirements as they apply to low-pressure appliances.
-
16 questionsRecovery and recharging Recovery and recharging techniques for low-pressure appliances.
-
12 questionsLow-pressure evacuation Evacuation requirements before opening or disposing of low-pressure appliances.
-
9 questionsPurge units and safety Purge units, pressure-temperature relationships and safe working on low-pressure chillers.
-
-
EPA 608 Prep Pass
Walk in ready for your EPA 608
Free shows your weak topics. The Prep Pass brings back your misses until you get them right.
- All 246 questions across 21 topics
- Full timed mock exams: 100 questions in 2 h
- Mistakes review: practice what you got wrong
- Your progress saved on phone and computer
US$9.99
Get your Prep Pass · US$9.99 -
Stop repeating mistakes Prep Pass
-
Target your weak spot Prep Pass
-
Rehearse the full test Prep Pass
EPA 608 at a glance
The test
Closed book, proctored
Questions
50 per type, 100 Universal
Time
Not set by EPA
Pass mark
70%
Validity
Does not expire
Sample EPA 608 questions
1. Which substance released from CFCs destroys stratospheric ozone?
- Hydrogen atoms
- Chlorine atoms
- Carbon atoms
- Fluorine atoms
Answer: B. Chlorine atoms
CFCs can release chlorine atoms in the stratosphere. Those atoms deplete the ozone layer.
- Hydrogen atoms: Hydrogen is not the ozone-depleting atom released from CFCs.
- Carbon atoms: Carbon is not the ozone-depleting atom identified in CFCs.
- Fluorine atoms: Fluorine is not the ozone-depleting atom identified in CFCs.
Source: US EPA, Section 608 Technician Certification Test Topics page: topic lists for Core, Type 1, Type 2 and Type…, Core test: Environmental Impacts
2. A CFC refrigerant reaches the stratosphere. What can break it down and release chlorine atoms?
- Heat from the troposphere
- Moisture in the atmosphere
- Pressure in the stratosphere
- Strong ultraviolet light
Answer: D. Strong ultraviolet light
Strong ultraviolet light breaks down CFCs in the stratosphere. This releases chlorine atoms that deplete ozone.
- Heat from the troposphere: CFCs are stable in the troposphere; heat there is not the mechanism described.
- Moisture in the atmosphere: Atmospheric moisture is not the mechanism described.
- Pressure in the stratosphere: Stratospheric pressure is not the mechanism described.
Source: US EPA, Section 608 Technician Certification Test Topics page: topic lists for Core, Type 1, Type 2 and Type…, Core test: Environmental Impacts
3. A technician is disposing of an appliance containing a non-exempt substitute refrigerant. How does the scope of EPA’s refrigerant recycling and emissions reduction rules apply?
- It covers servicing the appliance but not disposing of it.
- It covers disposal of the appliance containing the substitute refrigerant.
- It covers disposal only when the appliance contains a class I refrigerant.
- It covers disposal only when the appliance contains a class II refrigerant.
Answer: B. It covers disposal of the appliance containing the substitute refrigerant.
The refrigerant recycling and emissions reduction rules apply to people disposing of appliances containing non-exempt substitute refrigerants. The rules also cover appliances containing class I or class II refrigerants.
- It covers servicing the appliance but not disposing of it: The rules cover disposal as well as servicing.
- It covers disposal only when the appliance contains a class I refrigerant: Coverage is not limited to appliances containing class I refrigerants.
- It covers disposal only when the appliance contains a class II refrigerant: Coverage is not limited to appliances containing class II refrigerants.
Source: 40 CFR Part 82, Subpart F, eCFR, § 82.150 Purpose and scope.
4. A technician is servicing a commercial refrigeration system. Which refrigerant is exempt from the venting prohibition in this application?
- R-22 refrigerant
- R-134a refrigerant
- R-12 refrigerant
- Ammonia refrigerant
Answer: D. Ammonia refrigerant
Ammonia is exempt from the venting prohibition when used in commercial refrigeration. The exemption depends on the refrigerant and its application.
- R-22 refrigerant: R-22 is not listed as an exempt substitute.
- R-134a refrigerant: R-134a is not listed as an exempt substitute.
- R-12 refrigerant: R-12 is not listed as an exempt substitute.
Source: 40 CFR Part 82, Subpart F, eCFR, § 82.154 Prohibitions.
5. A manufacturer changes a certified recovery machine’s design in a way that could affect its ability to meet certification standards. What must happen before the altered machine is considered certified?
- The manufacturer must document the design change.
- The altered design must pass certification testing.
- A technician must verify the machine’s pressure gauge.
- An importer must register the altered machine.
Answer: B. The altered design must pass certification testing.
A change that could affect compliance requires the altered design to be resubmitted for certification testing. The equipment is considered uncertified until it is tested and shown to meet the standards.
- The manufacturer must document the design change: Documentation alone does not establish certification of the altered design.
- A technician must verify the machine’s pressure gauge: Checking the gauge does not replace certification testing of the altered design.
- An importer must register the altered machine: Registration by an importer does not replace certification testing.
Source: 40 CFR Part 82, Subpart F, eCFR, § 82.158 Standards for recovery and/or recycling equipment.
6. A shop uses a recovery machine manufactured in 2005 to service a commercial appliance that is not a small appliance. Who must certify the machine's evacuation capability?
- The appliance manufacturer
- An approved equipment testing organization
- The refrigerant reclaimer
- A certified service technician
Answer: B. An approved equipment testing organization
The machine must be certified by an approved equipment testing organization for its ability to achieve the specified evacuation level. This certification establishes that the equipment meets the applicable testing conditions.
- The appliance manufacturer: The appliance manufacturer is not the required certifying organization.
- The refrigerant reclaimer: A refrigerant reclaimer is not the required equipment certifier.
- A certified service technician: A technician's certification does not certify the equipment.
Source: 40 CFR Part 82, Subpart F, eCFR, § 82.158 Standards for recovery and/or recycling equipment. (part 2)
7. A homeowner asks whether a substitute can simply be added to an R-22 system without changing any components. What should the technician explain?
- A substitute can always be added without changes.
- A substitute requires only a new refrigerant label.
- A substitute can be added if the filter is clean.
- A substitute generally requires system component changes.
Answer: D. A substitute generally requires system component changes.
There is no drop-in replacement for R-22. Alternative refrigerants generally need changes to system components to work well.
- A substitute can always be added without changes: Substitutes are not universally usable without changes.
- A substitute requires only a new refrigerant label: A label alone does not address component changes.
- A substitute can be added if the filter is clean: A clean filter does not eliminate the need for component changes.
Source: US EPA, Section 608 Technician Certification Test Topics page: topic lists for Core, Type 1, Type 2 and Type…, Core test: Substitute Refrigerants and oils
What changed, and when
Leak repair rules apply only to appliances using ozone-depleting refrigerants, under the 2020 rule.
EPA last updated its Test Topics page. It still follows the CFC and HCFC outline, and HFC rules under the AIM Act (40 CFR Part 84) are not in the test topics.
How these questions are made
Checked by a second review
Checked by a second review
Resitting, or using old notes?
EPA says Section 608 credentials do not expire, so there is no renewal. If you are resitting, retake rules are set by the certifying organization, not by EPA, so check with the one you booked.
If your notes are older than April 2020, check the leak repair rules again: they now apply only to ozone-depleting refrigerants. The test topics still follow the CFC and HCFC outline.
Frequently asked questions
What is the EPA 608 certification?
It is the certification US technicians need to maintain, service, repair or dispose of stationary refrigeration and air-conditioning equipment under Section 608 of the Clean Air Act. It has four parts: Core, Type I, Type II and Type III.
What are Type I, II, III and Universal?
Type I covers small appliances, Type II high- and very-high-pressure appliances, and Type III low-pressure appliances. Universal means you have passed all of them.
How many questions are on the EPA 608 test?
Each test has 25 Core questions plus 25 for each type taken, so one type is 50 questions. Universal is 100 questions, taken at once or by combining separate passes.
Is the EPA 608 test changing in 2027?
Yes, the question bank is. Tests from the current bank are accepted only until 1 January 2027. The revised bank has about 400 questions in the same four sections (Core, Type I, II and III) and the same format, and adds general questions on A2L and A3 refrigerants such as R-32, R-454B and R-1234yf; outdated questions are dropped. If you are already certified, you do not need to retest. The questions here follow the current bank, so if you test on or after 1 January 2027, also study the A2L and A3 safety basics. Source: ACHR News, 19 September 2026, reporting the ESCO Institute.
What is the passing score for EPA 608?
The pass mark is 70 percent for the closed-book Type I, II, III and Universal tests. The mail-in Type I test needs 84 percent and cannot count toward Universal.
How long is the EPA 608 exam?
EPA does not set a time limit. Each certifying organization sets its own, so check with the one you book through.
Is the EPA 608 test open book?
The standard tests are closed book and proctored, with photo ID checked. Only Type I may be taken as a mail-in open-book test, and that version cannot count toward Universal.
Does EPA 608 certification expire?
No. EPA says the credentials do not expire.
How much does the EPA 608 test cost, and where do I take it?
EPA charges no fee, but certifying organizations may charge reasonable fees, so the price depends on who you book with. Choose any EPA-approved certifying organization from the list on epa.gov.