  1. 1.1 Health and Safety

  2. 1.2 Liquids and Solutions

    • The use of: linear and log dilution series; standard curve for determination of an unknown; buffers to control pH; colorimeter to quantify concentration.
    • Measuring Liquids
    • Dilution Series
      • From a stock solution
      • Linear - 0.0, 0.2, 0.4, 0.6
      • Logarithmic - 1, 0.1, 0.01, 0.001
    • Colourimitry
      • Measures the absorbance of specific wavelengths of light by a solution.
    • Determining an Unknown Concentration
      • Standard Curve
  3. 1.3 Separation Techniques

    • Centrifugation to separate pellet and supernatant of differing density. Paper, thin layer and affinity chromatography for amino acids and proteins. Protein electrophoresis uses current flowing through a buffer to separate proteins. Size and charge are factors affecting protein migration in a gel. Proteins can be separated using pH; at their iso-electric point they have an overall neutral charge and precipitate out of solution.
    • Protein electrophoresis
      • Separates proteins based upon their charge and/or size/shape.
    • Iso-electric point
      • At their iso-electric point, proteins have an overall neutral charge and precipitate out of solution.
      • Proteins carry an overall positive charge at a pH below their isoelectric point, a negative charge at a pH above their isoelectric point.
    • Paper, thin layer and affinity chromatography
      • Paper
        • Stationary phase is a strip of chromatography paper.
        • Any components of the mixture which are polar will bond quickly. Non-polar components of the mixture will not bind as quickly
      • Affinity
        • Affinity chromatography relies on binding between a protein and ligand
        • The target protein can then be stripped from the support, resulting in its separation and purification
      • Thin Layer
        • TLC is similar to paper chromatography, but TLC uses a strip of absorbent material, such as silica gel.
  4. 1.4 Antibody Technique

    • Detection and identification of specific proteins. Immunoassay techniques use antibodies linked to reporter enzymes to cause a colour change in the presence of a specific antigen. Fluorescent labelled antibodies in protein blotting and immunohistochemical staining of tissue. Monoclonal antibodies are produced using hybridomas formed from the fusion of a B lymphocyte with a myeloma cell using polyethylene glycol (PEG).
    • Immunoassay
      • Antibodies can be used to detect both the presence and concentration of a protein within a solution.
      • Linked with an identifiable label
      • ELISA - enzyme-linked immunosorbent assay
        • 1. The antigen is allowed to bind to the surface of a multiwell plate. 2. A primary antibody is added to the well and allowed to bind to the antigen. 3. A secondary antibody, linked to a reporter enzyme, is then added which binds to the primary antibody. 4. A colour-producing substrate is added to the well and a colour is allowed to develop. Colourless = negative result, colour change = positive result
    • Protein blotting
    • Immunohistochemistry
      • Commonly used in the diagnosis of diseases such as cancer because it can identify abnormal gene expression within cells.
      • Advantage is that it shows exactly where a certain protein is being expressed in a tissue sample.
    • Monoclonal antibodies
      • Hybridomas are formed by fusion of a B lymphocyte with a myeloma cell using polyethyleneglycol (PEG)
  5. 1.5 Microscopy

    • Use of bright field to examine whole organisms, parts of organisms or thin sections of dissected tissue. Fluorescence microscopy allows particular protein structures to be visualised.
    • Bright field and fluorescence microscopy
      • A sample is mounted on a slide and illuminated from below. The image of the sample that is produced is usually darker than the background which appears bright.
      • In fluorescence microscopy, specific protein structures have fluorescent markers added to them.
    • Haemocytometer
      • A haemocytometer allows an estimation of the concentration of cells in a sample to be made. A haemocytometer resembles a microscope slide, but has a grid made up of perpendicular lines (similar to graph paper) etched into the glass.
    • Flow cytometry
      • Flow cytometry allows scientists to detect, count and analyse cells as they flow past a detector in solution, one by one.
  6. 1.6 Aseptic Technique & Cell Culture

    • Complex media containing growth factors from serum for animal cell lines. Lifetime of primary cell lines and cancer cell lines in culture. Use of growth regulators in plant tissue culture.
    • Asceptic Technique
      • A technique which prevents contamination of people / cell cultures / environment by living microorganisms
    • Cell Culture
      • Inoculum, explants or cells can be added to agar plates or nutrient broths and grown in the lab
      • Animal cells have a limited lifespan (primary cell lines) but cancerous cells can be used to create immortal cell lines
      • Specific growth factors from serums (foetal bovine serum) must be added for growth of animal cells in culture
      • Plant cells also require specific growth factors eg auxin, cytokinins

Imágenes y archivos del mapa

  • Unit 1 - Topic 1 - Laboratory techniques for biologists

Información

Descripción
Highers Biology Mapa Mental sobre Unit 1 - Topic 1 - Laboratory techniques for biologists, creado por Morgan Butler el 12/01/2018.
Creado por
Morgan Butler
Visitas
2
Valoración

Escríbenos

¿Sobre qué es tu mensaje?

¿Qué deberíamos añadir?