Exams · US
EPA 608 practice questions: Type II recovery techniques
Controlled heat, clearing the machine between refrigerants, low-loss fittings and pressure checks.
Updated 17 November 2026 for the current EPA rules and Test Topics
Key facts
Recover liquid refrigerant first when practical to speed up recovery, then recover the remaining vapor.
US EPA, Section 608 Technician Certification: Test Topics, Type 2 (High-Pressure) test: Recovery Techniques
Chilling the recovery vessel can speed recovery by lowering its pressure.
US EPA, Section 608 Technician Certification: Test Topics, Type 2 (High-Pressure) test: Recovery Techniques
Warming the appliance can speed recovery by increasing refrigerant pressure and helping liquid refrigerant vaporize.
US EPA, Section 608 Technician Certification: Test Topics, Type 2 (High-Pressure) test: Recovery Techniques
Use controlled heat rather than an open flame when warming an appliance or recovery vessel.
US EPA, Section 608 Technician Certification: Test Topics, Type 2 (High-Pressure) test: Recovery Techniques
Before changing refrigerants, clear the recovery machine and hoses of the previous refrigerant according to the equipment manufacturer's instructions.
US EPA, Section 608 Technician Certification: Test Topics, Type 2 (High-Pressure) test: Recovery Techniques
Use a properly identified recovery cylinder for each refrigerant to avoid mixing refrigerants.
US EPA, Section 608 Technician Certification: Test Topics, Type 2 (High-Pressure) test: Recovery Techniques
Use low-loss hose fittings to reduce refrigerant emissions when disconnecting recovery equipment.
US EPA, Section 608 Technician Certification: Test Topics, Type 2 (High-Pressure) test: Recovery Techniques
After reaching the required recovery vacuum, isolate the appliance and wait a few minutes while watching its pressure.
US EPA, Section 608 Technician Certification: Test Topics, Type 2 (High-Pressure) test: Recovery Techniques
A pressure rise after isolation can indicate liquid refrigerant remaining in the appliance or refrigerant trapped in the oil.
US EPA, Section 608 Technician Certification: Test Topics, Type 2 (High-Pressure) test: Recovery Techniques
If pressure rises after isolation, resume recovery and repeat the pressure check after reaching the required vacuum.
US EPA, Section 608 Technician Certification: Test Topics, Type 2 (High-Pressure) test: Recovery Techniques
Sample questions
1. A technician wants to shorten the recovery time for a high-pressure appliance. Which approach should the technician use?
- Recover vapor first, then liquid.
- Alternate between liquid and vapor throughout.
- Recover liquid first, then vapor.
- Recover vapor only, leaving the liquid behind.
Answer: C. Recover liquid first, then vapor.
Recovering liquid at the beginning speeds up the recovery process. Vapor can be recovered afterward.
- Recover vapor first, then liquid: Starting with vapor does not provide the speed advantage of liquid-first recovery.
- Alternate between liquid and vapor throughout: Alternating does not prioritize liquid at the beginning.
- Recover vapor only, leaving the liquid behind: Leaving liquid behind does not complete recovery.
Source: US EPA, Section 608 Technician Certification Test Topics page: topic lists for Core, Type 1, Type 2 and Type…, Type 2 (High-Pressure) test: Recovery Techniques
2. Two comparable recovery jobs use different sequences. One starts with liquid recovery; the other starts with vapor recovery. Which sequence is expected to finish faster?
- The vapor-first sequence.
- Either sequence takes the same time.
- Alternating liquid and vapor from the start.
- The liquid-first sequence.
Answer: D. The liquid-first sequence.
Starting with liquid recovery speeds up the process compared with starting with vapor. The sequence therefore affects recovery time.
- The vapor-first sequence: Starting with vapor misses the speed advantage of liquid-first recovery.
- Either sequence takes the same time: The recovery sequence can affect the time required.
- Alternating liquid and vapor from the start: The comparison is between liquid-first and vapor-first recovery, not alternating.
Source: US EPA, Section 608 Technician Certification Test Topics page: topic lists for Core, Type 1, Type 2 and Type…, Type 2 (High-Pressure) test: Recovery Techniques
3. An apprentice begins a recovery job by taking vapor first. The supervisor wants a faster sequence on the next comparable job. What change should the supervisor recommend?
- Start with vapor and alternate to liquid.
- Start with liquid before recovering vapor.
- Start with vapor and continue until finished.
- Start with liquid but leave vapor in the appliance.
Answer: B. Start with liquid before recovering vapor.
Taking liquid first speeds up recovery. The technician can then recover the remaining vapor.
- Start with vapor and alternate to liquid: Starting with vapor does not prioritize the faster liquid-first sequence.
- Start with vapor and continue until finished: Vapor-first recovery misses the liquid-first speed advantage.
- Start with liquid but leave vapor in the appliance: Leaving vapor behind does not complete recovery.
Source: US EPA, Section 608 Technician Certification Test Topics page: topic lists for Core, Type 1, Type 2 and Type…, Type 2 (High-Pressure) test: Recovery Techniques
4. A technician plans to recover both liquid and vapor from an appliance. To speed up the job, when should liquid recovery be scheduled?
- After all vapor recovery is finished.
- At the beginning of the process.
- Only after pressure stops rising.
- At intervals throughout vapor recovery.
Answer: B. At the beginning of the process.
Liquid recovery at the beginning speeds up the overall process. The technician can recover vapor afterward.
- After all vapor recovery is finished: Delaying liquid recovery gives up the benefit of taking it first.
- Only after pressure stops rising: Waiting for pressure to stop rising does not prioritize initial liquid recovery.
- At intervals throughout vapor recovery: Intermittent liquid recovery does not ensure it is taken first.
Source: US EPA, Section 608 Technician Certification Test Topics page: topic lists for Core, Type 1, Type 2 and Type…, Type 2 (High-Pressure) test: Recovery Techniques