Exams · US
EPA 608 Core Practice Questions: Clean Air Act and Venting
Montreal Protocol, phaseouts, the venting prohibition and which substitutes are exempt.
Updated 17 November 2026 for the current EPA rules and Test Topics
Key facts
The Montreal Protocol is an international agreement to phase out substances that deplete the stratospheric ozone layer.
US EPA, Homeowners and Consumers: Frequently Asked Questions, Homeowners and Consumers: Frequently Asked Questions (ODS phaseout)
U.S. production and import of CFCs were banned beginning January 1, 1996, subject to exemptions.
US EPA, Phaseout of Class I Ozone-Depleting Substances, Phaseout of Class I Ozone-Depleting Substances
U.S. production and import of HCFC-22, also called R-22, ended January 1, 2020.
US EPA, Phaseout of Class II Ozone-Depleting Substances, Phaseout of Class II Ozone-Depleting Substances (part 2)
Existing R-22 air conditioners may remain in use and be serviced with recovered and properly reclaimed R-22.
US EPA, Homeowners and Consumers: Frequently Asked Questions, Homeowners and Consumers: Frequently Asked Questions (ODS phaseout) (part 2)
Do not knowingly vent or release refrigerant while maintaining, servicing, repairing, or disposing of refrigeration or air-conditioning equipment, unless an exemption applies.
40 CFR Part 82, Subpart F, eCFR, § 82.154 Prohibitions.
The venting prohibition covers non-exempt substitute refrigerants, including HFCs, as well as ozone-depleting refrigerants.
US EPA, Regulatory Updates: Section 608 Refrigerant Management Regulations, Regulatory Updates: Section 608 Refrigerant Management Regulations (part 2)
Do not knowingly release ozone-depleting refrigerant or a non-exempt substitute after recovering it from an appliance.
40 CFR Part 82, Subpart F, eCFR, § 82.154 Prohibitions. (part 2)
De minimis releases during good-faith recovery or recycling are permitted only when applicable regulatory practices and equipment requirements are observed.
40 CFR Part 82, Subpart F, eCFR, § 82.154 Prohibitions. (part 2)
Refrigerant releases during normal operation, such as leaks or mechanical purging, are permitted, subject to applicable leak repair requirements.
US EPA, Prohibition on Venting Refrigerants, Prohibition on Venting Refrigerants
Carbon dioxide, nitrogen, and water are exempt from the venting prohibition in any application; other substitutes are exempt only in specified end uses.
40 CFR Part 82, Subpart F, eCFR, § 82.154 Prohibitions.
Propane is exempt in specified equipment, including stand-alone retail food refrigerators and freezers and household refrigerators and freezers.
40 CFR Part 82, Subpart F, eCFR, § 82.154 Prohibitions.
Isobutane and R-441A are exempt in specified equipment, including household refrigerators and freezers and stand-alone retail food refrigerators and freezers.
40 CFR Part 82, Subpart F, eCFR, § 82.154 Prohibitions. (part 2)
Sample questions
1. A technician is disposing of an appliance containing a non-exempt substitute refrigerant. How does the scope of EPA’s refrigerant recycling and emissions reduction rules apply?
- It covers servicing the appliance but not disposing of it.
- It covers disposal of the appliance containing the substitute refrigerant.
- It covers disposal only when the appliance contains a class I refrigerant.
- It covers disposal only when the appliance contains a class II refrigerant.
Answer: B. It covers disposal of the appliance containing the substitute refrigerant.
The refrigerant recycling and emissions reduction rules apply to people disposing of appliances containing non-exempt substitute refrigerants. The rules also cover appliances containing class I or class II refrigerants.
- It covers servicing the appliance but not disposing of it: The rules cover disposal as well as servicing.
- It covers disposal only when the appliance contains a class I refrigerant: Coverage is not limited to appliances containing class I refrigerants.
- It covers disposal only when the appliance contains a class II refrigerant: Coverage is not limited to appliances containing class II refrigerants.
Source: 40 CFR Part 82, Subpart F, eCFR, § 82.150 Purpose and scope.
2. A technician is servicing a commercial refrigeration system. Which refrigerant is exempt from the venting prohibition in this application?
- R-22 refrigerant
- R-134a refrigerant
- R-12 refrigerant
- Ammonia refrigerant
Answer: D. Ammonia refrigerant
Ammonia is exempt from the venting prohibition when used in commercial refrigeration. The exemption depends on the refrigerant and its application.
- R-22 refrigerant: R-22 is not listed as an exempt substitute.
- R-134a refrigerant: R-134a is not listed as an exempt substitute.
- R-12 refrigerant: R-12 is not listed as an exempt substitute.
Source: 40 CFR Part 82, Subpart F, eCFR, § 82.154 Prohibitions.
3. What environmental problem does the Montreal Protocol address by phasing out substances such as CFCs?
- Acidification of surface water
- Formation of ground-level ozone
- Contamination of drinking water
- Depletion of stratospheric ozone
Answer: D. Depletion of stratospheric ozone
CFCs can reach the stratosphere and deplete the ozone layer. The ozone layer helps protect people from harmful ultraviolet radiation.
- Acidification of surface water: Surface-water acidification is not the problem described for CFCs.
- Formation of ground-level ozone: Ground-level ozone formation is different from stratospheric ozone depletion.
- Contamination of drinking water: Drinking-water contamination is not the problem described for CFCs.
Source: US EPA, Homeowners and Consumers: Frequently Asked Questions, Homeowners and Consumers: Frequently Asked Questions (ODS phaseout)
4. A homeowner wants to retrofit an HCFC-22 air conditioner to use a non-ozone-depleting refrigerant. What should happen before the alternative is added?
- Recover the remaining HCFC-22 from the system.
- Mix the remaining HCFC-22 with the alternative.
- Vent the remaining HCFC-22 outdoors.
- Leave the remaining HCFC-22 in the system.
Answer: A. Recover the remaining HCFC-22 from the system.
A Section 608-certified technician should recover the remaining HCFC-22 before adding the alternative. This clears the original refrigerant from the system before conversion.
- Mix the remaining HCFC-22 with the alternative: The refrigerants should not be mixed during the conversion.
- Vent the remaining HCFC-22 outdoors: The remaining HCFC-22 should be recovered, not vented.
- Leave the remaining HCFC-22 in the system: The remaining HCFC-22 should be recovered before the alternative is added.
Source: US EPA, Homeowners and Consumers: Frequently Asked Questions, Homeowners and Consumers: Frequently Asked Questions (ODS phaseout) (part 3)