O GoConqr está de visual novo! Conte para nós o que você achou.

Quiz

HVAC Practive midterm 56

Rudy Robertson 56 perguntas

Fazer o quiz

Perguntas do quiz (56)

  1. 1On a standing pilot gas furnace the thermocouple must be replaced when?
    1. Aits not positioned properly
    2. BThe millivolt reading is 28 or above
    3. Cthe millivolt reading is 22 or below
    4. Dthe tip of the thermocouple is in the tip if the pilot flame is 3/8
  2. 2natural gas pressure at the main line is recorded at 7" WC (water column), But at the gas manifold it reads 1.5 WC. What is most likely to be the cause of this?
    1. AA defective main line regulator
    2. BToo large of a gas valve
    3. Cplugged burner orifices
    4. DA defective pressure regulator on the gas valve
  3. 3A technician servicing a gas fired furnace notices that only four out of five ribbon burners are firing simultaneously . What could be the problem with the system?
    1. AToo much gas pressure
    2. BToo little gas pressure
    3. CBurners not aligned correctly
    4. DA defective gas valve
  4. 4Technician A says if a combination gas valve needs to be replaced if there are 24 volts present to the gas valve and it will not open.

    Technician B says that if a combination gas valve has a new thermocouple and the pilot will not stay lit the gas valve needs to be replaced.

    Which technician is correct?
    1. ATech A
    2. BTECH B
    3. CBoth are right
    4. DBoth are wrong
  5. 5What should be the first step that a technician should take if the gas pressure at the manifold is too high?
    1. Aadjust the pressure regulator clockwise
    2. Badjust the pressure regulator counter clockwise
    3. Creplace the pressure regulator
    4. Dreplace the combination gas valve
  6. 6If the glame is lifting off the burner port what should the technician do to correct this problem?
    1. AAdjust the primary air by closing the air shutter
    2. Badjust the primary air by opening the air shutter
    3. Creplace the burner
    4. Ddecrease the min gas pressure.
  7. 7a step down transformer is reading 0 ohms at its secondary winding. what is the possible cause of this problem?
    1. AAn open primary winding
    2. Ban open secondary winding
    3. CA shorted primary winding
    4. DA shorter secondary winding
  8. 8when a fan centre relay needs to be tested for 124 volts, what two terminals are used when measuring for transformer output voltages?
    1. ATerminals "R" and "W"
    2. BTerminals "R" and "G"
    3. CTerminals "R" and "Y"
    4. DTerminals "R and "C'
  9. 9On a call for heat what two terminals should be closed on the thermostat?
    1. ATerminals "R" and "W"
    2. BTerminals "R" and "G"
    3. CTerminals "R" and "Y"
    4. DTerminals "R" and "C"
  10. 10when a thermostat sub base fan selector switch is moved to the fan "ON" postition, what two terminals will close in the thermostat.
    1. ATerminals "R" and "W"
    2. BTerminals "R" and "G"
    3. CTerminals "R" and "Y"
    4. DTerminals "R" and "C"